Total
358 CVE
| CVE | Vendors | Products | Updated | CVSS v3.1 |
|---|---|---|---|---|
| CVE-2017-13082 | 7 Canonical, Debian, Freebsd and 4 more | 13 Ubuntu Linux, Debian Linux, Freebsd and 10 more | 2025-04-20 | N/A |
| Wi-Fi Protected Access (WPA and WPA2) that supports IEEE 802.11r allows reinstallation of the Pairwise Transient Key (PTK) Temporal Key (TK) during the fast BSS transmission (FT) handshake, allowing an attacker within radio range to replay, decrypt, or spoof frames. | ||||
| CVE-2017-13084 | 7 Canonical, Debian, Freebsd and 4 more | 12 Ubuntu Linux, Debian Linux, Freebsd and 9 more | 2025-04-20 | N/A |
| Wi-Fi Protected Access (WPA and WPA2) allows reinstallation of the Station-To-Station-Link (STSL) Transient Key (STK) during the PeerKey handshake, allowing an attacker within radio range to replay, decrypt, or spoof frames. | ||||
| CVE-2017-0897 | 1 Expressionengine | 1 Expressionengine | 2025-04-20 | N/A |
| ExpressionEngine version 2.x < 2.11.8 and version 3.x < 3.5.5 create an object signing token with weak entropy. Successfully guessing the token can lead to remote code execution. | ||||
| CVE-2017-6026 | 1 Schneider-electric | 4 Modicon M241, Modicon M241 Firmware, Modicon M251 and 1 more | 2025-04-20 | 9.1 Critical |
| A Use of Insufficiently Random Values issue was discovered in Schneider Electric Modicon PLCs Modicon M241, firmware versions prior to Version 4.0.5.11, and Modicon M251, firmware versions prior to Version 4.0.5.11. The session numbers generated by the web application are lacking randomization and are shared between several users. This may allow a current session to be compromised. | ||||
| CVE-2017-1000246 | 1 Pysaml2 Project | 1 Pysaml2 | 2025-04-20 | N/A |
| Python package pysaml2 version 4.4.0 and earlier reuses the initialization vector across encryptions in the IDP server, resulting in weak encryption of data. | ||||
| CVE-2017-13087 | 7 Canonical, Debian, Freebsd and 4 more | 13 Ubuntu Linux, Debian Linux, Freebsd and 10 more | 2025-04-20 | N/A |
| Wi-Fi Protected Access (WPA and WPA2) that support 802.11v allows reinstallation of the Group Temporal Key (GTK) when processing a Wireless Network Management (WNM) Sleep Mode Response frame, allowing an attacker within radio range to replay frames from access points to clients. | ||||
| CVE-2017-10874 | 1 Ntt-east | 2 Pwr-q200, Pwr-q200 Firmware | 2025-04-20 | N/A |
| PWR-Q200 does not use random values for source ports of DNS query packets, which allows remote attackers to conduct DNS cache poisoning attacks. | ||||
| CVE-2017-12361 | 1 Cisco | 1 Jabber | 2025-04-20 | N/A |
| A vulnerability in Cisco Jabber for Windows could allow an unauthenticated, local attacker to access sensitive communications made by the Jabber client. An attacker could exploit this vulnerability to gain information to conduct additional attacks. The vulnerability is due to the way Cisco Jabber for Windows handles random number generation for file folders. An attacker could exploit the vulnerability by fixing the random number data used to establish Secure Sockets Layer (SSL) connections between clients. An exploit could allow the attacker to decrypt secure communications made by the Cisco Jabber for Windows client. Cisco Bug IDs: CSCve44806. | ||||
| CVE-2017-13077 | 7 Canonical, Debian, Freebsd and 4 more | 13 Ubuntu Linux, Debian Linux, Freebsd and 10 more | 2025-04-20 | N/A |
| Wi-Fi Protected Access (WPA and WPA2) allows reinstallation of the Pairwise Transient Key (PTK) Temporal Key (TK) during the four-way handshake, allowing an attacker within radio range to replay, decrypt, or spoof frames. | ||||
| CVE-2017-17910 | 1 Hoermann | 6 Hs5-868-bs, Hs5-868-bs Firmware, Hse1-868-bs and 3 more | 2025-04-20 | N/A |
| On Hoermann BiSecur devices before 2018, a vulnerability can be exploited by recording a single radio transmission. An attacker can intercept an arbitrary radio frame exchanged between a BiSecur transmitter and a receiver to obtain the encrypted packet and the 32-bit serial number. The interception of the one-time pairing process is specifically not required. Due to use of AES-128 with an initial static random value and static data vector (all of this static information is the same across different customers' installations), the attacker can easily derive the utilized encryption key and decrypt the intercepted packet. The key can be verified by decrypting the intercepted packet and checking for known plaintext. Subsequently, an attacker can create arbitrary radio frames with the correct encryption key to control BiSecur garage and entrance gate operators and possibly other BiSecur systems as well ("wireless cloning"). To conduct the attack, a low cost Software Defined Radio (SDR) is sufficient. This affects Hoermann Hand Transmitter HS5-868-BS, HSE1-868-BS, and HSE2-868-BS devices. | ||||
| CVE-2017-7902 | 1 Rockwellautomation | 21 1763-l16awa Series A, 1763-l16awa Series B, 1763-l16bbb Series A and 18 more | 2025-04-20 | N/A |
