Export limit exceeded: 18300 CVEs match your query. Please refine your search to export 10,000 CVEs or fewer.
Search
Search Results (18300 CVEs found)
| CVE | Vendors | Products | Updated | CVSS v3.1 |
|---|---|---|---|---|
| CVE-2024-31967 | 1 Mitel | 3 6800 Series Sip Phones, 6900 Series Sip Phones, 6970 Conference Unit | 2026-04-15 | 9.1 Critical |
| A vulnerability on Mitel 6800 Series and 6900 Series SIP Phones through 6.3 SP3 HF4, 6900w Series SIP Phone through 6.3.3, and 6970 Conference Unit through 5.1.1 SP8 allows an unauthenticated attacker to conduct an unauthorized access attack due to improper access control. A successful exploit could allow an attacker to gain unauthorized access to user information or the system configuration. | ||||
| CVE-2024-45036 | 2026-04-15 | N/A | ||
| Tophat is a mobile applications testing harness. An Improper Access Control vulnerability can expose the `TOPHAT_APP_TOKEN` token stored in `~/.tophatrc` through use of a malicious Tophat URL controlled by the attacker. The vulnerability allows Tophat to send this token to the attacker's server without any checks to ensure that the server is trusted. This token can then be used to access internal build artifacts, for mobile applications, not intended to be public. The issue has been patched as of version 1.10.0. The ability to request artifacts using a Tophat API has been deprecated as this flow was inherently insecure. Systems that have implemented this kind of endpoint should cease use and invalidate the token immediately. There are no workarounds and all users should update as soon as possible. | ||||
| CVE-2024-45208 | 1 Versa | 1 Director | 2026-04-15 | 9.8 Critical |
| The Versa Director SD-WAN orchestration platform which makes use of Cisco NCS application service. Active and Standby Directors communicate over TCP ports 4566 and 4570 to exchange High Availability (HA) information using a shared password. Affected versions of Versa Director bound to these ports on all interfaces. An attacker that can access the Versa Director could access the NCS service on port 4566 and exploit it to perform unauthorized administrative actions and perform remote code execution. Customers are recommended to follow the hardening guide. Versa Networks is not aware of any reported instance where this vulnerability was exploited. Proof of concept for this vulnerability has been disclosed by third party security researchers. | ||||
| CVE-2024-12287 | 1 Wordpress | 1 Wordpress | 2026-04-15 | 9.8 Critical |
| The Biagiotti Membership plugin for WordPress is vulnerable to authentication bypass in all versions up to, and including, 1.0.2. This is due to the plugin not properly verifying a user's identity prior to authenticating them. This makes it possible for unauthenticated attackers to log in as other users, such as administrators, granted they have access to an email. | ||||
| CVE-2025-23164 | 2026-04-15 | N/A | ||
| A misconfigured access token mechanism in the Unifi Protect Application (Version 5.3.41 and earlier) could permit the recipient of a "Share Livestream" link to maintain access to the corresponding livestream subsequent to such link becoming disabled. | ||||
| CVE-2021-47155 | 1 Perl | 1 Perl | 2026-04-15 | 9.1 Critical |
| The Net::IPV4Addr module 0.10 for Perl does not properly consider extraneous zero characters in an IP address string, which (in some situations) allows attackers to bypass access control that is based on IP addresses. | ||||
| CVE-2025-0980 | 2 Linux, Nokia | 2 Linux, Service Router Linux | 2026-04-15 | 6.4 Medium |
| Nokia SR Linux is vulnerable to an authentication vulnerability allowing unauthorized access to the JSON-RPC service. When exploited, an invalid validation allows JSON RPC access without providing valid authentication credentials. | ||||
| CVE-2025-60772 | 1 Netlink | 1 Hg322g | 2026-04-15 | 9.8 Critical |
| Improper authentication in the web-based management interface of NETLINK HG322G V1.0.00-231017, allows a remote unauthenticated attacker to escalate privileges and lock out the legitimate administrator via crafted HTTP requests. | ||||
| CVE-2022-33862 | 1 Eaton | 1 Intelligent Power Protector | 2026-04-15 | 6.7 Medium |
| IPP software prior to v1.71 is vulnerable to default credential vulnerability. This could lead attackers to identify and access vulnerable systems. | ||||
| CVE-2024-47816 | 2026-04-15 | 6.4 Medium | ||
| ImportDump is a mediawiki extension designed to automate user import requests. A user's local actor ID is stored in the database to tell who made what requests. Therefore, if a user on another wiki happens to have the same actor ID as someone on the central wiki, the user on the other wiki can act as if they're the original wiki requester. This can be abused to create new comments, edit the request, and view the request if it's marked private. This issue has been addressed in commit `5c91dfc` and all users are advised to update. Users unable to update may disable the special page outside of their global wiki. See `miraheze/mw-config@e566499` for details on that. | ||||
