Filtered by vendor Siemens
Subscriptions
Total
2221 CVE
| CVE | Vendors | Products | Updated | CVSS v3.1 |
|---|---|---|---|---|
| CVE-2016-9158 | 1 Siemens | 21 Simatic S7-300 Cpu 312, Simatic S7-300 Cpu 314, Simatic S7-300 Cpu 315-2 Dp and 18 more | 2025-04-12 | N/A |
| A vulnerability has been identified in SIMATIC S7-300 CPU family (All versions), SIMATIC S7-300 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions), SIMATIC S7-400 PN/DP V6 and below CPU family (incl. SIPLUS variants) (All versions), SIMATIC S7-400 PN/DP V7 CPU family (incl. SIPLUS variants) (All versions), SIMATIC S7-400 V6 and earlier CPU family (All versions), SIMATIC S7-400 V7 CPU family (All versions). Specially crafted packets sent to port 80/tcp could cause the affected devices to go into defect mode. A cold restart is required to recover the system. | ||||
| CVE-2016-8565 | 1 Siemens | 1 Automation License Manager | 2025-04-12 | N/A |
| Siemens Automation License Manager (ALM) before 5.3 SP3 allows remote attackers to write to files, rename files, create directories, or delete directories via crafted packets. | ||||
| CVE-2016-8563 | 1 Siemens | 1 Automation License Manager | 2025-04-12 | N/A |
| Siemens Automation License Manager (ALM) before 5.3 SP3 Update 1 allows remote attackers to cause a denial of service (ALM service outage) via crafted packets to TCP port 4410. | ||||
| CVE-2016-9156 | 1 Siemens | 1 Sicam Pas\/pqs | 2025-04-12 | 7.3 High |
| A vulnerability in Siemens SICAM PAS (all versions before V8.09) could allow a remote attacker to upload, download, or delete files in certain parts of the file system by sending specially crafted packets to port 19235/TCP. | ||||
| CVE-2016-9160 | 1 Siemens | 2 Simatic Pcs 7, Simatic Wincc | 2025-04-12 | N/A |
| A vulnerability in SIEMENS SIMATIC WinCC (All versions < SIMATIC WinCC V7.2) and SIEMENS SIMATIC PCS 7 (All versions < SIMATIC PCS 7 V8.0 SP1) could allow a remote attacker to crash an ActiveX component or leak parts of the application memory if a user is tricked into clicking on a malicious link under certain conditions. | ||||
| CVE-2014-8479 | 1 Siemens | 9 Scalance X-300, Scalance X-300 Series Firmware, Scalance X-300eec and 6 more | 2025-04-12 | N/A |
| The FTP server on Siemens SCALANCE X-300 switches with firmware before 4.0 and SCALANCE X 408 switches with firmware before 4.0 allows remote authenticated users to cause a denial of service (reboot) via crafted FTP packets. | ||||
| CVE-2016-9157 | 1 Siemens | 1 Sicam Pas\/pqs | 2025-04-12 | 9.8 Critical |
| A vulnerability in Siemens SICAM PAS (all versions before V8.09) could allow a remote attacker to cause a Denial of Service condition and potentially lead to unauthenticated remote code execution by sending specially crafted packets to port 19234/TCP. | ||||
| CVE-2016-5848 | 1 Siemens | 1 Sicam Pas\/pqs | 2025-04-12 | 6.7 Medium |
| Siemens SICAM PAS before 8.07 does not properly restrict password data in the database, which makes it easier for local users to calculate passwords by leveraging unspecified database privileges. | ||||
| CVE-2016-5849 | 1 Siemens | 1 Sicam Pas\/pqs | 2025-04-12 | 2.5 Low |
| Siemens SICAM PAS through 8.07 allows local users to obtain sensitive configuration information by leveraging database stoppage. | ||||
| CVE-2015-8214 | 1 Siemens | 8 Simatic Cp 343-1, Simatic Cp 343-1 Firmware, Simatic Cp 443-1 and 5 more | 2025-04-12 | N/A |
| A vulnerability has been identified in SIMATIC NET CP 342-5 (incl. SIPLUS variants) (All versions), SIMATIC NET CP 343-1 Advanced (incl. SIPLUS variants) (All versions < V3.0.44), SIMATIC NET CP 343-1 Lean (incl. SIPLUS variants) (All versions < V3.1.1), SIMATIC NET CP 343-1 Standard (incl. SIPLUS variants) (All versions < V3.1.1), SIMATIC NET CP 443-1 Advanced (incl. SIPLUS variants) (All versions < V3.2.9), SIMATIC NET CP 443-1 Standard (incl. SIPLUS variants) (All versions < V3.2.9), SIMATIC NET CP 443-5 Basic (incl. SIPLUS variants) (All versions), SIMATIC NET CP 443-5 Extended (All versions), TIM 3V-IE / TIM 3V-IE Advanced (incl. SIPLUS NET variants) (All versions < V2.6.0), TIM 3V-IE DNP3 (incl. SIPLUS NET variants) (All versions < V3.1.0), TIM 4R-IE (incl. SIPLUS NET variants) (All versions < V2.6.0), TIM 4R-IE DNP3 (incl. SIPLUS NET variants) (All versions < V3.1.0). The implemented access protection level enforcement of the affected communication processors (CP) could possibly allow unauthenticated users to perform administrative operations on the CPs if network access (port 102/TCP) is available and the CPs' configuration was stored on their corresponding CPUs. | ||||
