Search Results (27025 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2025-34115 1 Op5 1 Monitor 2026-04-15 N/A
An authenticated command injection vulnerability exists in OP5 Monitor through version 7.1.9 via the 'cmd_str' parameter in the command_test.php endpoint. A user with access to the web interface can exploit the 'Test this command' feature to execute arbitrary shell commands as the unprivileged web application user. The vulnerability resides in the configuration section of the application and requires valid login credentials with access to the command testing functionality. This issue is fixed in version 7.2.0.
CVE-2024-0615 2 Codeatlantic, Wordpress 2 Content Control, Wordpress 2026-04-15 5.3 Medium
The Content Control – The Ultimate Content Restriction Plugin! Restrict Content, Create Conditional Blocks & More plugin for WordPress is vulnerable to Sensitive Information Exposure in all versions up to, and including, 2.1.0 via the API. This makes it possible for unauthenticated attackers to extract post titles, IDs, slugs, statuses and other information including post content. This includes published content only.
CVE-2025-34113 1 Tiki 1 Tikiwiki Cms\/groupware 2026-04-15 N/A
An authenticated command injection vulnerability exists in Tiki Wiki CMS versions ≤14.1, ≤12.4 LTS, ≤9.10 LTS, and ≤6.14 via the `viewmode` GET parameter in `tiki-calendar.php`. When the calendar module is enabled and an authenticated user has permission to access it, an attacker can inject and execute arbitrary PHP code. Successful exploitation leads to remote code execution in the context of the web server user.
CVE-2025-34105 1 Flexense 1 Diskboss 2026-04-15 N/A
A stack-based buffer overflow vulnerability exists in the built-in web interface of DiskBoss Enterprise versions 7.4.28, 7.5.12, and 8.2.14. The vulnerability arises from improper bounds checking on the path component of HTTP GET requests. By sending a specially crafted long URI, a remote unauthenticated attacker can trigger a buffer overflow, potentially leading to arbitrary code execution with SYSTEM privileges on vulnerable Windows hosts.
CVE-2025-34100 2026-04-15 N/A
An unrestricted file upload vulnerability exists in BuilderEngine 3.5.0 via the integration of the elFinder 2.0 file manager and its use of the jQuery File Upload plugin. The plugin fails to properly validate or restrict file types or locations during upload operations, allowing an attacker to upload a malicious .php file and subsequently execute arbitrary PHP code on the server under the context of the web server process. While the root vulnerability lies within the jQuery File Upload component, BuilderEngine’s improper integration and lack of access controls expose this functionality to unauthenticated users, resulting in full remote code execution.
CVE-2025-40653 2026-04-15 N/A
User enumeration vulnerability in M3M Printer Server Web. This issue occurs during user authentication, where a difference in error messages could allow an attacker to determine whether a username is valid or not, allowing a brute force attack on valid usernames.
CVE-2025-48064 2026-04-15 3.3 Low
GitHub Desktop is an open-source, Electron-based GitHub app designed for git development. Prior to version 3.4.20-beta3, an attacker convincing a user to view a file in a commit of their making in the history view can cause information disclosure by means of Git attempting to access a network share. This affects GitHub Desktop users on Windows that view malicious commits in the history view. macOS users are not affected. When viewing a file diff in the history view GitHub Desktop will call `git log` or `git diff` with the object id (SHA) of the commit, the name of the file, and the old name of the file if the file has been renamed. As a security precaution Git will attempt to fully resolve the old and new path via `realpath`, traversing symlinks, to ensure that the resolved paths reside within the repository working directory. This can lead to Git attempting to access a path that resides on a network share (UNC path) and in doing so Windows will attempt to perform NTLM authentication which passes information such as the computer name, the currently signed in (Windows) user name, and an NTLM hash. GitHub Desktop 3.4.20 and later fix this vulnerability. The beta channel includes the fix in 3.4.20-beta3. As a workaround to use until upgrading is possible, only browse commits in the history view that comes from trusted sources.