| CVE-2024-29207 | 2026-04-15 | N/A | ||
| An Improper Certificate Validation could allow a malicious actor with access to an adjacent network to take control of the system. Affected Products: UniFi Connect Application (Version 3.7.9 and earlier) UniFi Connect EV Station (Version 1.1.18 and earlier) UniFi Connect EV Station Pro (Version 1.1.18 and earlier) UniFi Connect Display (Version 1.9.324 and earlier) UniFi Connect Display Cast (Version 1.6.225 and earlier) Mitigation: Update UniFi Connect Application to Version 3.10.7 or later. Update UniFi Connect EV Station to Version 1.2.15 or later. Update UniFi Connect EV Station Pro to Version 1.2.15 or later. Update UniFi Connect Display to Version 1.11.348 or later. Update UniFi Connect Display Cast to Version 1.8.255 or later. | ||||
| CVE-2025-10947 | 2026-04-15 | 5.3 Medium | ||
| A flaw has been found in Sistemas Pleno Gestão de Locação up to 2025.7.x. The impacted element is an unknown function of the file /api/areacliente/pessoa/validarCpf of the component CPF Handler. Executing a manipulation of the argument pes_cpf can lead to authorization bypass. The attack can be executed remotely. The exploit has been published and may be used. Upgrading to version 2025.8.0 is sufficient to resolve this issue. It is advisable to upgrade the affected component. | ||||
| CVE-2022-45929 | 1 Northern.tech | 1 Mender | 2026-04-15 | 8.8 High |
| Northern.tech Mender 3.3.x before 3.3.2, 3.5.x before 3.5.0, and 3.6.x before 3.6.0 has Incorrect Access Control and allows users to change their roles and could allow privilege escalation from a low-privileged read-only user to a high-privileged user. | ||||
| CVE-2025-50434 | 2026-04-15 | 5.3 Medium | ||
| A security issue has been identified in Appian Enterprise Business Process Management version 25.3. The vulnerability is related to incorrect access control, which under certain conditions could allow unauthorized access to information. NOTE: this has been disputed because the CVE Record information does not originate from the Supplier, and the report lacks specificity about why a problem exists, how the behavior could be reproduced, and whether any action could be taken to resolve the problem. | ||||
| CVE-2024-26291 | 2026-04-15 | N/A | ||
| An Unauthenticated Arbitrary File Read vulnerability affects the Agent when installed on a system. The parameter filename does not validate the path thus allowing users to read arbitrary files. As the application runs with the highest privileges (root/NT_AUTHORITY SYSTEM) by default attackers are able to obtain sensitive information. This issue affects Avid NEXIS E-series: before 2025.5.1; Avid NEXIS F-series: before 2025.5.1; Avid NEXIS PRO+: before 2025.5.1; System Director Appliance (SDA+): before 2025.5.1. | ||||
| CVE-2024-53304 | 2026-04-15 | 6.5 Medium | ||
| An issue in LRQA Nettitude PoshC2 after commit 09ee2cf allows unauthenticated attackers to connect to the C2 server and execute arbitrary commands via posing as an infected machine. | ||||
| CVE-2025-27254 | 2026-04-15 | 8 High | ||
| CWE-282 "Improper Ownership Management" in GE Vernova EnerVista UR Setup allows Authentication Bypass. The software's startup authentication can be disabled by altering a Windows registry setting that any user can modify. | ||||
| CVE-2024-45347 | 2 Mi, Xiaomi | 2 Xiaomi, Mi Connect Service | 2026-04-15 | 9.6 Critical |
| An unauthorized access vulnerability exists in the Xiaomi Mi Connect Service APP. The vulnerability is caused by the validation logic is flawed and can be exploited by attackers to Unauthorized access to the victim’s device. | ||||
| CVE-2024-20397 | 2026-04-15 | 5.2 Medium | ||
| A vulnerability in the bootloader of Cisco NX-OS Software could allow an unauthenticated attacker with physical access to an affected device, or an authenticated, local attacker with administrative credentials, to bypass NX-OS image signature verification. This vulnerability is due to insecure bootloader settings. An attacker could exploit this vulnerability by executing a series of bootloader commands. A successful exploit could allow the attacker to bypass NX-OS image signature verification and load unverified software. | ||||
| CVE-2024-34519 | 2026-04-15 | 6.8 Medium | ||
| Avantra Server 24.x before 24.0.7 and 24.1.x before 24.1.1 mishandles the security of dashboards, aka XAN-5367. If a user can create a dashboard with an auto-login user, data disclosure may occur. Access control can be bypassed when there is a shared dashboard, and its auto-login user has privileges that a dashboard visitor should not have. | ||||