CVE-2025-66177 1 Hikvision 99 Ds-2cd1xx1, Ds-2cd1xxxg0(t), Ds-2cd1xxxg2 and 96 more 2026-07-09 8.8 High
There is a Buffer overflow Vulnerability in the device Search and Discovery feature of Hikvision NVR/DVR/CVR/IPC models. If exploited, an attacker on the same local area network (LAN) could cause the device to malfunction by sending specially crafted packets to an unpatched device.
CVE-2025-66176 1 Hikvision 65 Ds-k1t105a, Ds-k1t105a Firmware, Ds-k1t201a and 62 more 2026-07-09 8.8 High
There is a Buffer overflow Vulnerability in the device Search and Discovery feature of Hikvision Access Control Products. If exploited, an attacker on the same local area network (LAN) could cause the device to malfunction by sending specially crafted packets to an unpatched device.
CVE-2026-56809 1 Ricoh 1 Multiple Laser Printers And Mfps Which Implement Web Image Monitor 2026-07-09 N/A
Multiple laser printers and MFPs (multifunction printers) which implement Ricoh Web Image Monitor contain a reflected cross-site scripting vulnerability. An arbitrary script may be executed on the web browser of the user who accesses a crafted URL.
CVE-2026-14383 1 Google 1 Chrome 2026-07-09 8.8 High
Inappropriate implementation in V8 in Google Chrome prior to 150.0.7871.46 allowed a remote attacker to execute arbitrary code inside a sandbox via a crafted HTML page. (Chromium security severity: Medium)
CVE-2026-14401 1 Google 1 Chrome 2026-07-09 8.3 High
Insufficient validation of untrusted input in ANGLE in Google Chrome on Android prior to 150.0.7871.46 allowed a remote attacker who had compromised the renderer process to potentially perform a sandbox escape via a crafted HTML page. (Chromium security severity: High)
CVE-2026-14413 1 Google 1 Chrome 2026-07-09 8.3 High
Uninitialized Use in ANGLE in Google Chrome prior to 150.0.7871.46 allowed a remote attacker who had compromised the renderer process to potentially perform a sandbox escape via a crafted HTML page. (Chromium security severity: High)
CVE-2026-14390 1 Google 1 Chrome 2026-07-09 9.6 Critical
Use after free in ANGLE in Google Chrome prior to 150.0.7871.46 allowed a remote attacker to potentially perform a sandbox escape via a crafted HTML page. (Chromium security severity: High)
CVE-2026-52187 1 Utt 1 Nv518g 2026-07-09 7.5 High
Buffer Overflow vulnerability in UTT nv518G nv518GV3v3.2.7-210919-161313 allows a remote attacker to cause a denial of service via the gohead/sub_483ba0 component
CVE-2026-52192 1 Utt 1 Nv518g 2026-07-09 7.5 High
An issue in UTT nv518G nv518GV3v3.2.7-210919-161313 allows a remote attacker to cause a denial of service via the gohead/sub_445C5C component
CVE-2026-38970 2026-07-09 7.5 High
pdfcpu through v0.11.1 contains an uncontrolled-recursion denial-of-service issue in pkg/pdfcpu/model/parse.go. The parser descends recursively through nested PDF objects, including arrays, via ParseObjectContext() and parseArray() without enforcing a maximum nesting depth.
CVE-2026-38971 1 Ardupilot 1 Ardupilot 2026-07-09 9.1 Critical
ardupilot through Plane-4.6.3 was found to contain an out-of-bounds read issue in libraries/GCS_MAVLink/GCS_serial_control.cpp in GCS_MAVLINK::handle_serial_control().
CVE-2026-54405 1 Ubiquiti 1 Unifi Network Application 2026-07-09 7.5 High
A malicious actor with access to the network could exploit an Improper Input Validation vulnerability found in UniFi Network Application to execute a Denial of Service (DoS) attack on the application.
CVE-2026-54403 2026-07-09 8.6 High
A malicious actor with access to the network could exploit a Path Traversal vulnerability found in certain devices running UniFi OS to bypass authentication of such UniFi OS devices or instances.
CVE-2026-55119 2026-07-09 8.1 High
A malicious actor with access to the network and low privileges could exploit an Improper Access Control vulnerability found in UniFi Talk Application to escalate privileges within the UniFi Talk Application.
CVE-2026-10055 1 Eclipse 1 Theia 2026-07-09 8.5 High
In Eclipse Theia since version 1.26.0, the backend /services/request-service RPC accepts an attacker-controlled URL from any client connected to the standard /services messaging endpoint, performs the HTTP request server-side, and returns the full response body to the caller. Because the destination URL is neither validated nor allowlisted, a remote attacker with access to the Theia service connection can issue server-side HTTP requests to localhost or other backend-reachable hosts and read their responses, exposing internal administrative endpoints, cloud instance metadata services, and other resources that are intentionally outside the browser network boundary. The vulnerability affects deployments where the Theia service connection is reachable by untrusted users (for example, multi-tenant or publicly-reachable Theia deployments).
CVE-2026-41124 1 Dell 1 Powerprotect Data Domain 2026-07-09 2.3 Low
Dell PowerProtect Data Domain, versions 7.7.1.0 through 8.6, LTS2026 release version 8.6.1.0 through 8.6.1.10, LTS2025 release version 8.3.1.0 through 8.3.1.30, LTS2024 release versions 7.13.1.0 through 7.13.1.70 contain an Improper limitation of a pathname to a restricted directory ('path traversal') vulnerability. A high privileged attacker with local access could potentially exploit this vulnerability, leading to Information exposure.
CVE-2026-46468 1 Dell 1 Powerprotect Data Domain 2026-07-09 4.4 Medium
Dell PowerProtect Data Domain, versions 7.7.1.0 through 8.7, LTS2026 release version 8.6.1.0 through 8.6.1.10, LTS2025 release version 8.3.1.0 through 8.3.1.30, LTS2024 release versions 7.13.1.0 through 7.13.1.70 contain an improper link resolution before file access ('Link following') vulnerability. A high privileged attacker with local access could potentially exploit this vulnerability, leading to information exposure.
CVE-2026-53478 1 Dell 1 Powerprotect Data Domain 2026-07-09 7.2 High
Dell PowerProtect Data Domain, versions 7.7.1.0 through 8.7, LTS2026 release version 8.6.1.0 through 8.6.1.10, LTS2025 release version 8.3.1.0 through 8.3.1.30, LTS2024 release versions 7.13.1.0 through 7.13.1.70 contain an improper neutralization of special elements used in an OS command ('OS command Injection') vulnerability. A high privileged attacker with remote access could potentially exploit this vulnerability, leading to command execution.
CVE-2026-49814 1 Dell 1 Powerprotect Data Domain 2026-07-09 7.2 High
Dell PowerProtect Data Domain, versions 7.7.1.0 through 8.7, LTS2026 release version 8.6.1.0 through 8.6.1.10, LTS2025 release version 8.3.1.0 through 8.3.1.30, LTS2024 release versions 7.13.1.0 through 7.13.1.70 contain an Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability. A high privileged attacker with remote access could potentially exploit this vulnerability, leading to arbitrary command execution.
CVE-2026-38973 2026-07-09 4.4 Medium
mrubyc through release3.4.1 was found to contain an out-of-bounds read in builtin missing-method lookup inside mrbc_find_method().