CVE-2024-3798 2026-04-15 N/A
Insecure handling of GET header parameter file included in requests being sent to an instance of the open-source project Phoniebox allows an attacker to create a website, which – when visited by a user – will send malicious requests to multiple hosts on the local network. If such a request reaches the server, it will cause one of the following (depending on the chosen payload): shell command execution, reflected XSS or cross-site request forgery. This issue affects Phoniebox in all releases through 2.7. Newer 2.x releases were not tested, but they might also be vulnerable.  Phoniebox in version 3.0 and higher are not affected.
CVE-2024-0141 2026-04-15 6.8 Medium
NVIDIA Hopper HGX for 8-GPU contains a vulnerability in the GPU vBIOS that may allow a malicious actor with tenant level GPU access to write to an unsupported registry causing a bad state. A successful exploit of this vulnerability may lead to denial of service.
CVE-2025-9494 1 Viessmann 1 Vitogate 300 2026-04-15 N/A
An OS command injection vulnerability has been discovered in the Vitogate 300, which can be exploited by malicious users to compromise affected installations. Specifically, the `/cgi-bin/vitogate.cgi` endpoint is affected, when the `form` JSON parameter is set to `form-0-2`. The vulnerability stems from the fact that that function at offset 0x21c24 does not properly sanitize supplied input before interpolating it into a format string which gets passed to `popen()`. Consequently, an authenticated attacker is able to inject arbitrary OS commands and thus gain code execution on affected devices.
CVE-2025-6104 2026-04-15 8.8 High
A vulnerability, which was classified as critical, was found in Wifi-soft UniBox Controller up to 20250506. This affects an unknown part of the file /billing/pms_check.php. The manipulation of the argument ipaddress leads to os command injection. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-43650 2026-04-15 N/A
Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability in Iocharger firmware for AC models allows OS Command Injection as root This issue affects  firmware versions before 24120701. Likelihood: Moderate – The <redacted> binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a crafted HTTP request. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services. CVSS clarification: The attack can be executed over any network connection serving the web interface (AV:N). There are no additional measures that need to be circumvented (AC:L) or attack preconditions (AT:N). THe attack is privileged, but the level does not matter (PR:L) and does not require user interaction (UI:N). Attack leads to full system compromised (VC:H/VI:H/VA:H) and compromised devices can be used to "pivot" to other networks that should be unreachable (SC:L/SI:L/SA:H). Because this an EV charger using high power, there is a potential safety impact (S:P). The attack can be automated (AU:Y).
CVE-2024-42503 1 Arubanetworks 1 Arubaos 2026-04-15 7.2 High
Authenticated command execution vulnerability exist in the ArubaOS command line interface (CLI). Successful exploitation of this vulnerabilities result in the ability to run arbitrary commands as a priviledge user on the underlying operating system.
CVE-2024-43651 2026-04-15 N/A
Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability allows OS Command Injection as root This issue affects Iocharger firmware for AC models before version 241207101 Likelihood: Moderate – The <redacted> binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a crafted HTTP request. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services. CVSS clarification: Any network connection serving the web interface is vulnerable (AV:N) and there are no additional measures to circumvent (AC:L) nor does the attack require special conditions to be present (AT:N). The attack requires authentication, but the level does not matter (PR:L), nor is user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H) and a compromised device can be used to potentially "pivot" into a network that should nopt be reachable (SC:L/SI:L/SA:H). Because this is an EV charger handing significant power, there is a potential safety impact (S:P). THe attack can be autometed (AU:Y).
CVE-2024-43653 2026-04-15 8.8 High
Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability  allows OS Command Injection as root This issue affects Iocharger firmware for AC model chargers before version 24120701. Likelihood: Moderate – The <redacted> binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a crafted HTTP request. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services. CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y).
CVE-2025-58116 1 Iodata 1 Wn-7d36qr 2026-04-15 7.2 High
Improper neutralization of special elements used in an OS command ('OS Command Injection') issue exists in WN-7D36QR and WN-7D36QR/UE. If this vulnerability is exploited, an arbitrary OS command may be executed by a remote authenticated attacker.
