Search

Search Results (382398 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2026-16991 1 Ibm 3 Aix, Powervm Vios, Vios 2026-08-24 7.8 High
IBM AIX 7.2, and 7.3 and IBM PowerVM VIOS 4.1 could allow a local attacker to gain elevated privileges due to improper handling of symbolic links.
CVE-2026-71915 1 Draytek 14 Vigorswitch Fx2120 Firmware, Vigorswitch G1282 Firmware, Vigorswitch G2100 Firmware and 11 more 2026-08-24 7.2 High
Multiple DrayTek VigorSwitch models contain a command injection vulnerability in the jsonstatus function. The vulnerability is caused by insufficient filtering of the usescript, usefile, and option fields before command execution. A remote attacker can trigger this vulnerability via crafted input to execute arbitrary commands with root privileges. Exploitation requires valid administrative credentials for the device's web management interface.
CVE-2026-71300 1 Apache 1 Camel 2026-08-24 N/A
Improper input validation vulnerability in Apache Camel Atmosphere Websocket component. This issue affects Apache Camel: from 4.0.0 before 4.14.9, from 4.15.0 before 4.18.4, from 4.19.0 before 4.22.0. The camel-atmosphere-websocket producer selects which connected WebSocket peers a message is delivered to through Exchange headers, and the string values of those headers sat outside the Camel namespace: websocket.connectionKey and websocket.connectionKey.list, along with websocket.sendToAll, websocket.eventType and websocket.errorType. WebsocketEndpoint extends ServletEndpoint and so inherits HttpHeaderFilterStrategy, which filters only the Camel and camel prefixes; the dotted names therefore fell outside the filtered namespace and were admitted in both directions by every HTTP-family consumer. In a route bridging an HTTP consumer into an atmosphere-websocket producer, an external sender could supply the list header and take over the producer's dispatch decision. WebsocketProducer.process tests the list header before the single-key header, so an injected value discarded the recipient the route had selected: a notification intended for one connected client could be suppressed, or delivered instead to a different client whose connection key the sender knows. The header need not be a query parameter and need not be supplied as a list literally - Camel's HTTP binding promotes a repeated header name, and a bracketed value, to a List when mapping onto the Exchange - so an ordinary inbound HTTP header is sufficient to reach the list-valued branch. This is distinct from CVE-2026-55993, which concerns the consumer-side query-parameter path in the same component. The behaviour dates back to the introduction of these constants, first released in 2.17.0, and was unchanged until this fix. Users are recommended to upgrade to version 4.22.0, which fixes the issue. If users are on the 4.14.x LTS releases stream, then they are suggested to upgrade to 4.14.9. If users are on the 4.18.x releases stream, then they are suggested to upgrade to 4.18.4. For deployments that cannot upgrade immediately, strip the dispatch headers at the trust boundary before the producer, for example with removeHeaders(“websocket.*”) placed between the HTTP consumer and the atmosphere-websocket producer. Note that the fix renames the header string values into the Camel namespace, which is a breaking change for routes that set them by literal string: routes referencing the WebsocketConstants fields symbolically are unaffected, and the change is documented in the upgrade guides. As defence in depth, do not bridge an untrusted HTTP consumer directly into a WebSocket producer whose dispatch is header-driven without stripping the dispatch namespace first.
CVE-2026-18102 1 Ibm 1 I 2026-08-24 3.5 Low
IBM i 7.6, 7.5, 7.4, and 7.3 could allow a remote authenticated attacker to overwrite adjacent memory due to an integer underflow during bounds checking.
CVE-2025-36254 1 Ibm 6 Ds8900f, Ds8900f Firmware, Ds8a00 and 3 more 2026-08-24 7.4 High
IBM System Storage DS8A00 10.1.3.0 through 10.11.35.0 and IBM DS8900F 89.40.83.0 through 89.44.25.0 could allow an attacker to bypass security authentication due to improperly encoding of DSCLI command output to obtain sensitive information or cause a denial of service.
