Search
Search Results (6 CVEs found)
| CVE | Vendors | Products | Updated | CVSS v3.1 |
|---|---|---|---|---|
| CVE-2026-11499 | 1 Tenda | 2 Hg10, Hg7hg9 | 2026-06-08 | 9.8 Critical |
| A vulnerability was determined in Tenda HG7HG9 and HG10 300001138_en_xpon. This affects the function formDOMAINBLK of the file /boaform/formDOMAINBLK. Executing a manipulation of the argument blkDomain can lead to stack-based buffer overflow. The attack may be performed from remote. | ||||
| CVE-2026-11498 | 1 Tenda | 2 Hg10, Hg7hg9 | 2026-06-08 | 8.8 High |
| A vulnerability was found in Tenda HG7HG9 and HG10 300001138_en_xpon. Affected by this issue is the function asp_voip_OtherSet of the file /boaform/voip_other_set of the component Web Management Interface. Performing a manipulation of the argument funckey_transfer results in stack-based buffer overflow. The attack is possible to be carried out remotely. | ||||
| CVE-2026-6988 | 1 Tenda | 2 Hg10, Hg10 Firmware | 2026-04-30 | 8.8 High |
| A flaw has been found in Tenda HG10 HG7_HG9_HG10re_300001138_en_xpon. This issue affects the function formRoute of the file /boaform/formRouting of the component Boa Service. This manipulation of the argument nextHop causes buffer overflow. It is possible to initiate the attack remotely. The exploit has been published and may be used. | ||||
| CVE-2026-1687 | 1 Tenda | 2 Hg10, Hg10 Firmware | 2026-04-18 | 7.3 High |
| A weakness has been identified in Tenda HG10 US_HG7_HG9_HG10re_300001138_en_xpon. Impacted is an unknown function of the file /boaform/formSamba of the component Boa Webserver. Executing a manipulation of the argument serverString can lead to command injection. It is possible to launch the attack remotely. The exploit has been made available to the public and could be used for attacks. | ||||
| CVE-2026-1689 | 1 Tenda | 2 Hg10, Hg10 Firmware | 2026-04-18 | 7.3 High |
| A vulnerability was detected in Tenda HG10 US_HG7_HG9_HG10re_300001138_en_xpon. The impacted element is the function checkUserFromLanOrWan of the file /boaform/admin/formLogin of the component Login Interface. The manipulation of the argument Host results in command injection. The attack can be launched remotely. The exploit is now public and may be used. | ||||
| CVE-2026-1690 | 1 Tenda | 2 Hg10, Hg10 Firmware | 2026-04-18 | 4.7 Medium |
| A flaw has been found in Tenda HG10 US_HG7_HG9_HG10re_300001138_en_xpon. This affects the function system of the file /boaform/formSysCmd. This manipulation of the argument sysCmd causes command injection. The attack may be initiated remotely. The exploit has been published and may be used. | ||||
Page 1 of 1.