| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| Emerson ValveLink Products store
sensitive information in cleartext within a resource that might be accessible to another control sphere. |
| A vulnerability has been identified in POWER METER SICAM Q100 (7KG9501-0AA01-0AA1) (All versions >= V2.60 < V2.62), POWER METER SICAM Q100 (7KG9501-0AA01-2AA1) (All versions >= V2.60 < V2.62), POWER METER SICAM Q100 (7KG9501-0AA31-0AA1) (All versions >= V2.60 < V2.62), POWER METER SICAM Q100 (7KG9501-0AA31-2AA1) (All versions >= V2.60 < V2.62), POWER METER SICAM Q200 family (All versions >= V2.70 < V2.80). Affected devices store the password for the SMTP account as plain text. This could allow an authenticated local attacker to extract it and use the configured SMTP service for arbitrary purposes. |
| R Radio Network FM Transmitter 1.07 allows unauthenticated attackers to access the admin user's password through the system.cgi endpoint, enabling authentication bypass and FM station setup access. |
| The Temporal api-go library prior to version 1.44.1 did not send `update response` information to Data Converter when the proxy package within the api-go module was used in a gRPC proxy prior to transmission. This resulted in information contained within the `update response` field not having Data Converter transformations (e.g. encryption) applied. This is an issue only when using the UpdateWorkflowExecution APIs (released on 13th January 2025) with a proxy leveraging the api-go library before version 1.44.1.
Other data fields were correctly sent to Data Converter. This issue does not impact the Data Converter server. Data was encrypted in transit. Temporal Cloud services are not impacted. |
| This vulnerability exists in ZKTeco WL20 due to storage of admin and user credentials without encryption in the device firmware. An attacker with physical access could exploit this vulnerability by extracting the firmware and reverse engineer the binary data to access the unencrypted credentials stored in the firmware of targeted device. |
| Oxide before 6 has unencrypted Control Plane datastores. |
| DuraComm SPM-500 DP-10iN-100-MU
transmits sensitive data without encryption over a channel that could be intercepted by attackers. |
| An issue was discovered on certain Nuki Home Solutions devices. The HTTP API exposed by a Bridge used an unencrypted channel to provide an administrative interface. A token can be easily eavesdropped by a malicious actor to impersonate a legitimate user and gain access to the full set of API endpoints. This affects Nuki Bridge v1 before 1.22.0 and v2 before 2.13.2. |
| This vulnerability exists in Digisol DG-GR6821AC Router due to storage of credentials and PINS without encryption in the device firmware. An attacker with physical access could exploit this vulnerability by extracting the firmware and reverse engineer the binary data to access the unencrypted data stored in the firmware of targeted device.
Successful exploitation of this vulnerability could allow the attacker to gain unauthorized access to the network of the targeted device. |
| On Arista CloudVision Appliance (CVA) affected releases running on appliances that support hardware disk encryption (DCA-350E-CV only), the disk encryption might not be successfully performed. This results in the disks remaining unsecured and data on them |
| When using domain users as BRAIN2 users, communication with Active Directory services is unencrypted. This can lead to the interception of authentication data and compromise confidentiality. |
| A vulnerability classified as problematic was found in Netis WF-2404 1.1.124EN. Affected by this vulnerability is an unknown functionality of the component BusyBox Shell. The manipulation leads to cleartext storage of sensitive information. It is possible to launch the attack on the physical device. The complexity of an attack is rather high. The exploitation appears to be difficult. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way. |
| A vulnerability has been found in Coinomi up to 1.7.6. This issue affects some unknown processing. Such manipulation leads to cleartext transmission of sensitive information. The attack can be launched remotely. This attack is characterized by high complexity. The exploitability is assessed as difficult. The exploit has been disclosed to the public and may be used. The vendor replied with: "(...) there isn't any security implication associated with your findings." |
| A security issue was discovered within the legacy Ansible playbook component of Verve Asset Manager, caused by plaintext secrets incorrectly stored when a playbook is running. This component has been retired and has been optional since the 1.36 release in 2024. |
| A local, low-privileged attacker can learn the password of the connected controller in PLC Designer V4 due to an incorrect implementation that results in the password being displayed in plain text under special conditions. |
| Valmet DNA user passwords in plain text. This practice poses a security risk as attackers who gain access to local project data can read the passwords. |
| A vulnerability has been found in youth-is-as-pale-as-poetry e-learning 1.0. Impacted is the function encryptSecret of the file e-learning-master\exam-api\src\main\java\com\yf\exam\ability\shiro\jwt\JwtUtils.java of the component JWT Token Handler. The manipulation leads to insufficiently random values. The attack can be initiated remotely. The complexity of an attack is rather high. The exploitability is considered difficult. The exploit has been disclosed to the public and may be used. |
| Hathway Skyworth Router CM5100-511 v4.1.1.24 was discovered to store sensitive information about USB and Wifi connected devices in plaintext. |
| Cleartext Storage of Sensitive Information Vulnerability in GX Works2 all versions allows an attacker to disclose credential information stored in plaintext from project files. As a result, the attacker may be able to open project files protected by user authentication using disclosed credential information, and obtain or modify project information. |
| Lack of encryption in transit for cloud infrastructure facilitating potential for sensitive data manipulation or exposure. |