Search Results (383 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2025-24331 2026-04-15 6.4 Medium
The Single RAN baseband OAM service is intended to run as an unprivileged service. However, it initially starts with root privileges and assigns certain capabilities before dropping to an unprivileged level. The capabilities retained from the root period are considered extensive after the privilege drop and, in theory, could potentially allow actions beyond the intended scope of the OAM service. These actions could include gaining root privileges, accessing root-owned files, modifying them as the file owner, and then returning them to root ownership. This issue has been corrected starting from release 24R1-SR 0.2 MP and later. Beginning with release 24R1-SR 0.2 MP, the OAM service software capabilities are restricted to the minimum necessary.
CVE-2025-32445 1 Argoproj 1 Argo Events 2026-04-15 10 Critical
Argo Events is an event-driven workflow automation framework for Kubernetes. A user with permission to create/modify EventSource and Sensor custom resources can gain privileged access to the host system and cluster, even without having direct administrative privileges. The EventSource and Sensor CRs allow the corresponding orchestrated pod to be customized with spec.template and spec.template.container (with type k8s.io/api/core/v1.Container), thus, any specification under container such as command, args, securityContext , volumeMount can be specified, and applied to the EventSource or Sensor pod. With these, a user would be able to gain privileged access to the cluster host, if he/she specified the EventSource/Sensor CR with some particular properties under template. This vulnerability is fixed in v1.9.6.
CVE-2024-35783 1 Siemens 6 Simatic Batch, Simatic Information Server, Simatic Pcs7 and 3 more 2026-04-15 9.1 Critical
A vulnerability has been identified in SIMATIC BATCH V9.1 (All versions), SIMATIC Information Server 2020 (All versions < V2020 SP2 Update 5), SIMATIC Information Server 2022 (All versions < V2022 SP1 Update 2), SIMATIC PCS 7 V9.1 (All versions < V9.1 SP2 UC06), SIMATIC Process Historian 2020 (All versions < V2020 SP2 Update 5), SIMATIC Process Historian 2022 (All versions < V2022 SP1 Update 2), SIMATIC WinCC Runtime Professional V18 (All versions < V18 Update 5), SIMATIC WinCC Runtime Professional V19 (All versions < V19 Update 3), SIMATIC WinCC V7.4 (All versions), SIMATIC WinCC V7.5 (All versions < V7.5 SP2 Update 18), SIMATIC WinCC V8.0 (All versions < V8.0 Update 5). The affected products run their DB server with elevated privileges which could allow an authenticated attacker to execute arbitrary OS commands with administrative privileges.
CVE-2025-32802 1 Redhat 1 Enterprise Linux 2026-04-15 6.1 Medium
Kea configuration and API directives can be used to overwrite arbitrary files, subject to permissions granted to Kea. Many common configurations run Kea as root, leave the API entry points unsecured by default, and/or place the control sockets in insecure paths. This issue affects Kea versions 2.4.0 through 2.4.1, 2.6.0 through 2.6.2, and 2.7.0 through 2.7.8.
CVE-2024-43651 2026-04-15 N/A
Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability allows OS Command Injection as root This issue affects Iocharger firmware for AC models before version 241207101 Likelihood: Moderate – The <redacted> binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a crafted HTTP request. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services. CVSS clarification: Any network connection serving the web interface is vulnerable (AV:N) and there are no additional measures to circumvent (AC:L) nor does the attack require special conditions to be present (AT:N). The attack requires authentication, but the level does not matter (PR:L), nor is user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H) and a compromised device can be used to potentially "pivot" into a network that should nopt be reachable (SC:L/SI:L/SA:H). Because this is an EV charger handing significant power, there is a potential safety impact (S:P). THe attack can be autometed (AU:Y).
CVE-2024-43652 2026-04-15 8.8 High
Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability allows OS Command Injection as root This issue affects Iocharger firmware for AC model chargers before version 24120701 Likelihood: Moderate – The <redacted> binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a crafted HTTP request. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services.
CVE-2025-3364 1 Hgiga 1 Powerstation 2026-04-15 6.7 Medium
The SSH service of PowerStation from HGiga has a Chroot Escape vulnerability, allowing attackers with root privileges to bypass chroot restrictions and access the entire file system.
CVE-2024-43655 2026-04-15 N/A
Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability allows OS Command Injection as root This issue affects Iocharger firmware for AC model chargers before version 24120701. Likelihood: Moderate – The attacker will first need to find the name of the script, and needs a (low privilege) account to gain access to the script, or convince a user with such access to execute a request to it. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and deletefiles and services. CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y).
CVE-2025-22366 2026-04-15 N/A
The authenticated firmware update capability of the firmware for Mennekes Smart / Premium Chargingpoints can be abused for command execution because OS command are improperly neutralized when certain fields are passed to the underlying OS.
CVE-2024-28140 2026-04-15 6.1 Medium
The scanner device boots into a kiosk mode by default and opens the Scan2Net interface in a browser window. This browser is run with the permissions of the root user. There are also several other applications running as root user. This can be confirmed by running "ps aux" as the root user and observing the output.
