Export limit exceeded: 16673 CVEs match your query. Please refine your search to export 10,000 CVEs or fewer.

Search

Search Results (16673 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2024-47295 1 Seiko Epson Corporation 1 Web Config 2026-04-15 8.1 High
Insecure initial password configuration issue in SEIKO EPSON Web Config allows a remote unauthenticated attacker to set an arbitrary password and operate the device with an administrative privilege. As for the details of the affected versions, see the information provided by the vendor under [References].
CVE-2025-6752 1 Linksys 4 Ea7200, Ea7450, Ea7500 and 1 more 2026-04-15 8.8 High
A vulnerability has been found in Linksys WRT1900ACS, EA7200, EA7450 and EA7500 up to 20250619 and classified as critical. This vulnerability affects the function SetDefaultConnectionService of the file /upnp/control/Layer3Forwarding of the component IGD. The manipulation of the argument NewDefaultConnectionService leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2025-2441 2026-04-15 4.6 Medium
CWE-1188: Initialization of a Resource with an Insecure Default vulnerability exists that could lead to loss of confidentiality when a malicious user, having physical access, sets the radio in factory default mode where the product does not correctly initialize all data.
CVE-2025-41713 1 Wago 1 Cc100 2026-04-15 6.5 Medium
During a short time frame while the device is booting an unauthenticated remote attacker can send traffic to unauthorized networks due to the switch operating in an undefined state until a CPU-induced reset allows proper configuration.
CVE-2025-59044 1 Himmelblau-idm 1 Himmelblau 2026-04-15 4.4 Medium
Himmelblau is an interoperability suite for Microsoft Azure Entra ID and Intune. Himmelblau 0.9.x derives numeric GIDs for Entra ID groups from the group display name when himmelblau.conf `id_attr_map = name` (the default configuration). Because Microsoft Entra ID allows multiple groups with the same `displayName` (including end-user–created personal/O365 groups, depending on tenant policy), distinct directory groups can collapse to the same numeric GID on Linux. This issue only applies to Himmelblau versions 0.9.0 through 0.9.22. Any resource or service on a Himmelblau-joined host that enforces authorization by numeric GID (files/dirs, etc.) can be unintentionally accessible to a user who creates or joins a different Entra/O365 group that happens to share the same `displayName` as a privileged security group. Users should upgrade to 0.9.23, or 1.0.0 or later, to receive a patch. Group to GID mapping now uses Entra ID object IDs (GUIDs) and does not collide on same-name groups. As a workaround, use tenant policy hardening to restrict arbitrary group creation until all hosts are patched.
CVE-2023-32666 1 Intel 336 E3-1220l Firmware, E3-1226 Firmware, E3-1230l Firmware and 333 more 2026-04-15 7.2 High
On-chip debug and test interface with improper access control in some 4th Generation Intel(R) Xeon(R) Processors when using Intel(R) SGX or Intel(R) TDX may allow a privileged user to potentially enable escalation of privilege via local access.
CVE-2025-7353 1 Rockwellautomation 1 Controllogix 2026-04-15 N/A
A security issue exists due to the web-based debugger agent enabled on Rockwell Automation ControlLogix® Ethernet Modules. If a specific IP address is used to connect to the WDB agent, it can allow remote attackers to perform memory dumps, modify memory, and control execution flow.
CVE-2025-47271 2026-04-15 N/A
The OZI action is a GitHub Action that publishes releases to PyPI and mirror releases, signature bundles, and provenance in a tagged release. In versions 1.13.2 through 1.13.5, potentially untrusted data flows into PR creation logic. A malicious actor could construct a branch name that injects arbitrary code. This is patched in 1.13.6. As a workaround, one may downgrade to a version prior to 1.13.2.
CVE-2025-42896 1 Sap 1 Businessobjects Business Intelligence Platform 2026-04-15 5.4 Medium
SAP BusinessObjects Business Intelligence Platform lets an unauthenticated remote attacker send crafted requests through the URL parameter that controls the login page error message. This can cause the server to fetch attacker-supplied URLs, resulting in low impact to confidentiality and integrity, and no impact to availability.
CVE-2025-55729 1 Xwikisas 1 Xwiki-pro-macros 2026-04-15 10 Critical
XWiki Remote Macros provides XWiki rendering macros that are useful when migrating content from Confluence. Starting in version 1.0 and prior to version 1.26.5, missing escaping of the ac:type in the ConfluenceLayoutSection macro allows remote code execution for any user who can edit any page The classes parameter is used without escaping in XWiki syntax, thus allowing XWiki syntax injection which enables remote code execution. Version 1.26.5 has a fix for the issue.