CVE-2025-68667 1 Continuwuity 1 Continuwuity 2026-04-15 N/A
Conduit is a chat server powered by Matrix. A vulnerability that affects a number of Conduit-derived homeservers allows a remote, unauthenticated attacker to force the target server to cryptographically sign arbitrary membership events. Affected products include Conduit prior to version 0.10.10, continuwuity prior to version 0.5.0, Grapevine prior to commit `9a50c244`, and tuwunel prior to version 1.4.8. The flaw exists because the server fails to validate the origin of a signing request, provided the event's state_key is a valid user ID belonging to the target server. Attackers can forge "leave" events for any user on the target server. This forcibly removes users (including admins and bots) from rooms. This allows denial of service and/or the removal of technical protections for a room (including policy servers, if all users on the policy server are removed). Attackers can forge "invite" events from a victim user to themselves, provided they have an account on a server where there is an account that has the power level to send invites. This allows the attacker to join private or invite-only rooms accessible by the victim, exposing confidential conversation history and room state. Attackers can forge "ban" events from a victim user to any user below the victim user's power level, provided the victim has the power level to issue bans AND the target of the ban resides on the same server as the victim. This allows the attacker to ban anyone in a room who is on the same server as the vulnerable one, however cannot exploit this to ban users on other servers or the victim themself. Conduit fixes the issue in version 0.10.10. continuwuity fixes the issue in commits `7fa4fa98` and `b2bead67`, released in 0.5.0. tuwunel fixes the issue in commit `dc9314de1f8a6e040c5aa331fe52efbe62e6a2c3`, released in 1.4.8. Grapevine fixes the issue in commit `9a50c2448abba6e2b7d79c64243bb438b351616c`. As a workaround, block access to the `PUT /_matrix/federation/v2/invite/{roomId}/{eventId}` endpoint using your reverse proxy.
CVE-2024-25290 1 Casa Systems 1 Nl1901acv 2026-04-15 8 High
An issue in Casa Systems NL1901ACV R6B032 allows a remote attacker to execute arbitrary code via the userName parameter of the add function.
CVE-2025-0037 2026-04-15 6.6 Medium
In AMD Versal Adaptive SoC devices, the lack of address validation when executing PLM runtime services through the PLM firmware can allow access to isolated or protected memory spaces, resulting in the loss of integrity and confidentiality.
CVE-2025-0051 1 Purestorage 1 Flasharray 2026-04-15 N/A
Improper input validation performed during the authentication process of FlashArray could lead to a system Denial of Service.
CVE-2024-4467 1 Redhat 7 Advanced Virtualization, Container Native Virtualization, Enterprise Linux and 4 more 2026-04-15 7.8 High
A flaw was found in the QEMU disk image utility (qemu-img) 'info' command. A specially crafted image file containing a `json:{}` value describing block devices in QMP could cause the qemu-img process on the host to consume large amounts of memory or CPU time, leading to denial of service or read/write to an existing external file.
CVE-2024-12140 2026-04-15 4.3 Medium
The Elementor Addons AI Addons – 70 Widgets, Premium Templates, Ultimate Elements plugin for WordPress is vulnerable to Information Exposure in all versions up to, and including, 2.2.1 via the render function due to insufficient restrictions on which templates can be included. This makes it possible for authenticated attackers, with Contributor-level access and above, to extract data from private or draft templates that they should not have access to.
CVE-2024-35223 1 Dapr 1 Dapr 2026-04-15 5.3 Medium
Dapr is a portable, event-driven, runtime for building distributed applications across cloud and edge. Dapr sends the app token of the invoker app instead of the app token of the invoked app. This causes of a leak of the application token of the invoker app to the invoked app when using Dapr as a gRPC proxy for remote service invocation. This vulnerability impacts Dapr users who use Dapr as a gRPC proxy for remote service invocation as well as the Dapr App API token functionality. An attacker could exploit this vulnerability to gain access to the app token of the invoker app, potentially compromising security and authentication mechanisms. This vulnerability was patched in version 1.13.3.
