| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| An unauthenticated remote attacker can run arbitrary commands on the affected devices with high privileges because the authentication for the Node_RED server is not configured by default. |
| Delta Electronics DIAView has an authentication bypass vulnerability. |
| A code execution security issue exists in the affected product. An attacker with physical access could abuse the maintenance menu of the controller with a crafted payload. The security issue can result in arbitrary code execution. |
| Incorrect access control in the component l_0_0.xml of TP-Link ARCHER-C7 v5 allows attackers to access sensitive information. |
| Missing Authentication for Critical Function vulnerability in ABB ALS-mini-s4 IP, ABB ALS-mini-s8 IP.This issue affects .
All firmware versions with the Serial Number from 2000 to 5166 |
| The health module has insufficient restrictions on loading URLs, which may lead to some information leakage. |
| Missing Authentication for Critical Function vulnerability in icegram Icegram allows Accessing Functionality Not Properly Constrained by ACLs.This issue affects Icegram: from n/a through 3.1.24. |
| Beward N100 M2.1.6.04C014 contains an unauthenticated vulnerability that allows remote attackers to access live video streams without credentials. Attackers can directly retrieve the camera's RTSP stream by exploiting the lack of authentication in the video access mechanism. |
| General Industrial Controls Lynx+ Gateway is missing critical authentication in the embedded web server which
could allow an attacker to send GET requests to obtain sensitive device
information. |
| Locally installed application can bypass the permission check and perform system operations that require permission. |
| An authentication bypass vulnerability has been identified in the REST and SOAP API components of Tripwire Enterprise (TE) 9.1.0 when TE is configured to use LDAP/Active Directory SAML authentication and its optional "Auto-synchronize LDAP Users, Roles, and Groups" feature is enabled. This vulnerability allows unauthenticated attackers to bypass authentication if a valid username is known. Exploitation of this vulnerability could allow remote attackers to gain privileged access to the APIs and lead to unauthorized information disclosure or modification. |
| Certain modes of routers from Billion Electric have a Missing Authentication vulnerability, allowing unauthenticated remote attackers to directly access the specific functionality to obtain partial device information, modify the WiFi SSID, and restart the device. |
| Telesquare SKT LTE Router SDT-CS3B1 software version 1.2.0 contains an unauthenticated remote reboot vulnerability that allows attackers to trigger device reboot without authentication. Attackers can send POST requests to the lte.cgi endpoint with the Command=Reboot parameter to cause denial of service by forcing the router to restart. |
| A missing authentication for critical function vulnerability has been reported to affect QVR Pro. The remote attackers can then exploit the vulnerability to gain access to the system.
We have already fixed the vulnerability in the following version:
QVR Pro 2.7.4.14 and later |
| OneUptime is an open-source monitoring and observability platform. Prior to version 10.0.42, the Worker service's ManualAPI exposes workflow execution endpoints (GET /workflow/manual/run/:workflowId and POST /workflow/manual/run/:workflowId) without any authentication middleware. An attacker who can obtain or guess a workflow ID can trigger arbitrary workflow execution with attacker-controlled input data, enabling JavaScript code execution, notification abuse, and data manipulation. This issue has been patched in version 10.0.42. |
| A Missing Authentication for Critical Function vulnerability in command processing of Juniper Networks Junos OS allows a privileged local attacker to gain access to Linux-based line cards as root.
This issue affects systems running Junos OS using Linux-based line cards. Affected line cards include:
* MPC7, MPC8, MPC9, MPC10, MPC11
* LC2101, LC2103
* LC480, LC4800, LC9600
* MX304 (built-in FPC)
* MX-SPC3
* SRX5K-SPC3
* EX9200-40XS
* FPC3-PTX-U2, FPC3-PTX-U3
* FPC3-SFF-PTX
* LC1101, LC1102, LC1104, LC1105
This issue affects Junos OS:
* all versions before 22.4R3-S8,
* from 23.2 before 23.2R2-S6,
* from 23.4 before 23.4R2-S6,
* from 24.2 before 24.2R2-S3,
* from 24.4 before 24.4R2,
* from 25.2 before 25.2R2. |
| CLIENT_CERT authentication does not fail as expected for some scenarios when soft fail is disabled vulnerability in Apache Tomcat, Apache Tomcat Native.
This issue affects Apache Tomcat: from 11.0.0-M1 through 11.0.18, from 10.1.0-M7 through 10.1.52, from 9.0.83 through 9.0.115; Apache Tomcat Native: from 1.1.23 through 1.1.34, from 1.2.0 through 1.2.39, from 1.3.0 through 1.3.6, from 2.0.0 through 2.0.13.
Users are recommended to upgrade to version Tomcat Native 1.3.7 or 2.0.14 and Tomcat 11.0.20, 10.1.53 and 9.0.116, which fix the issue. |
| CLIENT_CERT authentication does not fail as expected for some scenarios when soft fail is disabled and FFM is used in Apache Tomcat.
This issue affects Apache Tomcat: from 11.0.0-M14 through 11.0.20, from 10.1.22 through 10.1.53, from 9.0.92 through 9.0.116.
Users are recommended to upgrade to version 11.0.21, 10.1.54 or 9.0.117, which fixes the issue. |
| Missing authentication for critical function in Azure IoT Explorer allows an unauthorized attacker to disclose information over a network. |
| A low-privileged remote attacker can send Modbus packets to manipulate
register values that are inputs to the odorant injection logic such that
too much or too little odorant is injected into a gas line. |