CVE-2024-23194 1 Gallagher 1 Command Centre 2026-04-15 3.3 Low
Improper output Neutralization for Logs (CWE-117) in the Command Centre API Diagnostics Endpoint could allow an attacker limited ability to modify Command Centre log files. This issue affects: Gallagher Command Centre v9.10 prior to vEL9.10.1268 (MR1).
CVE-2025-9020 1 Dronecode 1 Px4 Drone Autopilot 2026-04-15 4.5 Medium
A vulnerability was found in PX4 PX4-Autopilot up to 1.15.4. This issue affects the function MavlinkReceiver::handle_message_serial_control of the file src/modules/mavlink/mavlink_receiver.cpp of the component Mavlink Shell Closing Handler. The manipulation of the argument _mavlink_shell leads to use after free. An attack has to be approached locally. The complexity of an attack is rather high. The exploitation is known to be difficult. The identifier of the patch is 4395d4f00c49b888f030f5b43e2a779f1fa78708. It is recommended to apply a patch to fix this issue.
CVE-2022-38696 2026-04-15 9.8 Critical
In BootRom, there's a possible missing payload size check. This could lead to memory buffer overflow without requiring additional execution privileges.
CVE-2025-59936 1 Nearform 1 Get-jwks 2026-04-15 N/A
get-jwks contains fetch utils for JWKS keys. In versions prior to 11.0.2, a vulnerability in get-jwks can lead to cache poisoning in the JWKS key-fetching mechanism. When the iss (issuer) claim is validated only after keys are retrieved from the cache, it is possible for cached keys from an unexpected issuer to be reused, resulting in a bypass of issuer validation. This design flaw enables a potential attack where a malicious actor crafts a pair of JWTs, the first one ensuring that a chosen public key is fetched and stored in the shared JWKS cache, and the second one leveraging that cached key to pass signature validation for a targeted iss value. The vulnerability will work only if the iss validation is done after the use of get-jwks for keys retrieval. This issue has been patched in version 11.0.2.
CVE-2025-3497 2026-04-15 8.7 High
The Linux distribution underlying the Radiflow iSAP Smart Collector (CentOS 7 - VSAP 1.20) is obsolete and reached end of life (EOL) on June 30, 2024. Thus, any unmitigated vulnerability could be exploited to affect this product.
CVE-2025-10392 1 Mercury 1 Km08-708h Giga Wifi Wave2 2026-04-15 9.8 Critical
A vulnerability was detected in Mercury KM08-708H GiGA WiFi Wave2 1.1.14. This affects an unknown function of the component HTTP Header Handler. The manipulation of the argument Host results in stack-based buffer overflow. The attack can be executed remotely. The exploit is now public and may be used.
CVE-2025-59097 1 Dormakaba 1 Access Manager 2026-04-15 N/A
The exos 9300 application can be used to configure Access Managers (e.g. 92xx, 9230 and 9290). The configuration is done in a graphical user interface on the dormakaba exos server. As soon as the save button is clicked in exos 9300, the whole configuration is sent to the selected Access Manager via SOAP. The SOAP request is sent without any prior authentication or authorization by default. Though authentication and authorization can be configured using IPsec for 92xx-K5 devices and mTLS for 92xx-K7 devices, it is not enabled by default and must therefore be activated with additional steps. This insecure default allows an attacker with network level access to completely control the whole environment. An attacker is for example easily able to conduct the following tasks without prior authentication: - Re-configure Access Managers (e.g. remove alarming system requirements) - Freely re-configure the inputs and outputs - Open all connected doors permanently - Open all doors for a defined time interval - Change the admin password - and many more Network level access can be gained due to an insufficient network segmentation as well as missing LAN firewalls. Devices with an insecure configuration have been identified to be directly exposed to the internet.
CVE-2024-10498 1 Schneider-electric 1 Powerlogic Hdpm6000 2026-04-15 6.5 Medium
CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists that could allow an unauthorized attacker to modify configuration values outside of the normal range when the attacker sends specific Modbus write packets to the device which could result in invalid data or loss of web interface functionality.
CVE-2025-32078 2026-04-15 N/A
Improper Encoding or Escaping of Output vulnerability in The Wikimedia Foundation Mediawiki - Version Compare Extension allows Cross-Site Scripting (XSS).This issue affects Mediawiki - Version Compare Extension: from 1.39 through 1.43.
CVE-2025-1960 2026-04-15 9.8 Critical
CWE-1188: Initialization of a Resource with an Insecure Default vulnerability exists that could cause an attacker to execute unauthorized commands when a system’s default password credentials have not been changed on first use. The default username is not displayed correctly in the WebHMI interface.