CVE-2024-35343 1 Anpviz 17 Ipc-b850 Firmware, Ipc-d250 Firmware, Ipc-d260 Firmware and 14 more 2026-04-15 9.8 Critical
Certain Anpviz products allow unauthenticated users to download arbitrary files from the device's filesystem via a HTTP GET request to the /playback/ URI. This affects IPC-D250, IPC-D260, IPC-B850, IPC-D850, IPC-D350, IPC-D3150, IPC-D4250, IPC-D380, IPC-D880, IPC-D280, IPC-D3180, MC800N, YM500L, YM800N_N2, YMF50B, YM800SV2, YM500L8, and YM200E10 (IP Cameras) firmware v3.2.2.2 and lower and possibly more vendors/models of IP camera.
CVE-2023-52237 1 Siemens 80 Ruggedcom I800, Ruggedcom I800nc, Ruggedcom I801 and 77 more 2026-04-15 7.5 High
A vulnerability has been identified in RUGGEDCOM i800, RUGGEDCOM i800NC, RUGGEDCOM i801, RUGGEDCOM i801NC, RUGGEDCOM i802, RUGGEDCOM i802NC, RUGGEDCOM i803, RUGGEDCOM i803NC, RUGGEDCOM M2100, RUGGEDCOM M2100NC, RUGGEDCOM M2200, RUGGEDCOM M2200NC, RUGGEDCOM M969, RUGGEDCOM M969NC, RUGGEDCOM RMC30, RUGGEDCOM RMC30NC, RUGGEDCOM RMC8388 V4.X, RUGGEDCOM RMC8388 V5.X, RUGGEDCOM RMC8388NC V4.X, RUGGEDCOM RMC8388NC V5.X, RUGGEDCOM RP110, RUGGEDCOM RP110NC, RUGGEDCOM RS1600, RUGGEDCOM RS1600F, RUGGEDCOM RS1600FNC, RUGGEDCOM RS1600NC, RUGGEDCOM RS1600T, RUGGEDCOM RS1600TNC, RUGGEDCOM RS400, RUGGEDCOM RS400NC, RUGGEDCOM RS401, RUGGEDCOM RS401NC, RUGGEDCOM RS416, RUGGEDCOM RS416NC, RUGGEDCOM RS416NCv2 V4.X, RUGGEDCOM RS416NCv2 V5.X, RUGGEDCOM RS416P, RUGGEDCOM RS416PNC, RUGGEDCOM RS416PNCv2 V4.X, RUGGEDCOM RS416PNCv2 V5.X, RUGGEDCOM RS416Pv2 V4.X, RUGGEDCOM RS416Pv2 V5.X, RUGGEDCOM RS416v2 V4.X, RUGGEDCOM RS416v2 V5.X, RUGGEDCOM RS8000, RUGGEDCOM RS8000A, RUGGEDCOM RS8000ANC, RUGGEDCOM RS8000H, RUGGEDCOM RS8000HNC, RUGGEDCOM RS8000NC, RUGGEDCOM RS8000T, RUGGEDCOM RS8000TNC, RUGGEDCOM RS900, RUGGEDCOM RS900 (32M) V4.X, RUGGEDCOM RS900 (32M) V5.X, RUGGEDCOM RS900G, RUGGEDCOM RS900G (32M) V4.X, RUGGEDCOM RS900G (32M) V5.X, RUGGEDCOM RS900GNC, RUGGEDCOM RS900GNC(32M) V4.X, RUGGEDCOM RS900GNC(32M) V5.X, RUGGEDCOM RS900GP, RUGGEDCOM RS900GPNC, RUGGEDCOM RS900L, RUGGEDCOM RS900LNC, RUGGEDCOM RS900M-GETS-C01, RUGGEDCOM RS900M-GETS-XX, RUGGEDCOM RS900M-STND-C01, RUGGEDCOM RS900M-STND-XX, RUGGEDCOM RS900MNC-GETS-C01, RUGGEDCOM RS900MNC-GETS-XX, RUGGEDCOM RS900MNC-STND-XX, RUGGEDCOM RS900MNC-STND-XX-C01, RUGGEDCOM RS900NC, RUGGEDCOM RS900NC(32M) V4.X, RUGGEDCOM RS900NC(32M) V5.X, RUGGEDCOM RS900W, RUGGEDCOM RS910, RUGGEDCOM RS910L, RUGGEDCOM RS910LNC, RUGGEDCOM RS910NC, RUGGEDCOM RS910W, RUGGEDCOM RS920L, RUGGEDCOM RS920LNC, RUGGEDCOM