CVE-2024-38512 1 Lenovo 1 Xclarity Controller 2026-04-15 7.2 High
A privilege escalation vulnerability was discovered in XCC that could allow an authenticated XCC user with elevated privileges to perform command injection via specially crafted IPMI commands.
CVE-2024-43654 2026-04-15 8.8 High
Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability in Iocharger firmware for AC models allows OS Command Injection as root This issue affects all Iocharger AC EV charger models on a firmware version before 25010801. Likelihood: Moderate – The <redacted> binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a crafted HTTP request. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services. CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y).
CVE-2025-6562 2026-04-15 8.8 High
Certain hybrid DVR models (HBF-09KD and HBF-16NK) from Hunt Electronic have an OS Command Injection vulnerability, allowing remote attackers with regular privileges to inject arbitrary OS commands and execute them on the device.
CVE-2025-64127 1 Zenitel 1 Tciv-3+ 2026-04-15 10 Critical
An OS command injection vulnerability exists due to insufficient sanitization of user-supplied input. The application accepts parameters that are later incorporated into OS commands without adequate validation. This could allow an unauthenticated attacker to execute arbitrary commands remotely.
CVE-2025-58062 1 Lstm-kirigaya 1 Openmcp-client 2026-04-15 N/A
LSTM-Kirigaya's openmcp-client is a vscode plugin for mcp developer. Prior to version 0.1.12, when users on a Windows platform connect to an attacker controlled MCP server, attackers could provision a malicious authorization server endpoint to silently achieve an OS command injection attack in the open() invocation, leading to client system compromise. This issue has been patched in version 0.1.12.
CVE-2025-64126 1 Zenitel 1 Tciv-3+ 2026-04-15 10 Critical
An OS command injection vulnerability exists due to improper input validation. The application accepts a parameter directly from user input without verifying it is a valid IP address or filtering potentially malicious characters. This could allow an unauthenticated attacker to inject arbitrary commands.
CVE-2024-20356 2026-04-15 8.7 High
A vulnerability in the web-based management interface of Cisco Integrated Management Controller (IMC) could allow an authenticated, remote attacker with Administrator-level privileges to perform command injection attacks on an affected system and elevate their privileges to root. This vulnerability is due to insufficient user input validation. An attacker could exploit this vulnerability by sending crafted commands to the web-based management interface of the affected software. A successful exploit could allow the attacker to elevate their privileges to root.
CVE-2024-28748 1 Ifm 2 Smart Plc Ac14xx Firmware, Smart Plc Ac4xxs Firmware 2026-04-15 7.2 High
A remote attacker with high privileges may use a reading file function to inject OS commands.
CVE-2025-34093 1 Polycom 1 Hdx 2026-04-15 N/A
An authenticated command injection vulnerability exists in the Polycom HDX Series command shell interface accessible over Telnet. The lan traceroute command in the devcmds console accepts unsanitized input, allowing attackers to execute arbitrary system commands. By injecting shell metacharacters through the traceroute interface, an attacker can achieve remote code execution under the context of the root user. This flaw affects systems where Telnet access is enabled and either unauthenticated access is allowed or credentials are known.
CVE-2024-28749 1 Ifm 2 Smart Plc Ac14xx Firmware, Smart Plc Ac4xxs Firmware 2026-04-15 7.2 High
A remote attacker with high privileges may use a writing file function to inject OS commands.
CVE-2025-34099 1 Vicidial 1 Vicidial 2026-04-15 N/A
An unauthenticated command injection vulnerability exists in VICIdial versions 2.9 RC1 through 2.13 RC1, within the vicidial_sales_viewer.php component when password encryption is enabled (a non-default configuration). The application improperly passes the HTTP Basic Authentication password directly to a call to exec() without adequate sanitation. This allows remote attackers to inject and execute arbitrary operating system commands as the web server user. NOTE: This vulnerability was mitigated in 2017.