| CVE-2016-3963 | 1 Siemens | 1 Scalance S613 | 2025-04-12 | N/A |
| Siemens SCALANCE S613 allows remote attackers to cause a denial of service (web-server outage) via traffic to TCP port 443. | ||||
| CVE-2016-2201 | 1 Siemens | 15 Simatic S7-1500 Cpu Firmware, Simatic S7-1511-1 Pn Cpu, Simatic S7-1511c-1 Pn Cpu and 12 more | 2025-04-12 | N/A |
| Siemens SIMATIC S7-1500 CPU devices before 1.8.3 allow remote attackers to bypass a replay protection mechanism via packets on TCP port 102. | ||||
| CVE-2016-8672 | 1 Siemens | 8 Simatic Cp 343-1, Simatic Cp 343-1 Firmware, Simatic Cp 443-1 and 5 more | 2025-04-12 | N/A |
| A vulnerability has been identified in SIMATIC CP 343-1 Advanced (incl. SIPLUS NET variant) (All versions < V3.0.53), SIMATIC CP 443-1 Advanced (incl. SIPLUS NET variant) (All versions < V3.2.17), SIMATIC S7-300 PN/DP CPU family (incl. SIPLUS variants) (All versions), SIMATIC S7-400 PN/DP CPU family (incl. SIPLUS variants) (All versions). The integrated web server delivers cookies without the "secure" flag. Modern browsers interpreting the flag would mitigate potential data leakage in case of clear text transmission. | ||||
| CVE-2015-7974 | 5 Debian, Netapp, Ntp and 2 more | 9 Debian Linux, Clustered Data Ontap, Oncommand Balance and 6 more | 2025-04-12 | 7.7 High |
| NTP 4.x before 4.2.8p6 and 4.3.x before 4.3.90 do not verify peer associations of symmetric keys when authenticating packets, which might allow remote attackers to conduct impersonation attacks via an arbitrary trusted key, aka a "skeleton key." | ||||
| CVE-2016-9155 | 1 Siemens | 30 Ccid1445-dn18, Ccid1445-dn18 Firmware, Ccid1445-dn28 and 27 more | 2025-04-12 | N/A |
| The following SIEMENS branded IP Camera Models CCMW3025, CVMW3025-IR, CFMW3025 prior to version 1.41_SP18_S1; CCPW3025, CCPW5025 prior to version 0.1.73_S1; CCMD3025-DN18 prior to version v1.394_S1; CCID1445-DN18, CCID1445-DN28, CCID1145-DN36, CFIS1425, CCIS1425, CFMS2025, CCMS2025, CVMS2025-IR, CFMW1025, CCMW1025 prior to version v2635_SP1 could allow an attacker with network access to the web server to obtain administrative credentials under certain circumstances. | ||||
| CVE-2016-1488 | 1 Siemens | 4 Ozw672, Ozw672 Firmware, Ozw772 and 1 more | 2025-04-12 | N/A |
| Cross-site scripting (XSS) vulnerability in the login form in the integrated web server on Siemens OZW OZW672 devices before 6.00 and OZW772 devices before 6.00 allows remote attackers to inject arbitrary web script or HTML via a crafted URL. | ||||
| CVE-2016-7090 | 1 Siemens | 4 Scalance M-800, Scalance M-800 Firmware, Scalance S615 and 1 more | 2025-04-12 | N/A |
| The integrated web server on Siemens SCALANCE M-800 and S615 modules with firmware before 4.02 does not set the secure flag for the session cookie in an https session, which makes it easier for remote attackers to capture this cookie by intercepting its transmission within an http session. | ||||
| CVE-2015-4174 | 1 Siemens | 1 Climatix Bacnet\/ip | 2025-04-12 | N/A |
| Cross-site scripting (XSS) vulnerability in the integrated web server on the Siemens Climatix BACnet/IP communication module with firmware before 10.34 allows remote attackers to inject arbitrary web script or HTML via a crafted URL. | ||||
| CVE-2014-4686 | 1 Siemens | 2 Simatic Pcs7, Wincc | 2025-04-12 | N/A |
| The Project administration application in Siemens SIMATIC WinCC before 7.3, as used in PCS7 and other products, has a hardcoded encryption key, which allows remote attackers to obtain sensitive information by extracting this key from another product installation and then employing this key during the sniffing of network traffic on TCP port 1030. | ||||
| CVE-2015-5717 | 1 Siemens | 1 Compas | 2025-04-12 | N/A |
| The Siemens COMPAS Mobile application before 1.6 for Android does not properly verify X.509 certificates from SSL servers, which allows man-in-the-middle attackers to spoof servers and obtain sensitive information via a crafted certificate. | ||||