RS920W, RUGGEDCOM RS930L, RUGGEDCOM RS930LNC, RUGGEDCOM RS930W, RUGGEDCOM RS940G, RUGGEDCOM RS940GNC, RUGGEDCOM RS969, RUGGEDCOM RS969NC, RUGGEDCOM RSG2100, RUGGEDCOM RSG2100 (32M) V4.X, RUGGEDCOM RSG2100 (32M) V5.X, RUGGEDCOM RSG2100NC, RUGGEDCOM RSG2100NC(32M) V4.X, RUGGEDCOM RSG2100NC(32M) V5.X, RUGGEDCOM RSG2100P, RUGGEDCOM RSG2100P (32M) V4.X, RUGGEDCOM RSG2100P (32M) V5.X, RUGGEDCOM RSG2100PNC, RUGGEDCOM RSG2100PNC (32M) V4.X, RUGGEDCOM RSG2100PNC (32M) V5.X, RUGGEDCOM RSG2200, RUGGEDCOM RSG2200NC, RUGGEDCOM RSG2288 V4.X, RUGGEDCOM RSG2288 V5.X, RUGGEDCOM RSG2288NC V4.X, RUGGEDCOM RSG2288NC V5.X, RUGGEDCOM RSG2300 V4.X, RUGGEDCOM RSG2300 V5.X, RUGGEDCOM RSG2300NC V4.X, RUGGEDCOM RSG2300NC V5.X, RUGGEDCOM RSG2300P V4.X, RUGGEDCOM RSG2300P V5.X, RUGGEDCOM RSG2300PNC V4.X, RUGGEDCOM RSG2300PNC V5.X, RUGGEDCOM RSG2488 V4.X, RUGGEDCOM RSG2488 V5.X, RUGGEDCOM RSG2488NC V4.X, RUGGEDCOM RSG2488NC V5.X, RUGGEDCOM RSG907R, RUGGEDCOM RSG908C, RUGGEDCOM RSG909R, RUGGEDCOM RSG910C, RUGGEDCOM RSG920P V4.X, RUGGEDCOM RSG920P V5.X, RUGGEDCOM RSG920PNC V4.X, RUGGEDCOM RSG920PNC V5.X, RUGGEDCOM RSL910, RUGGEDCOM RSL910NC, RUGGEDCOM RST2228, RUGGEDCOM RST2228P, RUGGEDCOM RST916C, RUGGEDCOM RST916P. The web server of the affected devices allow a low privileged user to access hashes and password salts of all system's users, including admin users. An attacker could use the obtained information to brute force the passwords offline.
CVE-2024-36053 1 Linuxmint 1 Mintupload 2026-04-15 9 Critical
In the mintupload package through 4.2.0 for Linux Mint, service-name mishandling leads to command injection via shell metacharacters in check_connection, drop_data_received_cb, and Service.remove. A user can modify a service name in a ~/.linuxmint/mintUpload/services/service file.
CVE-2025-49653 2026-04-15 8 High
Exposure of sensitive data in active sessions in Lablup's BackendAI allows attackers to retrieve credentials for users on the management platform.
CVE-2025-57839 1 Honor 1 Magicos 2026-04-15 4 Medium
Photo module is affected by information leak vulnerability, successful exploitation of this vulnerability may affect service confidentiality.
CVE-2024-9875 1 Okta 1 Privileged Access Server Agent Sftd 2026-04-15 7.1 High
Okta Privileged Access server agent (SFTD) versions 1.82.0 to 1.84.0 are affected by a privilege escalation vulnerability when the sudo command bundles feature is enabled. To remediate this vulnerability, upgrade the Okta Privileged Access server agent (SFTD) to version 1.87.1 or greater.