Search Results (807 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2024-8936 1 Schneider-electric 1 Modicon M340 2026-04-15 6.5 Medium
CWE-20: Improper Input Validation vulnerability exists that could lead to loss of confidentiality of controller memory after a successful Man-In-The-Middle attack followed by sending a crafted Modbus function call used to tamper with memory.
CVE-2024-8518 1 Schneider-electric 1 Zelio Soft 2 2026-04-15 3.3 Low
CWE-20: Improper Input Validation vulnerability exists that could cause a crash of the Zelio Soft 2 application when a specially crafted project file is loaded by an application user.
CVE-2024-8935 1 Schneider-electric 3 Modicon M340 Bmxp341000, Modicon Mc80 Bmkc8020301, Modicon Momentum Unity M1e Processor 2026-04-15 7.5 High
CWE-290: Authentication Bypass by Spoofing vulnerability exists that could cause a denial of service and loss of confidentiality and integrity of controllers when conducting a Man-In-The-Middle attack between the controller and the engineering workstation while a valid user is establishing a communication session. This vulnerability is inherent to Diffie Hellman algorithm which does not protect against Man-In-The-Middle attacks.
CVE-2024-10498 1 Schneider-electric 1 Powerlogic Hdpm6000 2026-04-15 6.5 Medium
CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists that could allow an unauthorized attacker to modify configuration values outside of the normal range when the attacker sends specific Modbus write packets to the device which could result in invalid data or loss of web interface functionality.
CVE-2025-13905 1 Schneider-electric 2 Ecostruxure Process Expert, Ecostruxure Process Expert For Aveva System Platform 2026-04-15 N/A
CWE-276: Incorrect Default Permissions vulnerability exists that could cause privilege escalation through the reverse shell when one or more executable service binaries are modified in the installation folder by a local user with normal privilege upon service restart.
CVE-2025-11566 1 Schneider-electric 1 Powerchute Serial Shutdown 2026-04-15 N/A
CWE-307: Improper Restriction of Excessive Authentication Attempts vulnerability exists that would allow an attacker on the local network to gain access to the user account by performing an arbitrary number of authentication attempts with different credentials on the /REST/shutdownnow endpoint.
CVE-2025-8448 1 Schneider-electric 2 Ecostruxure Building Operation Enterprise Server, Ecostruxure Workstation 2026-04-15 N/A
CWE-200: Exposure of Sensitive Information to an Unauthorized Actor vulnerability exists that could cause unauthorized access to sensitive credential data when an attacker is able to capture local SMB traffic between a valid user within the BMS network and the vulnerable products.
CVE-2025-11739 1 Schneider-electric 2 Ecostruxure Power Monitoring Expert, Ecostruxure Power Operation With Advanced Reporting And Dashboards 2026-03-11 N/A
CWE‑502: Deserialization of Untrusted Data vulnerability exists that could cause arbitrary code execution with administrative privileges when a locally authenticated attacker sends a crafted data stream, triggering unsafe deserialization.
CVE-2025-13902 1 Schneider-electric 2 Modicon Controllers M241/m251, Modicon Controllers M258/lmc058 2026-03-11 N/A
CWE-79 Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists that could cause condition where authenticated attackers can have a victim’s browser run arbitrary JavaScript when the victim hovers over a maliciously crafted element on a web server containing the injected payload.
CVE-2025-13901 1 Schneider-electric 2 Modicon M241/m251, Modicon M262 2026-03-11 N/A
CWE-404 Improper Resource Shutdown or Release vulnerability exists that could cause partial Denial of Service on Machine Expert protocol when an unauthenticated attacker sends malicious payload to occupy active communication channels.
CVE-2025-13957 1 Schneider-electric 1 Struxureware Data Center Expert 2026-03-11 N/A
CWE-798: Use of Hard-coded Credentials vulnerability exists that could cause information disclosure and remote code execution when SOCKS Proxy is enabled, and administrator credentials and PostgreSQL database credentials are known. SOCKS Proxy is disabled by default.
CVE-2025-13844 1 Schneider-electric 1 Ecostruxure Power Build - Rapsody 2026-03-03 5.3 Medium
CWE-415: Double Free vulnerability exists that could cause heap memory corruption when the end user imports a malicious project file (SSD file) shared by the attacker into Rapsody.
CVE-2023-6407 2 Microsoft, Schneider-electric 6 Windows 10 1507, Windows 11 21h2, Windows Server 2016 and 3 more 2026-02-25 5.3 Medium
A CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists that could cause arbitrary file deletion upon service restart when accessed by a local and low-privileged attacker.
CVE-2018-1124 6 Canonical, Debian, Opensuse and 3 more 13 Ubuntu Linux, Debian Linux, Leap and 10 more 2025-12-18 7.8 High
procps-ng before version 3.3.15 is vulnerable to multiple integer overflows leading to a heap corruption in file2strvec function. This allows a privilege escalation for a local attacker who can create entries in procfs by starting processes, which could result in crashes or arbitrary code execution in proc utilities run by other users.
CVE-2018-1126 5 Canonical, Debian, Procps-ng Project and 2 more 13 Ubuntu Linux, Debian Linux, Procps-ng and 10 more 2025-12-17 N/A
procps-ng before version 3.3.15 is vulnerable to an incorrect integer size in proc/alloc.* leading to truncation/integer overflow issues. This flaw is related to CVE-2018-1124.
CVE-2014-5413 2 Aveva, Schneider-electric 2 Clearscada, Scada Expert Clearscada 2025-11-04 N/A
Schneider Electric StruxureWare SCADA Expert ClearSCADA 2010 R3 through 2014 R1 uses the MD5 algorithm for an X.509 certificate, which makes it easier for remote attackers to spoof servers via a cryptographic attack against this algorithm.
CVE-2014-5412 2 Aveva, Schneider-electric 2 Clearscada, Scada Expert Clearscada 2025-11-04 N/A
Schneider Electric StruxureWare SCADA Expert ClearSCADA 2010 R3 through 2014 R1 allows remote attackers to read database records by leveraging access to the guest account.
CVE-2014-5411 2 Aveva, Schneider-electric 2 Clearscada, Scada Expert Clearscada 2025-11-04 N/A
Multiple cross-site scripting (XSS) vulnerabilities in Schneider Electric StruxureWare SCADA Expert ClearSCADA 2010 R3 through 2014 R1 allow remote authenticated users to inject arbitrary web script or HTML via unspecified vectors.
CVE-2014-5407 1 Schneider-electric 1 Vampset 2025-11-03 N/A
Multiple stack-based buffer overflows in Schneider Electric VAMPSET 2.2.136 and earlier allow local users to cause a denial of service (application halt) via a malformed (1) setting file or (2) disturbance recording file.
CVE-2018-7841 1 Schneider-electric 1 U.motion Builder 2025-11-03 9.8 Critical
A SQL Injection (CWE-89) vulnerability exists in U.motion Builder software version 1.3.4 which could cause unwanted code execution when an improper set of characters is entered.