Search

Search Results (409377 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2026-102117 2 Accellion, Kiteworks 2 Kiteworks, Core 2026-10-13 7.2 High
On deployments where the remote-support capability is licensed and enabled, an authenticated System Administrator who also possessed the key protecting the submitted data could redirect the underlying system's outbound support connection to a destination of their choosing. That destination could then have operating-system commands executed on the node and receive their output, potentially resulting in remote code execution with the privileges of a local service account.
CVE-2026-102119 2 Accellion, Kiteworks 2 Kiteworks, Kiteworks Email Protection Gateway 2026-10-13 7.2 High
A path traversal weakness in an optional, non-default administrative feature allowed an authenticated administrator to move files to unintended locations outside the feature's designated directory. This could potentially be leveraged to execute arbitrary code on the underlying system.
CVE-2026-109403 1 Conductor-oss 1 Conductor 2026-10-13 7.3 High
A vulnerability was determined in conductor-oss conductor up to 3.32.5. Affected by this vulnerability is the function A2AService.getAgentCard of the file ai/src/main/java/org/conductoross/conductor/ai/a2a/A2AService.java of the component Agent Card Fetching. Executing a manipulation of the argument agentUrl can lead to server-side request forgery. The attack may be launched remotely. The exploit has been publicly disclosed and may be utilized.
CVE-2026-102136 2 Accellion, Kiteworks 2 Kiteworks, Core 2026-10-13 6.3 Medium
In multi-node deployments, an attacker who had already obtained code execution on one appliance node could submit a value through an internal cluster interface that was written into monitoring configuration on another node without sufficient validation, potentially allowing OS commands to be executed there. Execution was limited to an unprivileged service account on that node.
CVE-2026-102137 2 Accellion, Kiteworks 2 Kiteworks, Core 2026-10-13 4.1 Medium
An authenticated administrator could bypass the content validation applied to an administrative file upload and store a file containing dangerous content on the appliance. This did not by itself result in code execution, which would require a separate vulnerability to run the stored file.
CVE-2026-102138 2 Accellion, Kiteworks 2 Kiteworks, Core 2026-10-13 3.3 Low
An authenticated administrator on a node with an optional, separately licensed gateway role enabled could supply a connector URL that the server retrieved without sufficient validation of its scheme or destination, causing the server to issue requests to internal network services. Exploitation requires the licensed gateway role to be active.
CVE-2026-102140 2 Accellion, Kiteworks 2 Kiteworks, Core 2026-10-13 4.9 Medium
An authenticated administrator could initiate an administrative import using a file whose contents were not fully verified, because the import validated only the file's header rather than the complete file. This could allow unverified or forged content to be accepted and processed, affecting the integrity of the imported data.
CVE-2026-102143 2 Accellion, Kiteworks 2 Kiteworks, Kiteworks Email Protection Gateway 2026-10-13 7.5 High
An unauthenticated attacker could cause a file with attacker-controlled content to be written to the appliance filesystem through an administrative upload handler that did not properly authenticate the request. This did not by itself result in code execution, which would require a separate vulnerability to place the file in an executable location.
CVE-2026-102145 2 Accellion, Kiteworks 2 Kiteworks, Core 2026-10-13 6.6 Medium
An authenticated administrator could cause the server to issue requests to, and interact with, internal network services that are not meant to be reachable through this interface. On its own this did not result in code execution.
CVE-2026-102146 2 Accellion, Kiteworks 2 Kiteworks, Kiteworks Email Protection Gateway 2026-10-13 6.5 Medium
An authenticated Email Protection Gateway administrator holding only limited, delegated permissions could write files with attacker-controlled content to arbitrary locations accessible to the Email Protection Gateway service account. This exceeds the administrator's intended privileges and could be used to alter application files and configuration or to disrupt the availability of the service.
