| EasyFlow .NET and EasyFlow AiNet, developed by Digiwin, has a Missing Authentication vulnerability, allowing unauthenticated remote attackers to obtain database administrator credentials via a specific functionality. |
| A vulnerability was identified in huggingface LeRobot up to 0.3.3. Affected by this vulnerability is an unknown functionality of the file lerobot/common/robot_devices/robots/lekiwi_remote.py of the component ZeroMQ Socket Handler. The manipulation leads to missing authentication. The attack can only be initiated within the local network. The vendor was contacted early about this disclosure but did not respond in any way. |
| In WODESYS WD-R608U router (also known as WDR122B V2.0 and WDR28) due to lack of authentication in the configuration change module in the adm.cgi endpoint, the unauthenticated attacker can execute commands including backup creation, device restart and resetting the device to factory settings.
The vendor was notified early about this vulnerability, but didn't respond with the details of vulnerability or vulnerable version range. Only version WDR28081123OV1.01 was tested and confirmed as vulnerable, other versions were not tested and might also be vulnerable. |
| Simofa is a tool to help automate static website building and deployment. Prior to version 0.2.7, due to a design mistake in the RouteLoader class, some API routes may be publicly accessible when they should require authentication. This vulnerability has been patched in v0.2.7. |
| Dover Fueling Solutions ProGauge MagLink LX Consoles expose an undocumented and unauthenticated target communication framework (TCF) interface on a specific port. Files can be created, deleted, or modified, potentially leading to remote code execution. |
| Remote Control Server, maintained by Steppschuh, 3.1.1.12 allows unauthenticated remote code execution when authentication is disabled, which is the default configuration. The server exposes a custom UDP-based control protocol that accepts remote keyboard input events without verification. An attacker on the same network can issue a sequence of keystroke commands to launch a system shell and execute arbitrary commands, resulting in full system compromise. |
| A vulnerability in the MSC800 allows an unauthenticated attacker to modify the product’s IP
address over Sopas ET.
This can lead to Denial of Service.
Users are recommended to upgrade both
MSC800 and MSC800 LFT to version V4.26 and S2.93.20 respectively which fixes this issue. |
| On IROAD v9 devices, one can Remotely Dump Video Footage and the Live Video Stream. The dashcam exposes endpoints that allow unauthorized users, who gained access through other means, to list and download recorded videos, as well as access live video streams without proper authentication. |
| A local privilege escalation vulnerability exists in lastore-daemon, the system package manager daemon used in Deepin Linux (developed by Wuhan Deepin Technology Co., Ltd.). In versions 0.9.53-1 (Deepin 15.5) and 0.9.66-1 (Deepin 15.7), the D-Bus configuration permits any user in the sudo group to invoke the InstallPackage method without password authentication. By default, the first user created on Deepin is in the sudo group. An attacker with shell access can craft a .deb package containing a malicious post-install script and use dbus-send to install it via lastore-daemon, resulting in arbitrary code execution as root. |
| Missing Authentication for Critical Function vulnerability in GE Vernova Enervista UR Setup application allows Authentication Bypass due to a missing SSH server authentication. Since the client connection is not authenticated, an attacker may perform a man-in-the-middle attack on the network. |
| The
“socket” module provides a pure-Python fallback to the
socket.socketpair() function for platforms that don’t support AF_UNIX,
such as Windows. This pure-Python implementation uses AF_INET or
AF_INET6 to create a local connected pair of sockets. The connection
between the two sockets was not verified before passing the two sockets
back to the user, which leaves the server socket vulnerable to a
connection race from a malicious local peer.
Platforms that support AF_UNIX such as Linux and macOS are not affected by this vulnerability. Versions prior to CPython 3.5 are not affected due to the vulnerable API not being included. |
| A vulnerability was found in whuan132 AIBattery up to 1.0.9. The affected element is an unknown function of the file AIBatteryHelper/XPC/BatteryXPCService.swift of the component com.collweb.AIBatteryHelper. The manipulation results in missing authentication. The attack requires a local approach. The exploit has been made public and could be used. |
| The devices do not implement any authentication for the web interface or the MQTT server. An attacker who has network access to the device immediately gets administrative access to the devices and can perform arbitrary administrative actions and reconfigure the devices or potentially gain access to sensitive data. |
| Due to improper BLE security configurations on the device's GATT server, an adjacent unauthenticated attacker can read and write device control commands through the mobile app service wich could render the device unusable. |
| Missing Authentication for Critical Function vulnerability in ABB ABB AbilityTM zenon.This issue affects ABB AbilityTM zenon: from 7.50 through 14. |
| A device takeover vulnerability exists in the Rockwell Automation Power Monitor 1000. This vulnerability allows configuration of a new Policyholder user without any authentication via API. Policyholder user is the most privileged user that can perform edit operations, creating admin users and performing factory reset. |
| TSA developed by Changing has a Missing Authentication vulnerability, allowing unauthenticated remote attackers to read, modify, and delete database contents. |
| An issue in the Arcadyan Livebox Fibra PRV3399B_B_LT allows a remote or local attacker to modify the GPON link value without authentication, causing an internet service disruption via the /firstconnection.cgi endpoint. |
| A client-side remote code execution vulnerability exists in Hanwha Techwin Smart Security Manager (SSM) versions 1.32 and 1.4, due to improper restrictions on the PUT method exposed by the bundled Apache ActiveMQ instance (running on port 8161). An attacker can exploit this flaw through a Cross-Origin Resource Sharing (CORS) bypass combined with JavaScript-triggered file uploads to the web server, ultimately resulting in arbitrary code execution with SYSTEM privileges.
This vulnerability bypasses the server-side mitigations introduced in ZDI-15-156 and ZDI-16-481 by shifting the exploitation to the client-side.
This product is now referred to as Hanwha Wisenet SSM and it is unknown if current versions are affected. |
| A malicious actor can access camera configuration information, including account credentials, without authenticating when accessing a vulnerable URL. |