CVE-2026-78367 1 Redhat 3 Enterprise Linux, Hummingbird, Openshift 2026-08-24 7 High
A vulnerability was found in RPM's rpmbuild tarball processing. When processing a crafted source archive, the getTarSpec() function in tools/rpmbuild.cc passes an attacker-controlled tar archive member name to rpmExpand() as part of a %{basename:...} macro expression. A specially crafted .spec member name can therefore inject RPM macros, including Lua expressions, resulting in arbitrary code execution with the privileges of the user running rpmbuild. This can be exploited when a victim or automated build system processes an attacker-controlled source tarball using rpmbuild tarball mode (such as -ts, -ta, or -tb).
CVE-2025-36398 1 Ibm 6 Ds8900f, Ds8900f Firmware, Ds8a00 and 3 more 2026-08-24 5.4 Medium
IBM System Storage DS8A00 10.1.3.0 through 10.11.35.0 and IBM DS8900F 89.40.83.0 through 89.44.25.0 could allow an authenticated user to read or modify another user's command history due to an externally controlled filename.
CVE-2025-36255 1 Ibm 6 Ds8900f, Ds8900f Firmware, Ds8a00 and 3 more 2026-08-24 7.5 High
IBM System Storage DS8A00 10.1.3.0 through 10.11.35.0 and IBM DS8900F 89.40.83.0 through 89.44.25.0 could allow an authenticated user to create a user with privileged user roles due to improper privileged defined with unsafe actions.
CVE-2026-76603 1 Fabrikar.com 1 Fabrik Extension For Joomla 2026-08-24 N/A
Joomla Extension - fabrikar.com - Unauthenticated row disclosure via form.inlineedit in Fabrik < 4.7.2 - The inineedit form controller does not perform any access checks, disclosing items to unauthorized users.
CVE-2026-76599 1 Fabrikar.com 1 Fabrik Extension For Joomla 2026-08-24 N/A
Joomla Extension - fabrikar.com - Unauthenticated database table list and table-prefix disclosure in Fabrik < 4.7.2 - The ajax_tables method of the elements model allows listings of arbitrary database tables including columns.
CVE-2026-76571 1 Fabrikar.com 1 Fabrik Extension For Joomla 2026-08-24 N/A
Joomla Extension - fabrikar.com - Unauthenticated SQL injection in list filter condition parameter in Fabrik < 4.7.2 - The condition parameter passed to a list filter is concatenated verbatim into the WHERE clause built by getFilterQuery(). An unauthenticated attacker can supply arbitrary SQL through the filter condition, giving full read of the database.
CVE-2026-71942 1 Draytek 14 Vigorswitch Fx2120 Firmware, Vigorswitch G1282 Firmware, Vigorswitch G2100 Firmware and 11 more 2026-08-24 7.2 High
Multiple DrayTek VigorSwitch models contain a buffer overflow vulnerability in the mail_mailalert function. The vulnerability is caused by concatenating multiple smtpReceiver email addresses into a fixed-size buffer without checking the remaining buffer size. A remote attacker can trigger this vulnerability via crafted input, causing a denial of service or potentially executing arbitrary commands. Exploitation requires valid administrative credentials for the device's web management interface.
CVE-2026-71940 1 Draytek 14 Vigorswitch Fx2120 Firmware, Vigorswitch G1282 Firmware, Vigorswitch G2100 Firmware and 11 more 2026-08-24 7.2 High
Multiple DrayTek VigorSwitch models contain a buffer overflow vulnerability in the acl_general_setup Edit ACE function. The vulnerability is caused by copying the name field into a fixed-size buffer without length validation. A remote attacker can trigger this vulnerability via crafted input, causing a denial of service or potentially executing arbitrary commands. Exploitation requires valid administrative credentials for the device's web management interface.