CVE-2026-109152 1 Jbardin 1 Scp.py 2026-10-13 5.4 Medium
A security vulnerability has been detected in jbardin scp.py up to 0.16.1. The impacted element is the function _recv_file/_recv_pushd of the component SCP Receive Handler. The manipulation leads to path traversal. Remote exploitation of the attack is possible. Upgrading to version 0.16.2 is sufficient to resolve this issue. The identifier of the patch is 42fc3aaa71411daed60544e3b40179c1038bed5d. Upgrading the affected component is advised. The vendor was contacted early, responded in a very professional manner and quickly released a fixed version of the affected product.
CVE-2025-40946 1 Siemens 30 Blueplanet 100 Nx3 M8, Blueplanet 100 Tl3 Gen2, Blueplanet 105 Tl3 and 27 more 2026-10-13 8.3 High
A vulnerability has been identified in blueplanet 100 NX3 M8 (All versions), blueplanet 100 TL3 GEN2 (All versions < V6.1.4.9), blueplanet 105 TL3 (All versions < V3.92), blueplanet 105 TL3 GEN2 (All versions < V6.1.4.9), blueplanet 110 TL3 (All versions < V3.92), blueplanet 125 NX3 M10 (All versions), blueplanet 125 TL3 (All versions < V3.92), blueplanet 125 TL3 GEN2 (All versions < V6.1.4.9), blueplanet 137 TL3 (All versions < V3.92), blueplanet 150 TL3 (All versions < V3.92), blueplanet 150 TL3 GEN2 (All versions < V6.1.4.9), blueplanet 155 TL3 (All versions < V3.92), blueplanet 155 TL3 GEN2 (All versions < V6.1.4.9), blueplanet 165 TL3 (All versions < V3.92), blueplanet 165 TL3 GEN2 (All versions < V6.1.4.9), blueplanet 3.0 TL3-60.0 TL3 (All versions), blueplanet 87.0 TL3 (All versions < V3.92), blueplanet 87.0 TL3 GEN2 (All versions < V6.1.4.9), blueplanet 92.0 TL3 (All versions < V3.92), blueplanet 92.0 TL3 GEN2 (All versions < V6.1.4.9), blueplanet gridsave 110 TL3-S (All versions < V3.91), blueplanet gridsave 137 TL3-S (All versions < V3.91), blueplanet gridsave 92.0 TL3-S (All versions < V3.91). A CRC16-based algorithm for generating Technical Service credentials could allow an attacker to derive the credentials from the devices serial number and misuse them to gain unauthorized access.
CVE-2026-63354 2026-10-13 9.6 Critical
Affected devices do not properly validate and sanitize visual marker data contained in imported CSV trace files before rendering it on the Trace page. This could allow an attacker to social engineer an authorized user who holds the function right “Read diagnostics” into importing a specially crafted trace file. Successful exploitation could allow attacker-controlled JavaScript to execute in the user’s browser session and perform PLC operations through the web server within the scope of the user’s authorization.
CVE-2026-109153 1 Mosaicml 1 Composer 2026-10-13 6.3 Medium
A vulnerability was detected in MosaicML Composer up to 0.32.1. This affects the function tarball.extractall of the file composer/utils/checkpoint.py of the component Checkpoint Extraction. The manipulation results in path traversal. The attack can be executed remotely. The vendor was contacted early about this disclosure.
