| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| Nozomi Networks Labs identified a CWE-319: Cleartext Transmission of Sensitive Information vulnerability in the edgserver management protocol of Advantech EKI-1242EIMS in firmware version V1.06.01 that allows a network-adjacent passive observer to intercept management traffic and recover sensitive device identity and network metadata in cleartext. |
| Nozomi Networks Labs identified a CWE-306: Missing Authentication for Critical Function vulnerability in the edgserver management protocol of Advantech EKI-1242EIMS in firmware version V1.06.01 that allows a remote unauthenticated attacker to invoke critical device-management functions, including network reconfiguration, reboot, reset, and firmware upgrade, by sending crafted requests to TCP port 5058. |
| Nozomi Networks Labs identified a CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability in the edgserver management service of Advantech EKI-1242EIMS in firmware version V1.06.01 that allows a remote unauthenticated attacker to execute arbitrary OS commands as root via crafted requests to TCP port 5058. |
| Nozomi Networks Labs identified a CWE-73: External Control of File Name or Path vulnerability in the backup-restore workflow of Advantech EKI-1242EIMS in firmware version V1.06.01 that allows a remote authenticated attacker to overwrite arbitrary files on the device filesystem by uploading a crafted backup archive through the web management interface. |
| Nozomi Networks Labs identified a CWE-94: Improper Control of Generation of Code ('Code Injection') vulnerability in the Modbus CSV import workflow of Advantech EKI-1242EIMS in firmware version V1.06.01 that allows a remote authenticated attacker to execute arbitrary Lua code on the device via a crafted imported file. |
| Nozomi Networks Labs identified a CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability in the Modbus transaction management interface of Advantech EKI-1242EIMS in firmware version V1.06.01 that allows a remote authenticated attacker to store malicious script content that executes in the browser of any administrator who later opens an affected management page. |
| Nozomi Networks Labs identified a CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability in the web management interface of Advantech EKI-1242IEIMS in firmware version V1.06.01 that allows a remote authenticated attacker to execute arbitrary OS commands as root via crafted request parameters. |
| Frappe HR is an open-source human resources management solution (HRMS). Prior to 16.7.0, an authenticated user with the HR User role can inject SQL through filters in the Salary Payments Based on Payment Mode report. In hrms/payroll/report/salary_payments_based_on_payment_mode/salary_payments_based_on_payment_mode.py, get_conditions constructs filter clauses from user-controlled values and get_data incorporates those clauses into a string-formatted SQL query, allowing extraction of arbitrary database data. This issue is fixed in 16.7.0. |
| A vulnerability was detected in Dromara mayfly-go up to 1.11.5. The impacted element is the function RunMachineScript of the file server/internal/machine/api/machine_script.go of the component Machine Script Feature. The manipulation of the argument params results in os command injection. The attack can be executed remotely. The exploit is now public and may be used. Exploitation needs no admin account. Any account holding machine:script:run plus tag access reaches arbitrary command execution on machines whose templates contain {{.param}} placeholders; the SSH exec layer (Cli.Run) also applies no input filtering to any caller. The vendor was contacted early about this disclosure but did not respond in any way. |
| Use after free in Windows Modern Execution Server allows an authorized attacker to elevate privileges locally. |
| Uncontrolled search path element in Windows Hello allows an authorized attacker to bypass a security feature locally. |
| Missing authorization in Windows Remote Access Connection Manager allows an authorized attacker to perform tampering locally. |
| Use after free in Windows Deployment Services allows an unauthorized attacker to execute code over a network. |
| Out-of-bounds read in Windows USB Hub Driver allows an unauthorized attacker to elevate privileges with a physical attack. |
| Out-of-bounds read in Windows Win32K allows an authorized attacker to disclose information locally. |
| Uninitialized resource in GPU in Google Chrome prior to 153.0.8010.36 allowed a remote attacker who had compromised the renderer process to read memory outside the sandbox via a crafted HTML page. (Chromium security severity: High) |
| Uninitialized resource in GPU in Google Chrome on on Android prior to 153.0.8010.36 allowed a remote attacker who had compromised the renderer process to read memory outside the sandbox via a crafted HTML page. (Chromium security severity: Medium) |
| Missing authentication for critical function in Windows Autopilot allows an authorized attacker to perform tampering locally. |
| In Jenkins 2.579 and earlier, LTS 2.568.2 and earlier, transient fields cannot be excluded from deserialization, allowing attackers able to submit configuration updates to specify the values of transient fields that will be deserialized, the impact depending on how those fields are used. |
| In Stapler 1839.ved17667b_a_eb_5 through 2107.v8dfcb_e8ed317 (both inclusive), except 2088.2093.vd7c3e58008a_6, included in Jenkins 2.447 through 2.579 (both inclusive), LTS 2.452.1 through 2.568.2 (both inclusive), an HTTP endpoint serving dynamically generated JavaScript resources embeds the user's cross-site request forgery (CSRF) token (crumb) as a string literal, allowing attackers with control over a page hosted on the same site as Jenkins to obtain a valid crumb for the targeted user's session and perform actions on their behalf. |