Search Results (311 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2016-8359 1 Moxa 19 Iologik E1200 Series Firmware, Iologik E1210, Iologik E1211 and 16 more 2025-04-20 6.1 Medium
An issue was discovered in Moxa ioLogik E1210, firmware Version V2.4 and prior, ioLogik E1211, firmware Version V2.3 and prior, ioLogik E1212, firmware Version V2.4 and prior, ioLogik E1213, firmware Version V2.5 and prior, ioLogik E1214, firmware Version V2.4 and prior, ioLogik E1240, firmware Version V2.3 and prior, ioLogik E1241, firmware Version V2.4 and prior, ioLogik E1242, firmware Version V2.4 and prior, ioLogik E1260, firmware Version V2.4 and prior, ioLogik E1262, firmware Version V2.4 and prior, ioLogik E2210, firmware versions prior to V3.13, ioLogik E2212, firmware versions prior to V3.14, ioLogik E2214, firmware versions prior to V3.12, ioLogik E2240, firmware versions prior to V3.12, ioLogik E2242, firmware versions prior to V3.12, ioLogik E2260, firmware versions prior to V3.13, and ioLogik E2262, firmware versions prior to V3.12. The web application fails to sanitize user input, which may allow an attacker to inject script or execute arbitrary code (CROSS-SITE SCRIPTING).
CVE-2016-9332 1 Moxa 1 Softcms 2025-04-20 N/A
An issue was discovered in Moxa SoftCMS versions prior to Version 1.6. Moxa SoftCMS Webserver does not properly validate input. An attacker could provide unexpected values and cause the program to crash or excessive consumption of resources could result in a denial-of-service condition.
CVE-2016-8372 1 Moxa 19 Iologik E1200 Series Firmware, Iologik E1210, Iologik E1211 and 16 more 2025-04-20 8.1 High
An issue was discovered in Moxa ioLogik E1210, firmware Version V2.4 and prior, ioLogik E1211, firmware Version V2.3 and prior, ioLogik E1212, firmware Version V2.4 and prior, ioLogik E1213, firmware Version V2.5 and prior, ioLogik E1214, firmware Version V2.4 and prior, ioLogik E1240, firmware Version V2.3 and prior, ioLogik E1241, firmware Version V2.4 and prior, ioLogik E1242, firmware Version V2.4 and prior, ioLogik E1260, firmware Version V2.4 and prior, ioLogik E1262, firmware Version V2.4 and prior, ioLogik E2210, firmware versions prior to V3.13, ioLogik E2212, firmware versions prior to V3.14, ioLogik E2214, firmware versions prior to V3.12, ioLogik E2240, firmware versions prior to V3.12, ioLogik E2242, firmware versions prior to V3.12, ioLogik E2260, firmware versions prior to V3.13, and ioLogik E2262, firmware versions prior to V3.12. A password is transmitted in a format that is not sufficiently secure.
CVE-2016-8712 1 Moxa 2 Awk-3131a, Awk-3131a Firmware 2025-04-20 8.1 High
An exploitable nonce reuse vulnerability exists in the Web Application functionality of Moxa AWK-3131A Wireless AP running firmware 1.1. The device uses one nonce for all session authentication requests and only changes the nonce if the web application has been idle for 300 seconds.
CVE-2016-8725 1 Moxa 2 Awk-3131a, Awk-3131a Firmware 2025-04-20 5.3 Medium
An exploitable information disclosure vulnerability exists in the Web Application functionality of the Moxa AWK-3131A wireless access point running firmware 1.1. Retrieving a specific URL without authentication can reveal sensitive information to an attacker.
CVE-2016-8720 1 Moxa 2 Awk-3131a, Awk-3131a Firmware 2025-04-20 4.3 Medium
An exploitable HTTP Header Injection vulnerability exists in the Web Application functionality of the Moxa AWK-3131A Wireless Access Point running firmware 1.1. A specially crafted HTTP request can inject a payload in the bkpath parameter which will be copied in to Location header of the HTTP response.
CVE-2016-9371 1 Moxa 51 Nport 5100 Series Firmware, Nport 5100a Series Firmware, Nport 5110 and 48 more 2025-04-20 N/A
An issue was discovered in Moxa NPort 5110 versions prior to 2.6, NPort 5130/5150 Series versions prior to 3.6, NPort 5200 Series versions prior to 2.8, NPort 5400 Series versions prior to 3.11, NPort 5600 Series versions prior to 3.7, NPort 5100A Series & NPort P5150A versions prior to 1.3, NPort 5200A Series versions prior to 1.3, NPort 5150AI-M12 Series versions prior to 1.2, NPort 5250AI-M12 Series versions prior to 1.2, NPort 5450AI-M12 Series versions prior to 1.2, NPort 5600-8-DT Series versions prior to 2.4, NPort 5600-8-DTL Series versions prior to 2.4, NPort 6x50 Series versions prior to 1.13.11, NPort IA5450A versions prior to v1.4. User-controlled input is not neutralized before being output to web page (CROSS-SITE SCRIPTING).
CVE-2016-9346 1 Moxa 6 Miineport E1, Miineport E1 Firmware, Miineport E2 and 3 more 2025-04-20 N/A
An issue was discovered in Moxa MiiNePort E1 versions prior to 1.8, E2 versions prior to 1.4, and E3 versions prior to 1.1. Configuration data are stored in a file that is not encrypted.
CVE-2017-7456 1 Moxa 1 Mxview 2025-04-20 N/A
Moxa MXView 2.8 allows remote attackers to cause a Denial of Service by sending overly long junk payload for the MXView client login credentials.