CVE-2026-41125 1 Siemens 29 Blueplanet 100 Nx3 M8, Blueplanet 100 Tl3 Gen2, Blueplanet 105 Tl3 and 26 more 2026-10-13 6 Medium
A vulnerability has been identified in blueplanet 100 NX3 M8 (All versions), blueplanet 100 TL3 GEN2 (All versions), blueplanet 105 TL3 (All versions < V3.92), blueplanet 105 TL3 GEN2 (All versions), blueplanet 110 TL3 (All versions < V3.92), blueplanet 125 NX3 M10 (All versions), blueplanet 125 TL3 (All versions < V3.92), blueplanet 125 TL3 GEN2 (All versions), blueplanet 137 TL3 (All versions < V3.92), blueplanet 150 TL3 (All versions < V3.92), blueplanet 150 TL3 GEN2 (All versions), blueplanet 155 TL3 (All versions < V3.92), blueplanet 155 TL3 GEN2 (All versions), blueplanet 165 TL3 (All versions < V3.92), blueplanet 165 TL3 GEN2 (All versions), blueplanet 87.0 TL3 (All versions < V3.92), blueplanet 87.0 TL3 GEN2 (All versions), blueplanet 92.0 TL3 (All versions < V3.92), blueplanet 92.0 TL3 GEN2 (All versions), blueplanet gridsave 110 TL3-S (All versions < V3.92), blueplanet gridsave 137 TL3-S (All versions < V3.92), blueplanet gridsave 92.0 TL3-S (All versions < V3.92). Improper neutralization of special elements used in an sql command ('sql injection') in KACO Meteor server allows an authorized attacker to elevate privileges over a local network.
CVE-2025-40817 1 Siemens 2 Logo!, Siplus Logo! 2026-10-13 6.5 Medium
A vulnerability has been identified in LOGO! 12/24RCE (6ED1052-1MD08-0BA2) (All versions < V1.84.05), LOGO! 12/24RCEo (6ED1052-2MD08-0BA2) (All versions < V1.84.05), LOGO! 230RCE (6ED1052-1FB08-0BA2) (All versions < V1.84.05), LOGO! 230RCEo (6ED1052-2FB08-0BA2) (All versions < V1.84.05), LOGO! 24CE (6ED1052-1CC08-0BA2) (All versions < V1.84.05), LOGO! 24CEo (6ED1052-2CC08-0BA2) (All versions < V1.84.05), LOGO! 24RCE (6ED1052-1HB08-0BA2) (All versions < V1.84.05), LOGO! 24RCEo (6ED1052-2HB08-0BA2) (All versions < V1.84.05), SIPLUS LOGO! 12/24RCE (6AG1052-1MD08-7BA2) (All versions < V1.84.05), SIPLUS LOGO! 12/24RCEo (6AG1052-2MD08-7BA2) (All versions < V1.84.05), SIPLUS LOGO! 230RCE (6AG1052-1FB08-7BA2) (All versions < V1.84.05), SIPLUS LOGO! 230RCEo (6AG1052-2FB08-7BA2) (All versions < V1.84.05), SIPLUS LOGO! 24CE (6AG1052-1CC08-7BA2) (All versions < V1.84.05), SIPLUS LOGO! 24CEo (6AG1052-2CC08-7BA2) (All versions < V1.84.05), SIPLUS LOGO! 24RCE (6AG1052-1HB08-7BA2) (All versions < V1.84.05), SIPLUS LOGO! 24RCEo (6AG1052-2HB08-7BA2) (All versions < V1.84.05). Affected devices do not conduct certain validations when interacting with them. This could allow an unauthenticated remote attacker to change time of the device, which means the device could behave differently.
CVE-2025-40816 1 Siemens 2 Logo!, Siplus Logo! 2026-10-13 7.6 High
A vulnerability has been identified in LOGO! 12/24RCE (6ED1052-1MD08-0BA2) (All versions < V1.84.05), LOGO! 12/24RCEo (6ED1052-2MD08-0BA2) (All versions < V1.84.05), LOGO! 230RCE (6ED1052-1FB08-0BA2) (All versions < V1.84.05), LOGO! 230RCEo (6ED1052-2FB08-0BA2) (All versions < V1.84.05), LOGO! 24CE (6ED1052-1CC08-0BA2) (All versions < V1.84.05), LOGO! 24CEo (6ED1052-2CC08-0BA2) (All versions < V1.84.05), LOGO! 24RCE (6ED1052-1HB08-0BA2) (All versions < V1.84.05), LOGO! 24RCEo (6ED1052-2HB08-0BA2) (All versions < V1.84.05), SIPLUS LOGO! 12/24RCE (6AG1052-1MD08-7BA2) (All versions < V1.84.05), SIPLUS LOGO! 12/24RCEo (6AG1052-2MD08-7BA2) (All versions < V1.84.05), SIPLUS LOGO! 230RCE (6AG1052-1FB08-7BA2) (All versions < V1.84.05), SIPLUS LOGO! 230RCEo (6AG1052-2FB08-7BA2) (All versions < V1.84.05), SIPLUS LOGO! 24CE (6AG1052-1CC08-7BA2) (All versions < V1.84.05), SIPLUS LOGO! 24CEo (6AG1052-2CC08-7BA2) (All versions < V1.84.05), SIPLUS LOGO! 24RCE (6AG1052-1HB08-7BA2) (All versions < V1.84.05), SIPLUS LOGO! 24RCEo (6AG1052-2HB08-7BA2) (All versions < V1.84.05). Affected devices do not conduct certain validations when interacting with them. This could allow an unauthenticated remote attacker to manipulate the devices IP address, which means the device would not be reachable.
