Search Results (814 CVEs found)
| CVE | Vendors | Products | Updated | CVSS v3.1 |
|---|---|---|---|---|
| CVE-2026-14354 | 1 Schneider-electric | 1 Ecostruxure Cybersecurity Admin Expert | 2026-08-04 | N/A |
| CWE-522 Insufficiently Protected Credentials vulnerability exists that could cause authentication bypass and unauthorized credential modification, potentially leading to compromise of managed devices, when a local privileged attacker leverages weaknesses in the handling and protection of stored credentials within the application. | ||||
| CVE-2026-0667 | 1 Schneider-electric | 3 Remoteconnect, Scadapack 470, Scadapack 570 | 2026-08-04 | N/A |
| CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability that could cause arbitrary code execution, denial of service and loss of confidentiality & integrity when communicating over the Modbus TCP protocol. | ||||
| CVE-2021-22769 | 1 Schneider-electric | 2 Easergy T300, Easergy T300 Firmware | 2026-06-29 | 5.3 Medium |
| A CWE-552: Files or Directories Accessible to External Parties vulnerability exists in Easergy T300 with firmware V2.7.1 and older that could expose files or directory content when access from an attacker is not restricted or incorrectly restricted. | ||||
| CVE-2026-9717 | 1 Schneider-electric | 2 Powerlogic P7, Powerlogic P7 Firmware | 2026-06-26 | 7.2 High |
| CWE-78 Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability exists that could allow unauthorized execution of commands with elevated privileges, impacting system integrity, confidentiality, and availability when a privileged authenticated user interacts with a vulnerable network-exposed service. | ||||
| CVE-2026-9650 | 2 Schneider-electric, Schneider Electric | 6 Easylogic T150, Easylogic T150 Firmware, Saitel Dp and 3 more | 2026-06-26 | 7.5 High |
| CWE-522 Insufficiently Protected Credentials vulnerability that could cause unauthorized access and exposure of sensitive information when unauthenticated attacker accesses credentials stored within firmware or system files. With this credential an attacker could subsequently compromise the device if they have physical access to the device. | ||||
| CVE-2026-9651 | 2 Schneider-electric, Schneider Electric | 6 Easylogic T150, Easylogic T150 Firmware, Saitel Dp and 3 more | 2026-06-26 | 4.4 Medium |
| CWE-732 Incorrect Permission Assignment for Critical Resource vulnerability that could cause unauthorized disclosure of password hashes and potential account compromise when an attacker with privileged local access reads improperly protected system files. | ||||
| CVE-2026-9716 | 1 Schneider-electric | 2 Powerlogic P7, Powerlogic P7 Firmware | 2026-06-26 | 7.5 High |
| CWE-476 NULL Pointer Dereference vulnerability exists that could cause a denial-of-service condition, rendering the device’s HMI and configuration functionality unavailable when malformed requests are received over exposed network interfaces. | ||||
| CVE-2026-9718 | 1 Schneider-electric | 2 Powerlogic P7, Powerlogic P7 Firmware | 2026-06-26 | 6.5 Medium |
| CWE-617 Reachable Assertion vulnerability exists that could allow an authenticated attacker to trigger a denial-of-service condition, impacting system availability when a specially crafted request is sent to a vulnerable network-exposed service. | ||||
| CVE-2026-8045 | 1 Schneider-electric | 1 Struxureware Data Center Expert | 2026-06-09 | 6.5 Medium |
| CWE-611 Improper Restriction of XML External Entity Reference vulnerability exists that could cause information disclosure of server-side file contents when an attacker with a Data Center Expert user account submits crafted XML payloads to SOAP service endpoints. | ||||
| CVE-2017-6030 | 1 Schneider-electric | 6 Modicon M221, Modicon M221 Firmware, Modicon M241 and 3 more | 2026-06-04 | 6.5 Medium |
| A predictable value range from previous values issue was discovered in Schneider Electric Modicon PLCs Modicon M221, firmware versions prior to Version 1.5.0.0, Modicon M241, firmware versions prior to Version 4.0.5.11, and Modicon M251, firmware versions prior to Version 4.0.5.11. The affected products generate insufficiently random TCP initial sequence numbers that may allow an attacker to predict the numbers from previous values. This may allow an attacker to spoof or disrupt TCP connections. | ||||
| CVE-2017-6034 | 1 Schneider-electric | 2 Modbus, Modbus Firmware | 2026-06-04 | 9.8 Critical |
| An authentication bypass by capture-replay issue was discovered in Schneider Electric Modicon Modbus Protocol. Sensitive information is transmitted in cleartext in the Modicon Modbus protocol, which may allow an attacker to replay the following commands: run, stop, upload, and download. | ||||
| CVE-2019-10953 | 5 Abb, Phoenixcontact, Schneider-electric and 2 more | 20 Pm554-tp-eth, Pm554-tp-eth Firmware, Ilc 151 Eth and 17 more | 2026-06-04 | 7.5 High |
