| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| Bosscomm IF740 Firmware versions:11001.7078 & v11001.0000 and System versions: 6.25 & 6.00 were discovered to store passwords in cleartext. |
| Unchecked return value in firmware for some Intel(R) CSME may allow an unauthenticated user to potentially enable escalation of privilege via physical access. |
| Asus RT-N12+ B1 router stores credentials in cleartext, which could allow local attackers to obtain unauthorized access and modify router settings. |
| A flaw has been found in Tenda RP3 Pro up to 22.5.7.93. This impacts an unknown function of the file force_upgrade.sh of the component Firmware Update Handler. Executing manipulation of the argument current_force_upgrade_pwd can lead to use of hard-coded password. The attack can only be executed locally. The exploit has been published and may be used. |
| Elevation of privilege vulnerability in GE HealthCare EchoPAC products |
| NVIDIA GPU Display Driver for Windows contains a vulnerability in the kernel mode layer when the driver is performing an operation at a privilege level that is higher than the minimum level required. A successful exploit of this vulnerability may lead to code execution, denial of service, escalation of privileges, information disclosure, and data tampering. |
| Incorrect Access Control vulnerability in ZLMediaKit versions 1.0 through 8.0, allows remote attackers to escalate privileges and obtain sensitive information. The application system enables the http API interface by default and uses the secret parameter method to authenticate the http restful api interface, but the secret is hardcoded by default. |
| Westermo EDW-100 devices through 2024-05-03 allow an unauthenticated user to download a configuration file containing a cleartext password. NOTE: this is a serial-to-Ethernet converter that should not be placed at the edge of the network. |
| Attackers can then execute malicious files by enabling certain services of the printer via the web configuration page and elevate its privileges to root. As for the affected products/models/versions, see the reference URL. |
| An issue in Debezium Community debezium-ui v.2.5 allows a local attacker to execute arbitrary code via the refresh page function. |
| Due to a missing authentication check in the SAP NetWeaver application on IBM i-series, the application allows high privileged unauthorized users to read, modify, or delete sensitive information, as well as access administrative or privileged functionalities. This results in a high impact on the confidentiality, integrity, and availability of the application. |
| Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability allows OS Command Injection as root
This issue affects Iocharger firmware for AC models before version 241207101
Likelihood: Moderate – The <redacted> binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a crafted HTTP request.
Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services.
CVSS clarification: Any network connection serving the web interface is vulnerable (AV:N) and there are no additional measures to circumvent (AC:L) nor does the attack require special conditions to be present (AT:N). The attack requires authentication, but the level does not matter (PR:L), nor is user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H) and a compromised device can be used to potentially "pivot" into a network that should nopt be reachable (SC:L/SI:L/SA:H). Because this is an EV charger handing significant power, there is a potential safety impact (S:P). THe attack can be autometed (AU:Y). |
| The SIMPLE.ERP client stores superuser password in a recoverable format, allowing any authenticated SIMPLE.ERP user to escalate privileges to a database administrator.
This issue affect SIMPLE.ERP from 6.20 through 6.30. Only the 6.30 version received a patch 6.30@a03.9, which removed the vulnerability. Versions 6.20 and 6.25 remain unpatched. |
| A vulnerability classified as critical was found in IROAD Dash Cam X5 and Dash Cam X6 up to 20250308. Affected by this vulnerability is an unknown functionality of the component Device Pairing. The manipulation leads to hard-coded credentials. Access to the local network is required for this attack to succeed. The complexity of an attack is rather high. The exploitation appears to be difficult. The vendor was contacted early about this disclosure but did not respond in any way. |
| A vulnerability classified as critical has been found in IROAD X5 Mobile App up to 5.2.5 on Android. Affected is an unknown function of the component API Endpoint. The manipulation leads to hard-coded credentials. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way. |
| Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability in Iocharger firmware for AC models allows OS Command Injection as root
This issue affects all Iocharger AC EV charger models on a firmware version before 25010801.
Likelihood: Moderate – The <redacted> binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a crafted HTTP request.
Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete
files and services.
CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y). |
| A vulnerability exists in the message queueing mechanism that if
exploited can lead to the exposure of resources or functionality to
unintended actors, possibly providing attackers with sensitive information or even execute arbitrary code. |
| Weak password storage vulnerabilities exist in ASPECT if administrator credentials become compromisedThis issue affects ASPECT-Enterprise: through 3.*; NEXUS Series: through 3.*; MATRIX Series: through 3.*. |
| The authenticated SCU firmware command of the firmware for Mennekes Smart / Premium Chargingpoints can be abused for command execution because OS commands are improperly neutralized when certain fields are passed to the underlying OS. |
| An attacker could decrypt sensitive data, impersonate legitimate users
or devices, and potentially gain access to network resources for lateral
attacks. |