CVE-2025-40815 1 Siemens 2 Logo!, Siplus Logo! 2026-10-13 7.2 High
A vulnerability has been identified in LOGO! 12/24RCE (6ED1052-1MD08-0BA2) (All versions < V1.84.05), LOGO! 12/24RCEo (6ED1052-2MD08-0BA2) (All versions < V1.84.05), LOGO! 230RCE (6ED1052-1FB08-0BA2) (All versions < V1.84.05), LOGO! 230RCEo (6ED1052-2FB08-0BA2) (All versions < V1.84.05), LOGO! 24CE (6ED1052-1CC08-0BA2) (All versions < V1.84.05), LOGO! 24CEo (6ED1052-2CC08-0BA2) (All versions < V1.84.05), LOGO! 24RCE (6ED1052-1HB08-0BA2) (All versions < V1.84.05), LOGO! 24RCEo (6ED1052-2HB08-0BA2) (All versions < V1.84.05), SIPLUS LOGO! 12/24RCE (6AG1052-1MD08-7BA2) (All versions < V1.84.05), SIPLUS LOGO! 12/24RCEo (6AG1052-2MD08-7BA2) (All versions < V1.84.05), SIPLUS LOGO! 230RCE (6AG1052-1FB08-7BA2) (All versions < V1.84.05), SIPLUS LOGO! 230RCEo (6AG1052-2FB08-7BA2) (All versions < V1.84.05), SIPLUS LOGO! 24CE (6AG1052-1CC08-7BA2) (All versions < V1.84.05), SIPLUS LOGO! 24CEo (6AG1052-2CC08-7BA2) (All versions < V1.84.05), SIPLUS LOGO! 24RCE (6AG1052-1HB08-7BA2) (All versions < V1.84.05), SIPLUS LOGO! 24RCEo (6AG1052-2HB08-7BA2) (All versions < V1.84.05). Affected devices do not properly validate the structure of TCP packets in several methods. This could allow an attacker to cause buffer overflows, get control over the instruction counter and run custom code.