| ABB, Phoenix Contact, Schneider Electric, Siemens, WAGO - Programmable Logic Controllers, multiple versions. Researchers have found some controllers are susceptible to a denial-of-service attack due to a flood of network packets. | ||||
| CVE-2018-3639 | 12 Arm, Canonical, Debian and 9 more | 330 Cortex-a, Ubuntu Linux, Debian Linux and 327 more | 2026-05-29 | 5.5 Medium |
| Systems with microprocessors utilizing speculative execution and speculative execution of memory reads before the addresses of all prior memory writes are known may allow unauthorized disclosure of information to an attacker with local user access via a side-channel analysis, aka Speculative Store Bypass (SSB), Variant 4. | ||||
| CVE-2020-7566 | 1 Schneider-electric | 2 Modicon M221, Modicon M221 Firmware | 2026-05-29 | 7.1 High |
| A CWE-334: Small Space of Random Values vulnerability exists in Modicon M221 (all references, all versions) that could allow the attacker to break the encryption keys when the attacker has captured the traffic between EcoStruxure Machine - Basic software and Modicon M221 controller. | ||||
| CVE-2021-22788 | 1 Schneider-electric | 28 140cpu65150, 140cpu65150 Firmware, 140noc77101 and 25 more | 2026-05-29 | 7.5 High |
| A CWE-787: Out-of-bounds Write vulnerability exists that could cause denial of service when an attacker sends a specially crafted HTTP request to the web server of the device. Affected Product: Modicon M340 CPUs: BMXP34 (Versions prior to V3.40), Modicon M340 X80 Ethernet Communication Modules: BMXNOE0100 (H), BMXNOE0110 (H), BMXNOC0401, BMXNOR0200H RTU (All Versions), Modicon Premium Processors with integrated Ethernet (Copro): TSXP574634, TSXP575634, TSXP576634 (All Versions), Modicon Quantum Processors with Integrated Ethernet (Copro): 140CPU65xxxxx (All Versions), Modicon Quantum Communication Modules: 140NOE771x1, 140NOC78x00, 140NOC77101 (All Versions), Modicon Premium Communication Modules: TSXETY4103, TSXETY5103 (All Versions) | ||||
| CVE-2021-22787 | 1 Schneider-electric | 28 140cpu65150, 140cpu65150 Firmware, 140noc77101 and 25 more | 2026-05-29 | 7.5 High |
| A CWE-20: Improper Input Validation vulnerability exists that could cause denial of service of the device when an attacker sends a specially crafted HTTP request to the web server of the device. Affected Product: Modicon M340 CPUs: BMXP34 (Versions prior to V3.40), Modicon M340 X80 Ethernet Communication Modules: BMXNOE0100 (H), BMXNOE0110 (H), BMXNOC0401, BMXNOR0200H RTU (All Versions), Modicon Premium Processors with integrated Ethernet (Copro): TSXP574634, TSXP575634, TSXP576634 (All Versions), Modicon Quantum Processors with Integrated Ethernet (Copro): 140CPU65xxxxx (All Versions), Modicon Quantum Communication Modules: 140NOE771x1, 140NOC78x00, 140NOC77101 (All Versions), Modicon Premium Communication Modules: TSXETY4103, TSXETY5103 (All Versions) | ||||
| CVE-2021-22785 | 1 Schneider-electric | 28 140cpu65150, 140cpu65150 Firmware, 140noc77101 and 25 more | 2026-05-29 | 7.5 High |
| A CWE-200: Information Exposure vulnerability exists that could cause sensitive information of files located in the web root directory to leak when an attacker sends a HTTP request to the web server of the device. Affected Product: Modicon M340 CPUs: BMXP34 (Versions prior to V3.40), Modicon M340 X80 Ethernet Communication Modules: BMXNOE0100 (H), BMXNOE0110 (H), BMXNOC0401, BMXNOR0200H RTU (All Versions), Modicon Premium Processors with integrated Ethernet (Copro): TSXP574634, TSXP575634, TSXP576634 (All Versions), Modicon Quantum Processors with Integrated Ethernet (Copro): 140CPU65xxxxx (All Versions), Modicon Quantum Communication Modules: 140NOE771x1, 140NOC78x00, 140NOC77101 (All Versions), Modicon Premium Communication Modules: TSXETY4103, TSXETY5103 (All Versions) | ||||
| CVE-2021-22713 | 1 Schneider-electric | 21 Ion7650 Firmware, Powerlogic Ion7300, Powerlogic Ion7300 Firmware and 18 more | 2026-05-29 | 7.5 High |
| A CWE-119:Improper restriction of operations within the bounds of a memory buffer vulnerability exists in PowerLogic ION8650, ION8800, ION7650, ION7700/73xx, and ION83xx/84xx/85xx/8600 (see security notifcation for affected versions), which could cause the meter to reboot. | ||||
| CVE-2018-7795 | 1 Schneider-electric | 2 Powerlogic Pm5560, Powerlogic Pm5560 Firmware | 2026-05-29 | 5.4 Medium |
| A Cross Protocol Injection vulnerability exists in Schneider Electric's PowerLogic (PM5560 prior to FW version 2.5.4) product. The vulnerability makes the product susceptible to cross site scripting attack on its web browser. User inputs can be manipulated to cause execution of java script code. | ||||
| CVE-2020-7567 | 1 Schneider-electric | 2 Modicon M221, Modicon M221 Firmware | 2026-05-29 | 7.1 High |
| A CWE-311: Missing Encryption of Sensitive Data vulnerability exists in Modicon M221 (all references, all versions) that could allow the attacker to find the password hash when the attacker has captured the traffic between EcoStruxure Machine - Basic software and Modicon M221 controller and broke the encryption keys. | ||||