CVE-2025-8907 2026-04-15 7 High
A vulnerability was found in H3C M2 NAS V100R006. Affected by this vulnerability is an unknown functionality of the component Webserver Configuration. The manipulation leads to execution with unnecessary privileges. An attack has to be approached locally. The complexity of an attack is rather high. The exploitation appears to be difficult. The exploit has been disclosed to the public and may be used. The vendor explains: "[T]he device only has configuration files and does not actually have boa functionality. It is impossible to access or upload files anonymously to the device through boa services". This vulnerability only affects products that are no longer supported by the maintainer.
CVE-2024-27143 1 Toshibatec 50 E-studio-2010-ac, E-studio-2015-nc, E-studio-2018 A and 47 more 2026-04-15 9.8 Critical
Toshiba printers use SNMP for configuration. Using the private community, it is possible to remotely execute commands as root on the remote printer. Using this vulnerability will allow any attacker to get a root access on a remote Toshiba printer. This vulnerability can be executed in combination with other vulnerabilities and difficult to execute alone. So, the CVSS score for this vulnerability alone is lower than the score listed in the "Base Score" of this vulnerability. For detail on related other vulnerabilities, please ask to the below contact point. https://www.toshibatec.com/contacts/products/ As for the affected products/models/versions, see the reference URL.
CVE-2025-6894 1 Moxa 7 Edf-g1002-bp, Edr-8010, Edr-g9010 and 4 more 2026-04-15 N/A
An Execution with Unnecessary Privileges vulnerability has been identified in Moxa’s network security appliances and routers. A flaw in the API authorization logic of the affected device allows an authenticated, low-privileged user to execute the administrative `ping` function, which is restricted to higher-privileged roles. This vulnerability enables the user to perform internal network reconnaissance, potentially discovering internal hosts or services that would otherwise be inaccessible. Repeated exploitation could lead to minor resource consumption. While the overall impact is limited, it may result in some loss of confidentiality and availability on the affected device. There is no impact on the integrity of the device, and the vulnerability does not affect any subsequent systems.
CVE-2024-28139 2026-04-15 8.8 High
The www-data user can elevate its privileges because sudo is configured to allow the execution of the mount command as root without a password. Therefore, the privileges can be escalated to the root user. The risk has been accepted by the vendor and won't be fixed in the near future.
CVE-2025-34290 2 Microsoft, Versa-networks 2 Windows, Sase Client 2026-04-15 N/A
Versa SASE Client for Windows versions released between 7.8.7 and 7.9.4 contain a local privilege escalation vulnerability in the audit log export functionality. The client communicates user-controlled file paths to a privileged service, which performs file system operations without impersonating the requesting user. Due to improper privilege handling and a time-of-check time-of-use race condition combined with symbolic link and mount point manipulation, a local authenticated attacker can coerce the service into deleting arbitrary directories with SYSTEM privileges. This can be exploited to delete protected system folders such as C:\\Config.msi and subsequently achieve execution as NT AUTHORITY\\SYSTEM via MSI rollback techniques.
CVE-2025-42943 1 Sap 1 Sap Gui 2026-04-15 4.5 Medium
SAP GUI for Windows may allow the leak of NTML hashes when specific ABAP frontend services are called with UNC paths. For a successful attack, the attacker needs developer authorization in a specific Application Server ABAP to make changes in the code, and the victim needs to execute by using SAP GUI for Windows. This could trigger automatic NTLM authentication, potentially exposing hashed credentials to an attacker. As a result, it has a high impact on the confidentiality.
CVE-2025-23395 2026-04-15 7.8 High
Screen 5.0.0 when it runs with setuid-root privileges does not drop privileges while operating on a user supplied path. This allows unprivileged users to create files in arbitrary locations with `root` ownership, the invoking user's (real) group ownership and file mode 0644. All data written to the Screen PTY will be logged into this file, allowing to escalate to root privileges
CVE-2025-50753 1 Mitrastar 1 Gpt-2741gnac-n2 2026-04-15 8.4 High
Mitrastar GPT-2741GNAC-N2 devices are provided with access through ssh into a restricted default shell.The command "deviceinfo show file" is supposed to be used from restricted shell to show files and directories. By providing " /bin/sh" (quotes included) to the argument of this command will drop a root shell.
CVE-2024-12673 1 Lenovo 1 Vantage 2026-04-15 7.8 High
An improper privilege vulnerability was reported in a BIOS customization feature of Lenovo Vantage on SMB notebook devices which could allow a local attacker to elevate privileges on the system. This vulnerability only affects Vantage installed on these devices: * Lenovo V Series (Gen 5) * ThinkBook 14 (Gen 6, 7) * ThinkBook 16 (Gen 6, 7) * ThinkPad E Series (Gen 1)
CVE-2024-27146 1 Toshibatec 50 E-studio-2010-ac, E-studio-2015-nc, E-studio-2018 A and 47 more 2026-04-15 6.7 Medium
The Toshiba printers do not implement privileges separation. As for the affected products/models/versions, see the reference URL.