| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| A vulnerability has been found in TOZED ZLT M30S and ZLT M30S PRO 1.47/3.09.06. Affected is an unknown function of the component Web Interface. Such manipulation leads to hard-coded credentials. The attack needs to be initiated within the local network. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way. |
| A vulnerability was found in Teledyne FLIR FB-Series O and FLIR FH-Series ID 1.3.2.16. It has been classified as problematic. This affects an unknown part. The manipulation leads to use of hard-coded password. It is possible to initiate the attack remotely. The complexity of an attack is rather high. The exploitability is told to be difficult. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way. |
| A vulnerability was found in shsuishang ShopSuite ModulithShop up to 45a99398cec3b7ad7ff9383694f0b53339f2d35a. Affected by this issue is some unknown functionality of the component RSA/OAuth2/Database. The manipulation results in hard-coded credentials. The attack can be executed remotely. The exploit has been made public and could be used. This product implements a rolling release for ongoing delivery, which means version information for affected or updated releases is unavailable. |
| Use of a hard-coded password for a database administrator account created during Wapro ERP installation allows an attacker to retrieve embedded sensitive data stored in the database. The password is same among all Wapro ERP installations. This issue affects Wapro ERP Desktop versions before 8.90.0. |
| A flaw has been found in Tenda RP3 Pro up to 22.5.7.93. This impacts an unknown function of the file force_upgrade.sh of the component Firmware Update Handler. Executing manipulation of the argument current_force_upgrade_pwd can lead to use of hard-coded password. The attack can only be executed locally. The exploit has been published and may be used. |
| Hardcoded credentials in TerraMaster TOS firmware through 5.1 allow a remote attacker to successfully login to the mail or webmail server. These credentials can also be used to login to the administration panel and to perform privileged actions. |
| Use of hard-coded password issue/vulnerability in SS1 Ver.16.0.0.10 and earlier (Media version:16.0.0a and earlier) allows a remote unauthenticated attacker to view arbitrary files with root privileges. |
| A hard-coded password in the FileCatalyst TransferAgent can be found which can be used to unlock the keystore from which contents may be read out, for example, the private key for certificates. Exploit of this vulnerability could lead to a machine-in-the-middle (MiTM) attack against users of the agent. This issue affects all versions of FileCatalyst Direct from 3.8.10 Build 138 and earlier and all versions of FileCatalyst Workflow from 5.1.6 Build 130 and earlier. |
| On IROAD v9 devices, the dashcam has hardcoded default credentials ("qwertyuiop") that cannot be changed by the user. This allows an attacker within Wi-Fi range to connect to the device's network to perform sniffing. |
| Use of hard-coded password in the GMS ECM endpoint leading to authentication bypass vulnerability.
This issue affects GMS: 9.3.4 and earlier versions.
|
| DYMO LabelWriter Print Server through 2.366 contains a backdoor hard-coded password that could allow an attacker to take control. |
| FydeOS for PC 17.1 R114, FydeOS for VMware 17.0 R114, FydeOS for You 17.1 R114, and OpenFyde R114 were discovered to be configured with the root password saved as a wildcard. This allows attackers to gain root access without a password. |
| runofast Indoor Security Camera for Baby Monitor has a default password of password for the root account. This allows access to the /stream1 URI via the rtsp:// protocol to receive the video and audio stream. |
| A use of hard-coded password vulnerability may allow authentication abuse.This issue affects ELI 380 Resting Electrocardiograph:
Versions 2.6.0 and prior; ELI 280/BUR280/MLBUR 280 Resting Electrocardiograph:
Versions 2.3.1 and prior; ELI 250c/BUR 250c Resting Electrocardiograph:
Versions 2.1.2 and prior; ELI 150c/BUR 150c/MLBUR 150c Resting Electrocardiograph:
Versions 2.2.0 and prior. |
| A vulnerability exists in the message queueing mechanism that if
exploited can lead to the exposure of resources or functionality to
unintended actors, possibly providing attackers with sensitive information or even execute arbitrary code. |
| The Chirp Access app contains a hard-coded password, BEACON_PASSWORD. An attacker within Bluetooth range could change configuration settings within the Bluetooth beacon, effectively disabling the application's ability to notify users when they are near a Beacon-enabled access point. This variable cannot be used to change the configuration settings of the door readers or locksets and does not affect the ability for authorized users of the mobile application to lock or unlock access points. |
| A vulnerability was identified in SUR-FBD CMMS where hard-coded credentials were found within a compiled DLL file. These credentials correspond to a built-in administrative account of the software. An attacker with local access to the system or the application's installation directory could extract these credentials, potentially leading to a complete compromise of the application's administrative functions. This issue was fixed in version 2025.03.27 of the SUR-FBD CMMS software. |
| Tenda G1V3.1si V16.01.7.8 Firmware V16.01.7.8 was discovered to contain a hardcoded password vulnerability in /etc_ro/shadow, which allows attackers to log in as root. |
| Tenda i24V3.0si V3.0.0.5 Firmware V3.0.0.5 was discovered to contain a hardcoded password vulnerability in /etc_ro/shadow, which allows attackers to log in as root. |
| Hardcoded Password Vulnerability have been found in CENTUM. Affected products contain a hardcoded password for the user account (PROG) used for CENTUM Authentication Mode within the system. Under the following conditions, there is a risk that an attacker could log in as the PROG user.
The default permission for the PROG users is S1 permission (equivalent to OFFUSER). Therefore, for properly permission-controlled targets of operation and monitoring, even if an attacker user in as the PROG user, the risk of critical operations or configuration changes being performed is considered low. (If the PROG user's permissions have been changed for any reason, there is a risk that operations or configuration changes may be performed under the modified permissions. The CVSS values below are for the default permissions.)
Additionally, exploiting this vulnerability requires an attacker to already have access to the HIS screen controls. Therefore, an attacker can already operate and monitor at that point, regardless of this vulnerability.
The conditions under which this vulnerability is exploited:
If all of the following conditions are met, the affected products are vulnerable to this vulnerability.
-An attacker obtains the hardcoded password using a certain method.
-The HIS with the affected product installed is configured in CTM authentication mode.
-An attacker must have direct access to the aforementioned HIS or be able to break into it remotely using a certain method and perform screen operations.
The affected products and versions are as follows: CENTUM VP R5.01.00 to R5.04.20, R6.01.00 to R6.12.00 and R7.01.00. |