CVE-2016-9354 1 Moxa 1 Dacenter 2025-04-20 N/A
An issue was discovered in Moxa DACenter Versions 1.4 and older. A specially crafted project file may cause the program to crash because of Uncontrolled Resource Consumption.
CVE-2016-9344 1 Moxa 6 Miineport E1, Miineport E1 Firmware, Miineport E2 and 3 more 2025-04-20 N/A
An issue was discovered in Moxa MiiNePort E1 versions prior to 1.8, E2 versions prior to 1.4, and E3 versions prior to 1.1. An attacker may be able to brute force an active session cookie to be able to download configuration files.
CVE-2016-8350 1 Moxa 19 Iologik E1200 Series Firmware, Iologik E1210, Iologik E1211 and 16 more 2025-04-20 6.3 Medium
An issue was discovered in Moxa ioLogik E1210, firmware Version V2.4 and prior, ioLogik E1211, firmware Version V2.3 and prior, ioLogik E1212, firmware Version V2.4 and prior, ioLogik E1213, firmware Version V2.5 and prior, ioLogik E1214, firmware Version V2.4 and prior, ioLogik E1240, firmware Version V2.3 and prior, ioLogik E1241, firmware Version V2.4 and prior, ioLogik E1242, firmware Version V2.4 and prior, ioLogik E1260, firmware Version V2.4 and prior, ioLogik E1262, firmware Version V2.4 and prior, ioLogik E2210, firmware versions prior to V3.13, ioLogik E2212, firmware versions prior to V3.14, ioLogik E2214, firmware versions prior to V3.12, ioLogik E2240, firmware versions prior to V3.12, ioLogik E2242, firmware versions prior to V3.12, ioLogik E2260, firmware versions prior to V3.13, and ioLogik E2262, firmware versions prior to V3.12. The web application may not sufficiently verify whether a request was provided by a valid user (CROSS-SITE REQUEST FORGERY).
CVE-2017-13699 1 Moxa 2 Eds-g512e, Eds-g512e Firmware 2025-04-20 N/A
An issue was discovered on MOXA EDS-G512E 5.1 build 16072215 devices. The password encryption method can be retrieved from the firmware. This encryption method is based on a chall value that is sent in cleartext as a POST parameter. An attacker could reverse the password encryption algorithm to retrieve it.
CVE-2016-8726 1 Moxa 2 Awk-3131a, Awk-3131a Firmware 2025-04-20 7.5 High
An exploitable null pointer dereference vulnerability exists in the Web Application /forms/web_runScript iw_filename functionality of Moxa AWK-3131A Wireless Access Point running firmware 1.1. An HTTP POST request with a blank line in the header will cause a segmentation fault in the web server.
CVE-2017-7915 1 Moxa 12 Oncell 5004-hspa, Oncell 5004-hspa Firmware, Oncell 5104-hsdpa and 9 more 2025-04-20 N/A
An Improper Restriction of Excessive Authentication Attempts issue was discovered in Moxa OnCell G3110-HSPA Version 1.3 build 15082117 and previous versions, OnCell G3110-HSDPA Version 1.2 Build 09123015 and previous versions, OnCell G3150-HSDPA Version 1.4 Build 11051315 and previous versions, OnCell 5104-HSDPA, OnCell 5104-HSPA, and OnCell 5004-HSPA. An attacker can freely use brute force to determine parameters needed to bypass authentication.
CVE-2017-7457 1 Moxa 1 Mx-aopc Server 2025-04-20 N/A
XML External Entity via ".AOP" files used by Moxa MX-AOPC Server 1.5 result in remote file disclosure.
CVE-2017-7455 1 Moxa 1 Mxview 2025-04-20 N/A
Moxa MXView 2.8 allows remote attackers to read web server's private key file, no access control.
CVE-2022-3088 2 Debian, Moxa 129 Debian Linux, Aig-301-ap-azu-lx, Aig-301-ap-azu-lx Firmware and 126 more 2025-04-16 7.8 High
UC-8100A-ME-T System Image: Versions v1.0 to v1.6, UC-2100 System Image: Versions v1.0 to v1.12, UC-2100-W System Image: Versions v1.0 to v 1.12, UC-3100 System Image: Versions v1.0 to v1.6, UC-5100 System Image: Versions v1.0 to v1.4, UC-8100 System Image: Versions v3.0 to v3.5, UC-8100-ME-T System Image: Versions v3.0 and v3.1, UC-8200 System Image: v1.0 to v1.5, AIG-300 System Image: v1.0 to v1.4, UC-8410A with Debian 9 System Image: Versions v4.0.2 and v4.1.2, UC-8580 with Debian 9 System Image: Versions v2.0 and v2.1, UC-8540 with Debian 9 System Image: Versions v2.0 and v2.1, and DA-662C-16-LX (GLB) System Image: Versions v1.0.2 to v1.1.2 of Moxa's ARM-based computers have an execution with unnecessary privileges vulnerability, which could allow an attacker with user-level privileges to gain root privileges.
CVE-2022-3086 1 Moxa 100 Uc-2101-lx, Uc-2101-lx Firmware, Uc-2102-lx and 97 more 2025-04-16 7.1 High
Cradlepoint IBR600 NCOS versions 6.5.0.160bc2e and prior are vulnerable to shell escape, which enables local attackers with non-superuser credentials to gain full, unrestrictive shell access which may allow an attacker to execute arbitrary code.
CVE-2021-32968 1 Moxa 8 Nport Iaw5150a-12i\/o, Nport Iaw5150a-12i\/o Firmware, Nport Iaw5150a-6i\/o and 5 more 2025-04-16 7.5 High
Two buffer overflows in the built-in web server in Moxa NPort IAW5000A-I/O Series firmware version 2.2 or earlier may allow a remote attacker to cause a denial-of-service condition.