Export limit exceeded: 14161 CVEs match your query. Please refine your search to export 10,000 CVEs or fewer.
Search
Search Results (14161 CVEs found)
| CVE | Vendors | Products | Updated | CVSS v3.1 |
|---|---|---|---|---|
| CVE-2023-51958 | 1 Tenda | 2 Ax1803, Ax1803 Firmware | 2024-11-21 | 9.8 Critical |
| Tenda AX1803 v1.0.0.1 contains a stack overflow via the iptv.stb.port parameter in the function formGetIptv. | ||||
| CVE-2023-51957 | 1 Tenda | 2 Ax1803, Ax1803 Firmware | 2024-11-21 | 9.8 Critical |
| Tenda AX1803 v1.0.0.1 contains a stack overflow via the iptv.stb.mode parameter in the function formGetIptv. | ||||
| CVE-2023-51136 | 1 Totolink | 2 X2000r, X2000r Firmware | 2024-11-21 | 9.8 Critical |
| TOTOLINK X2000R Gh v1.0.0-B20230221.0948.web was discovered to contain a stack overflow via the function formRebootSchedule. | ||||
| CVE-2023-51135 | 1 Totolink | 2 X2000r, X2000r Firmware | 2024-11-21 | 9.8 Critical |
| TOTOLINK X2000R Gh v1.0.0-B20230221.0948.web was discovered to contain a stack overflow via the function formPasswordSetup. | ||||
| CVE-2023-51133 | 1 Totolink | 2 X2000r, X2000r Firmware | 2024-11-21 | 9.8 Critical |
| TOTOLINK X2000R Gh v1.0.0-B20230221.0948.web was discovered to contain a stack overflow via the function formRoute. | ||||
| CVE-2023-51102 | 1 Tenda | 2 W9, W9 Firmware | 2024-11-21 | 9.8 Critical |
| Tenda W9 V1.0.0.7(4456)_CN was discovered to contain a stack overflow via the function formWifiMacFilterSet. | ||||
| CVE-2023-51095 | 1 Tenda | 2 M3, M3 Firmware | 2024-11-21 | 9.8 Critical |
| Tenda M3 V1.0.0.12(4856) was discovered to contain a stack overflow via the function formDelWlRfPolicy. | ||||
| CVE-2023-51093 | 1 Tenda | 2 M3, M3 Firmware | 2024-11-21 | 9.8 Critical |
| Tenda M3 V1.0.0.12(4856) was discovered to contain a stack overflow via the function fromSetLocalVlanInfo. | ||||
| CVE-2023-51092 | 1 Tenda | 2 M3, M3 Firmware | 2024-11-21 | 9.8 Critical |
| Tenda M3 V1.0.0.12(4856) was discovered to contain a stack overflow via the function upgrade. | ||||
| CVE-2023-51091 | 1 Tenda | 2 M3, M3 Firmware | 2024-11-21 | 9.8 Critical |
| Tenda M3 V1.0.0.12(4856) was discovered to contain a stack overflow via the function R7WebsSecurityHandler. | ||||
| CVE-2023-51090 | 1 Tenda | 2 M3, M3 Firmware | 2024-11-21 | 9.8 Critical |
| Tenda M3 V1.0.0.12(4856) was discovered to contain a stack overflow via the function formGetWeiXinConfig. | ||||
| CVE-2023-50992 | 1 Tenda | 2 I29, I29 Firmware | 2024-11-21 | 9.8 Critical |
| Tenda i29 v1.0 V1.0.0.5 was discovered to contain a stack overflow via the ip parameter in the setPing function. | ||||
| CVE-2023-50990 | 1 Tenda | 2 I29, I29 Firmware | 2024-11-21 | 9.8 Critical |
| Tenda i29 v1.0 V1.0.0.5 was discovered to contain a buffer overflow via the rebootTime parameter in the sysScheduleRebootSet function. | ||||
| CVE-2023-50988 | 1 Tenda | 2 I29, I29 Firmware | 2024-11-21 | 9.8 Critical |
| Tenda i29 v1.0 V1.0.0.5 was discovered to contain a buffer overflow via the bandwidth parameter in the wifiRadioSetIndoor function. | ||||
| CVE-2023-50987 | 1 Tenda | 2 I29, I29 Firmware | 2024-11-21 | 9.8 Critical |
| Tenda i29 v1.0 V1.0.0.5 was discovered to contain a buffer overflow via the time parameter in the sysTimeInfoSet function. | ||||
| CVE-2023-50986 | 1 Tenda | 2 I29, I29 Firmware | 2024-11-21 | 8.8 High |
| Tenda i29 v1.0 V1.0.0.5 was discovered to contain a buffer overflow via the time parameter in the sysLogin function. | ||||
| CVE-2023-50985 | 1 Tenda | 2 I29, I29 Firmware | 2024-11-21 | 9.8 Critical |
| Tenda i29 v1.0 V1.0.0.5 was discovered to contain a buffer overflow via the lanGw parameter in the lanCfgSet function. | ||||
| CVE-2023-50984 | 1 Tenda | 2 I29, I29 Firmware | 2024-11-21 | 9.8 Critical |
| Tenda i29 v1.0 V1.0.0.5 was discovered to contain a buffer overflow via the ip parameter in the spdtstConfigAndStart function. | ||||
| CVE-2023-50965 | 1 Starnight | 1 Micro Http Server | 2024-11-21 | 9.8 Critical |
| In MicroHttpServer (aka Micro HTTP Server) through 4398570, _ReadStaticFiles in lib/middleware.c allows a stack-based buffer overflow and potentially remote code execution via a long URI. | ||||
| CVE-2023-50002 | 1 Tenda | 2 W30e, W30e Firmware | 2024-11-21 | 9.8 Critical |
| Tenda W30E V16.01.0.12(4843) was discovered to contain a stack overflow via the function formRebootMeshNode. | ||||