CVE-2026-71937 1 Draytek 14 Vigorswitch Fx2120 Firmware, Vigorswitch G1282 Firmware, Vigorswitch G2100 Firmware and 11 more 2026-08-24 7.2 High
Multiple DrayTek VigorSwitch models contain a buffer overflow vulnerability in the poe_schedule_profile function. The vulnerability is caused by repeated concatenation of the start_date, start_time, duration_time, how_often, weekdays, monthly_date, and cycle_duration fields into small fixed-size buffers without proper length checks. A remote attacker can trigger this vulnerability via crafted input, causing a denial of service or potentially executing arbitrary commands. Exploitation requires valid administrative credentials for the device's web management interface.
CVE-2026-71935 1 Draytek 14 Vigorswitch Fx2120 Firmware, Vigorswitch G1282 Firmware, Vigorswitch G2100 Firmware and 11 more 2026-08-24 7.2 High
Multiple DrayTek VigorSwitch models contain a buffer overflow vulnerability in the webBackupAction function. The vulnerability is caused by repeated string concatenation of the pathN, valueN, key, and option fields into fixed-size stack buffers without total length checks. A remote attacker can trigger this vulnerability via crafted input, causing a denial of service or potentially executing arbitrary commands. Exploitation requires valid administrative credentials for the device's web management interface.
CVE-2026-71932 1 Draytek 14 Vigorswitch Fx2120 Firmware, Vigorswitch G1282 Firmware, Vigorswitch G2100 Firmware and 11 more 2026-08-24 4.9 Medium
Multiple DrayTek VigorSwitch models contain a directory traversal vulnerability in the getSyslogFile function. The vulnerability is caused by insufficient validation of the option field. A remote attacker can trigger this vulnerability via crafted input containing path traversal sequences to access arbitrary files on the device. Exploitation requires valid administrative credentials for the device's web management interface.
CVE-2026-71927 1 Draytek 14 Vigorswitch Fx2120 Firmware, Vigorswitch G1282 Firmware, Vigorswitch G2100 Firmware and 11 more 2026-08-24 7.2 High
Multiple DrayTek VigorSwitch models contain a command injection vulnerability in the rebDevice function. The vulnerability is caused by insufficient filtering of the username and password fields before command execution. A remote attacker can trigger this vulnerability via crafted input to execute arbitrary commands with root privileges. Exploitation requires valid administrative credentials for the device's web management interface.
CVE-2026-71925 1 Draytek 14 Vigorswitch Fx2120 Firmware, Vigorswitch G1282 Firmware, Vigorswitch G2100 Firmware and 11 more 2026-08-24 7.2 High
Multiple DrayTek VigorSwitch models contain a command injection vulnerability in the getDetail function. The vulnerability is caused by insufficient filtering of the username and password fields before command execution. A remote attacker can trigger this vulnerability via crafted input to execute arbitrary commands with root privileges. Exploitation requires valid administrative credentials for the device's web management interface.
CVE-2026-71922 1 Draytek 14 Vigorswitch Fx2120 Firmware, Vigorswitch G1282 Firmware, Vigorswitch G2100 Firmware and 11 more 2026-08-24 7.5 High
Multiple DrayTek VigorSwitch models contain a pre-authentication null pointer dereference vulnerability in the setget.cgi interface. The vulnerability is caused by missing validation when the pass field is absent. A remote attacker can trigger this vulnerability via a crafted request to crash the service and cause a denial of service.
CVE-2026-71920 1 Draytek 14 Vigorswitch Fx2120 Firmware, Vigorswitch G1282 Firmware, Vigorswitch G2100 Firmware and 11 more 2026-08-24 4.9 Medium
Multiple DrayTek VigorSwitch models contain a null pointer dereference vulnerability in the formlogout function. The vulnerability is caused by missing checks for an empty or absent Cookie header before string handling. A remote attacker can trigger this vulnerability via a crafted request to crash the service and cause a denial of service. Exploitation requires valid administrative credentials for the device's web management interface.