| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| The T-Soft E-Commerce 4 web application is susceptible to SQL injection (SQLi) attacks when authenticated as an admin or privileged user. This vulnerability allows attackers to access and manipulate the database through crafted requests. By exploiting this flaw, attackers can bypass authentication mechanisms, view sensitive information stored in the database, and potentially exfiltrate data. |
| Unprotected alternative channel of return branch target prediction in some Intel(R) Processors may allow an authorized user to potentially enable information disclosure via local access. |
| An issue was discovered on certain Nuki Home Solutions devices. The code used to parse the JSON objects received from the WebSocket service provided by the device leads to a stack buffer overflow. An attacker would be able to exploit this to gain arbitrary code execution on a KeyTurner device. This affects Nuki Smart Lock 3.0 before 3.3.5 and 2.0 before 2.12.4, as well as Nuki Bridge v1 before 1.22.0 and v2 before 2.13.2. |
| An issue was discovered on certain Nuki Home Solutions devices. It is possible to send multiple BLE malformed packets to block some of the functionality and reboot the device. This affects Nuki Smart Lock 3.0 before 3.3.5 and Nuki Smart Lock 2.0 before 2.12.4. |
| An issue was discovered on certain Nuki Home Solutions devices. An attacker with physical access to the circuit board could use the SWD debug features to control the execution of code on the processor and debug the firmware, as well as read or alter the content of the internal and external flash memory. This affects Nuki Smart Lock 3.0 before 3.3.5, Nuki Smart Lock 2.0 before 2.12.4, as well as Nuki Bridge v1 before 1.22.0 and v2 before 2.13.2. |
| An issue was discovered on certain Nuki Home Solutions devices. Some BLE commands, which should have been designed to be only called from privileged accounts, could also be called from unprivileged accounts. This demonstrates that no access controls were implemented for the different BLE commands across the different accounts. This affects Nuki Smart Lock 3.0 before 3.3.5 and Nuki Smart Lock 2.0 before 2.12.4. |
| An issue was discovered on certain Nuki Home Solutions devices. By sending a malformed HTTP verb, it is possible to force a reboot of the device. This affects Nuki Bridge v1 before 1.22.0 and v2 before 2.13.2. |
| An issue was discovered on certain Nuki Home Solutions devices. The HTTP API exposed by a Bridge used an unencrypted channel to provide an administrative interface. A token can be easily eavesdropped by a malicious actor to impersonate a legitimate user and gain access to the full set of API endpoints. This affects Nuki Bridge v1 before 1.22.0 and v2 before 2.13.2. |
| IPP software versions prior to v1.71 do not sufficiently verify the authenticity of data, in a
way that causes it to accept invalid data. |
| IPP software prior to v1.71 is vulnerable to default credential vulnerability. This could
lead attackers to identify and access vulnerable systems. |
| A security issue in Sitevision version 10.3.1 and older allows a remote attacker, in certain (non-default) scenarios, to gain access to the private keys used for signing SAML Authn requests. The underlying issue is a Java keystore that may become accessible and downloadable via WebDAV. This keystore is protected with a low-complexity, auto-generated password. |
| Unrestricted Upload of File with Dangerous Type vulnerability in Rometheme RTMKit rometheme-for-elementor.This issue affects RTMKit: from n/a through <= 1.6.5. |
| In BootROM, there is a possible missing validation for Certificate Type 0. This could lead to local escalation of privilege with no additional execution privileges needed. |
| A weak password requirement issue was discovered in Teldats Router RS123, RS123w allows a remote attacker to escalate privileges |
| An authentication bypass vulnerability could allow an attacker to access API functions without authentication. |
| Missing Authorization vulnerability in Aazztech Post Slider.This issue affects Post Slider: from n/a through 1.6.7.
|
|
SAP My Travel Requests does not perform necessary authorization checks for an authenticated user, resulting in escalation of privileges. On successful exploitation, the attacker can upload a malicious attachment to a business trip request which will lead to a low impact on the confidentiality, integrity and availability of the application.
|
| Northern.tech Mender 3.3.x before 3.3.2 and 3.4.x before 3.4.0 has Incorrect Access Control and allows low-privileged users default read access to some sensitive device information. |
| In Kostal PIKO 1.5-1 MP plus HMI OEM p 1.0.1, the web application for the Solar Panel is vulnerable to a Stored Cross-Site Scripting (XSS) attack on /file.bootloader.upload.html. The application fails to sanitize the parameter filename, in a POST request to /file.bootloader.upload.html for a system update, thus allowing one to inject HTML and/or JavaScript on the page that will then be processed and stored by the application. Any subsequent requests to pages that retrieve the malicious content will automatically exploit the vulnerability on the victim's browser. This also happens because the tag is loaded in the function innerHTML in the page HTML. |
| Voltronic Power ViewPower through 1.04-21353 and PowerShield Netguard before 1.04-23292 allows a remote attacker to configure the system via an unspecified web interface. An unauthenticated remote attacker can make changes to the system including: changing the web interface admin password, view/change system configuration, enumerate connected UPS devices and shut down connected UPS devices. This extends to being able to configure operating system commands that should run if the system detects a connected UPS shutting down. |