| MOBATIME Network Master Clock - DTS 4801 allows attackers to use SSH to gain initial access using default credentials. |
| A CWE-1392 “Use of Default Credentials” was discovered affecting the 130.8005 TCP/IP Gateway running firmware version 12h. The device exposes an FTP server with default and easy-to-guess admin credentials. A remote attacker capable of interacting with the FTP server could gain access and perform changes over resources exposed by the service such as configuration files where password hashes are saved or where network settings are stored. |
| A vulnerability was found in Thinkware Car Dashcam F800 Pro up to 20250226. It has been declared as problematic. This vulnerability affects unknown code of the component Device Registration Handler. The manipulation leads to use of default credentials. It is possible to launch the attack on the physical device. The complexity of an attack is rather high. The exploitation appears to be difficult. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way. |
| ANCHOR from Global Wisdom Software is an integrated product running on a Windows virtual machine. The underlying Windows OS of the product contains high-privilege service accounts. If these accounts use default passwords, attackers could remotely log in to the virtual machine using the default credentials. |
| Legacy Vivotek Device firmware uses default credetials for the root and user login accounts. |
| Authentication credentials leakage vulnerability in Hitachi Ops Center Analyzer viewpoint.This issue affects Hitachi Ops Center Analyzer viewpoint: from 10.0.0-00 before 11.0.4-00. |
| Hitachi Ops Center Common Services within Hitachi Ops Center Analyzer viewpoint OVF contains an authentication credentials leakage vulnerability.This issue affects Hitachi Ops Center Common Services: from 10.0.0-00 before 11.0.0-04; Hitachi Ops Center Analyzer viewpoint OVF: from 10.0.0-00 before 11.0.0-04. |
| Adtec Digital SignEdje Digital Signage Player v2.08.28 contains multiple hardcoded default credentials that allow unauthenticated remote access to web, telnet, and SSH interfaces. Attackers can exploit these credentials to gain root-level access and execute system commands across multiple Adtec Digital product versions. |
| Control-M/Agents use a kdb or PKCS#12 keystore by default, and the default keystore password is well known and documented.
An attacker with read access to the keystore could access sensitive data using this password. |
| NetBird VPN when installed using vendor's provided script failed to remove or change default password of an admin account created by ZITADEL.
This issue affects instances installed using vendor's provided script. This issue may affect instances created with Docker if the default password was not changed nor the user was removed.
This issue has been fixed in version 0.57.0 |
| CWE-1392: Use of Default Credentials |
| A vulnerability in the Eclipse Vert.x toolkit causes a memory leak in TCP servers configured with TLS and SNI support. When processing an unknown SNI server name assigned the default certificate instead of a mapped certificate, the SSL context is erroneously cached in the server name map, leading to memory exhaustion. This flaw allows attackers to send TLS client hello messages with fake server names, triggering a JVM out-of-memory error. |
| A vulnerability classified as problematic was found in SAFECAM X300 up to 20250611. This vulnerability affects unknown code of the component FTP Service. The manipulation leads to use of default credentials. Access to the local network is required for this attack to succeed. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way. |
| Default credentials vulnerability exists in SuprOS
product. If exploited, this could allow an authenticated
local attacker to use an admin account created during
product deployment. |
| A vulnerability was identified in TRENDnet TI-G160i, TI-PG102i and TPL-430AP up to 20250724. This affects an unknown part of the component SSH Service. The manipulation leads to use of default credentials. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The real existence of this vulnerability is still doubted at the moment. The vendor explains: "For product TI-PG102i and TI-G160i, by default, the product's remote management options are all disabled. The root account is for troubleshooting purpose and the password is encrypted. However, we will remove the root account from the next firmware release. For product TPL-430AP, the initial setup process requires user to set the password for the management GUI. Once that was done, the default password will be invalid." |
| Default credentials are used in the above listed BD Diagnostic Solutions products. If exploited, threat actors may be able to access, modify or delete data, including sensitive information such as protected health information (PHI) and personally identifiable information (PII). Exploitation of this vulnerability may allow an attacker to shut down or otherwise impact the availability of the system. Note: BD Synapsys™ Informatics
Solution is only in scope of
this vulnerability when
installed on a NUC server. BD Synapsys™
Informatics Solution installed
on a customer-provided virtual machine or on the BD Kiestra™ SCU hardware is
not in scope. |
| iMonitor EAM 9.6394 ships with default administrative credentials that are also displayed within the management client’s connection dialog. If the administrator does not change these defaults, a remote attacker can authenticate to the EAM server and gain full control over monitored agents and data. This enables reading highly sensitive telemetry (including keylogger output) and issuing arbitrary actions to all connected clients. |
| Gardyn Home Kit firmware before master.619, Home Kit Mobile Application before 2.11.0, and Home Kit Cloud API before 2.12.2026 use weak default credentials for secure shell access. This may result in attackers gaining access to exposed Gardyn Home Kits. |
| A credential management flaw in Palo Alto Networks Cortex XDR® Broker VM causes different Broker VM images to share identical default credentials for internal services. Users knowing these default credentials could access internal services on other Broker VM installations.
The attacker must have network access to the Broker VM to exploit this issue. |
| IO-1020 Micro ELD uses a default WIFI password that could allow an adjacent attacker to connect to the device.
|