| A "Reusing a Nonce, Key Pair in Encryption" issue was discovered in Rockwell Automation Allen-Bradley MicroLogix 1100 programmable-logic controllers 1763-L16AWA, Series A and B, Version 16.00 and prior versions; 1763-L16BBB, Series A and B, Version 16.00 and prior versions; 1763-L16BWA, Series A and B, Version 16.00 and prior versions; and 1763-L16DWD, Series A and B, Version 16.00 and prior versions and Allen-Bradley MicroLogix 1400 programmable logic controllers 1766-L32AWA, Series A and B, Version 16.00 and prior versions; 1766-L32BWA, Series A and B, Version 16.00 and prior versions; 1766-L32BWAA, Series A and B, Version 16.00 and prior versions; 1766-L32BXB, Series A and B, Version 16.00 and prior versions; 1766-L32BXBA, Series A and B, Version 16.00 and prior versions; and 1766-L32AWAA, Series A and B, Version 16.00 and prior versions. The affected product reuses nonces, which may allow an attacker to capture and replay a valid request until the nonce is changed. | ||||
| CVE-2017-13088 | 7 Canonical, Debian, Freebsd and 4 more | 13 Ubuntu Linux, Debian Linux, Freebsd and 10 more | 2025-04-20 | N/A |
| Wi-Fi Protected Access (WPA and WPA2) that support 802.11v allows reinstallation of the Integrity Group Temporal Key (IGTK) when processing a Wireless Network Management (WNM) Sleep Mode Response frame, allowing an attacker within radio range to replay frames from access points to clients. | ||||
| CVE-2016-5100 | 1 Froxlor | 1 Froxlor | 2025-04-20 | N/A |
| Froxlor before 0.9.35 uses the PHP rand function for random number generation, which makes it easier for remote attackers to guess the password reset token by predicting a value. | ||||
| CVE-2015-3405 | 7 Debian, Fedoraproject, Ntp and 4 more | 14 Debian Linux, Fedora, Ntp and 11 more | 2025-04-20 | N/A |
| ntp-keygen in ntp 4.2.8px before 4.2.8p2-RC2 and 4.3.x before 4.3.12 does not generate MD5 keys with sufficient entropy on big endian machines when the lowest order byte of the temp variable is between 0x20 and 0x7f and not #, which might allow remote attackers to obtain the value of generated MD5 keys via a brute force attack with the 93 possible keys. | ||||
| CVE-2016-10180 | 1 Dlink | 2 Dwr-932b, Dwr-932b Firmware | 2025-04-20 | 7.5 High |
| An issue was discovered on the D-Link DWR-932B router. WPS PIN generation is based on srand(time(0)) seeding. | ||||
| CVE-2017-13081 | 7 Canonical, Debian, Freebsd and 4 more | 12 Ubuntu Linux, Debian Linux, Freebsd and 9 more | 2025-04-20 | N/A |
| Wi-Fi Protected Access (WPA and WPA2) that supports IEEE 802.11w allows reinstallation of the Integrity Group Temporal Key (IGTK) during the group key handshake, allowing an attacker within radio range to spoof frames from access points to clients. | ||||
| CVE-2017-7901 | 1 Rockwellautomation | 21 1763-l16awa Series A, 1763-l16awa Series B, 1763-l16bbb Series A and 18 more | 2025-04-20 | N/A |
| A Predictable Value Range from Previous Values issue was discovered in Rockwell Automation Allen-Bradley MicroLogix 1100 programmable-logic controllers 1763-L16AWA, Series A and B, Version 16.00 and prior versions; 1763-L16BBB, Series A and B, Version 16.00 and prior versions; 1763-L16BWA, Series A and B, Version 16.00 and prior versions; and 1763-L16DWD, Series A and B, Version 16.00 and prior versions and Allen-Bradley MicroLogix 1400 programmable logic controllers 1766-L32AWA, Series A and B, Version 16.00 and prior versions; 1766-L32BWA, Series A and B, Version 16.00 and prior versions; 1766-L32BWAA, Series A and B, Version 16.00 and prior versions; 1766-L32BXB, Series A and B, Version 16.00 and prior versions; 1766-L32BXBA, Series A and B, Version 16.00 and prior versions; and 1766-L32AWAA, Series A and B, Version 16.00 and prior versions. Insufficiently random TCP initial sequence numbers are generated, which may allow an attacker to predict the numbers from previous values. This may allow an attacker to spoof or disrupt TCP connections, resulting in a denial of service for the target device. | ||||
| CVE-2021-40422 | 1 Swiftsensors | 2 Sg3-1010, Sg3-1010 Firmware | 2025-04-15 | 10 Critical |
| An authentication bypass vulnerability exists in the device password generation functionality of Swift Sensors Gateway SG3-1010. A specially-crafted network request can lead to remote code execution. An attacker can send a sequence of requests to trigger this vulnerability. | ||||
| CVE-2022-3959 | 1 Drogon | 1 Drogon | 2025-04-15 | 3.1 Low |
| A vulnerability, which was classified as problematic, has been found in drogon up to 1.8.1. Affected by this issue is some unknown functionality of the component Session Hash Handler. The manipulation leads to small space of random values. The attack may be launched remotely. Upgrading to version 1.8.2 is able to address this issue. The name of the patch is c0d48da99f66aaada17bcd28b07741cac8697647. It is recommended to upgrade the affected component. The identifier of this vulnerability is VDB-213464. | ||||
| CVE-2021-4240 | 1 Phpservermonitor | 1 Php Server Monitor | 2025-04-15 | 2.6 Low |
| A vulnerability, which was classified as problematic, was found in phpservermon. This affects the function generatePasswordResetToken of the file src/psm/Service/User.php. The manipulation leads to use of predictable algorithm in random number generator. The exploit has been disclosed to the public and may be used. The name of the patch is 3daa804d5f56c55b3ae13bfac368bb84ec632193. It is recommended to apply a patch to fix this issue. The identifier VDB-213717 was assigned to this vulnerability. | ||||