| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| Missing Authentication for Critical Function vulnerability in the mobile monitoring feature of Mitsubishi Electric GENESIS64 versions 10.97.2 and prior, Mitsubishi Electric ICONICS Suite versions 10.97.2 and prior, Mitsubishi Electric Hyper Historian versions 10.97.2 and prior, Mitsubishi Electric AnalytiX versions 10.97.2 and prior, Mitsubishi Electric MobileHMI versions 10.97.2 and prior, Mitsubishi Electric IoTWorX version 10.95, Mitsubishi Electric MC Works64 all versions, Mitsubishi Electric Iconics Digital Solutions GENESIS64 versions 10.97.2 and prior, Mitsubishi Electric Iconics Digital Solutions ICONICS Suite versions 10.97.2 and prior, Mitsubishi Electric Iconics Digital Solutions Hyper Historian versions 10.97.2 and prior, Mitsubishi Electric Iconics Digital Solutions AnalytiX versions 10.97.2 and prior, Mitsubishi Electric Iconics Digital Solutions MobileHMI versions 10.97.2 and prior, and Mitsubishi Electric Iconics Digital Solutions IoTWorX version 10.95 allows a remote unauthenticated attacker to bypass proper authentication and log in to the system when all of the following conditions are met: (1) Active Directory is used in the security setting (2) "Automatic log in" option is enabled in the security setting (3) The IcoAnyGlass IIS Application Pool is running under an Active Directory Domain Account. (4) The IcoAnyGlass IIS Application Pool account is included in GENESIS64, ICONCIS Suite, and MC Works64 Security and has permission to log in. |
| A vulnerability has been identified in Desigo CC (All versions if access from Installed Clients to Desigo CC server is allowed from networks outside of a highly protected zone), Desigo CC (All versions if access from Installed Clients to Desigo CC server is only allowed within highly protected zones). The affected server application fails to authenticate specific client requests. Modification of the client binary could allow an unauthenticated remote attacker to execute arbitrary SQL queries on the server database via the event port (default: 4998/tcp) |
| CWE-306: Missing Authentication for Critical Function vulnerability exists that could
cause exposure of private data when an already generated “logcaptures” archive is accessed
directly by HTTPS. |
| SEL BIOS packages prior to 1.3.49152.117 or 2.6.49152.98 allow a local attacker to bypass password authentication and change password-protected BIOS settings by importing a BIOS settings file with no password set. |
| Lua apps can be deployed, removed, started, reloaded or stopped without authorization via
AppManager. This allows an attacker to remove legitimate apps creating a DoS attack, read and write
files or load apps that use all features of the product available to a customer. |
| An issue in Plug n Play Camera com.ezset.delaney 1.2.0 allows a remote attacker to obtain sensitive information via the firmware update process. |
| An issue in Fermax Asia Pacific Pte Ltd com.fermax.vida 2.4.6 allows a remote attacker to obtain sensitve information via the firmware update process. |
| An issue in WoFit v.7.2.3 allows a remote attacker to obtain sensitive information via the firmware update process |
| An improper exception check in Palo Alto Networks Prisma Access Browser allows a low privileged user to prevent Prisma Access Browser from applying it's Policy Rules. This enables the user to use Prisma Access Browser without any restrictions. |
| The Amp’ed RF BT-AP 111 Bluetooth access point's HTTP admin interface does not have an authentication feature, allowing unauthorized access to anyone with network access. |
| The affected product allows unauthenticated access to Real Time Streaming Protocol (RTSP) services, which may allow an attacker unauthorized access to camera configuration information. |
| A vulnerability classified as problematic was found in Lucky LM-520-SC, LM-520-FSC and LM-520-FSC-SAM up to 20250321. Affected by this vulnerability is an unknown functionality. The manipulation leads to missing authentication. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way. |
| Webhood is a self-hosted URL scanner used analyzing phishing and malicious sites. Webhood's backend container images in versions 0.9.0 and earlier are subject to Missing Authentication for Critical Function vulnerability. This vulnerability allows an unauthenticated attacker to send a HTTP request to the database (Pocketbase) admin API to create an admin account. The Pocketbase admin API does not check for authentication/authorization when creating an admin account when no admin accounts have been added. In its default deployment, Webhood does not create a database admin account. Therefore, unless users have manually created an admin account in the database, an admin account will not exist in the deployment and the deployment is vulnerable. Versions starting from 0.9.1 are patched. The patch creates a randomly generated admin account if admin accounts have not already been created i.e. the vulnerability is exploitable in the deployment. As a workaround, users can disable access to URL path starting with `/api/admins` entirely. With this workaround, the vulnerability is not exploitable via network. |
| An authentication bypass vulnerability exists which allows an unauthenticated attacker to control administrator backup functions, leading to compromise of passwords, secrets, and application session tokens stored by the Unified PAM. |
| dectalk-tts is a Node package to interact with the aeiou Dectalk web API. In `dectalk-tts@1.0.0`, network requests to the third-party API are sent over HTTP, which is unencrypted. Unencrypted traffic can be easily intercepted and modified by attackers. Anyone who uses the package could be the victim of a man-in-the-middle (MITM) attack. The network request was upgraded to HTTPS in version `1.0.1`. There are no workarounds, but some precautions include not sending any sensitive information and carefully verifying the API response before saving it. |
| The embedded web server on the thermostat listed version ranges contain a vulnerability that allows unauthenticated attackers, either on the local area network or from the Internet via a router with port forwarding set up, to gain direct access to the thermostat's embedded web server and reset user credentials by manipulating specific elements of the embedded web interface. |
| The MCP inspector is a developer tool for testing and debugging MCP servers. Versions of MCP Inspector below 0.14.1 are vulnerable to remote code execution due to lack of authentication between the Inspector client and proxy, allowing unauthenticated requests to launch MCP commands over stdio. Users should immediately upgrade to version 0.14.1 or later to address these vulnerabilities. |
| A Missing Authentication for Critical Function issue affecting the HTTP service running on the DJI Mavic Mini 3 Pro on the standard port 80 could allow an attacker to enumerate and download videos and pictures saved on the drone internal or external memory without requiring any kind of authentication. |
| Improper control of framework service permissions with possibility of some sensitive device information leakage. |
| Improper handling of WiFi information by framework services can allow certain malicious applications to obtain sensitive information. |