CVE-2025-40759 2026-10-13 7.8 High
A vulnerability has been identified in SIMATIC S7-PLCSIM V17 (All versions), SIMATIC STEP 7 V17 (All versions < V17 Update 9), SIMATIC STEP 7 V18 (All versions < V18 Update 6), SIMATIC STEP 7 V19 (All versions < V19 Update 4), SIMATIC STEP 7 V20 (All versions < V20 Update 4), SIMATIC WinCC V17 (All versions < V17 Update 9), SIMATIC WinCC V18 (All versions < V18 Update 6), SIMATIC WinCC V19 (All versions < V19 Update 4), SIMATIC WinCC V20 (All versions < V20 Update 4), SIMOCODE ES V17 (All versions), SIMOCODE ES V18 (All versions), SIMOCODE ES V19 (All versions), SIMOCODE ES V20 (All versions), SIMOTION SCOUT TIA V5.4 (All versions), SIMOTION SCOUT TIA V5.5 (All versions), SIMOTION SCOUT TIA V5.6 (All versions < V5.6 SP1 HF7), SIMOTION SCOUT TIA V5.7 (All versions), SINAMICS Startdrive V17 (All versions), SINAMICS Startdrive V18 (All versions), SINAMICS Startdrive V19 (All versions), SINAMICS Startdrive V20 (All versions), SIRIUS Safety ES V17 (TIA Portal) (All versions), SIRIUS Safety ES V18 (TIA Portal) (All versions), SIRIUS Safety ES V19 (TIA Portal) (All versions), SIRIUS Safety ES V20 (TIA Portal) (All versions), SIRIUS Soft Starter ES V17 (TIA Portal) (All versions), SIRIUS Soft Starter ES V18 (TIA Portal) (All versions), SIRIUS Soft Starter ES V19 (TIA Portal) (All versions), SIRIUS Soft Starter ES V20 (TIA Portal) (All versions), TIA Portal Cloud V17 (All versions), TIA Portal Cloud V18 (All versions), TIA Portal Cloud V19 (All versions < V5.2.1.1), TIA Portal Cloud V20 (All versions < V5.2.2.2). Affected products do not properly sanitize stored security properties when parsing project files. This could allow an attacker to cause a type confusion and execute arbitrary code within the affected application.
CVE-2024-54678 1 Siemens 13 Simatic Pcs Neo, Simatic S7-plcsim, Simatic Step 7 and 10 more 2026-10-13 8.2 High
A vulnerability has been identified in SIMATIC PCS neo V4.1 (All versions), SIMATIC PCS neo V5.0 (All versions), SIMATIC PCS neo V6.0 (All versions < V6.0 SP1 Update 1), SIMATIC S7-PLCSIM V17 (All versions), SIMATIC STEP 7 V17 (All versions < V17 Update 9), SIMATIC STEP 7 V18 (All versions < V18 Update 6), SIMATIC STEP 7 V19 (All versions < V19 Update 4), SIMATIC STEP 7 V20 (All versions < V20 Update 4), SIMATIC WinCC V17 (All versions < V17 Update 9), SIMATIC WinCC V18 (All versions < V18 Update 6), SIMATIC WinCC V19 (All versions < V19 Update 4), SIMATIC WinCC V20 (All versions < V20 Update 4), SIMOCODE ES V17 (All versions), SIMOCODE ES V18 (All versions), SIMOCODE ES V19 (All versions), SIMOCODE ES V20 (All versions), SIMOTION SCOUT TIA V5.4 (All versions), SIMOTION SCOUT TIA V5.5 (All versions), SIMOTION SCOUT TIA V5.6 (All versions < V5.6 SP1 HF7), SIMOTION SCOUT TIA V5.7 (All versions), SINAMICS Startdrive V17 (All versions), SINAMICS Startdrive V18 (All versions), SINAMICS Startdrive V19 (All versions), SINAMICS Startdrive V20 (All versions), SIRIUS Safety ES V17 (TIA Portal) (All versions), SIRIUS Safety ES V18 (TIA Portal) (All versions), SIRIUS Safety ES V19 (TIA Portal) (All versions), SIRIUS Safety ES V20 (TIA Portal) (All versions), SIRIUS Soft Starter ES V17 (TIA Portal) (All versions), SIRIUS Soft Starter ES V18 (TIA Portal) (All versions), SIRIUS Soft Starter ES V19 (TIA Portal) (All versions), SIRIUS Soft Starter ES V20 (TIA Portal) (All versions), TIA Portal Cloud V17 (All versions), TIA Portal Cloud V18 (All versions < V6.3.0.2), TIA Portal Cloud V19 (All versions < V5.2.1.1), TIA Portal Cloud V20 (All versions < V5.2.2.2), TIA Portal Test Suite V20 (All versions < V20 Update 4). Affected products do not properly sanitize Interprocess Communication input received through a Windows Named Pipe accessible to all local users. This could allow an authenticated local attacker to cause a type confusion and execute arbitrary code within the affected application.