| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| NVIDIA DOCA-Host and Mellanox OFED contain a vulnerability in the VGT+ feature, where an attacker on a VM might cause escalation of privileges and denial of service on the VLAN. |
| Insecure Permissions vulnerability in e-trust Horacius 1.0, 1.1, and 1.2 allows a local attacker to escalate privileges via the password reset function. |
| NVIDIA ConnectX Firmware contains a vulnerability where an attacker may cause an improper handling of insufficient privileges issue. A successful exploit of this vulnerability may lead to denial of service, data tampering, and limited information disclosure. |
| NVIDIA ConnectX Host Firmware for the BlueField Data Processing Unit (DPU) contains a vulnerability where an attacker may cause an improper handling of insufficient privileges issue. A successful exploit of this vulnerability may lead to denial of service, data tampering, and limited information disclosure. |
| Incorrect default permissions in some Intel(R) Gaudi(R) software installers before version 1.18 may allow an authenticated user to potentially enable escalation of privilege via local access. |
| A flaw was found in the Mirror Registry. The quay-app container shipped as part of the Mirror Registry for OpenShift has write access to the `/etc/passwd`. This flaw allows a malicious actor with access to the container to modify the passwd file and elevate their privileges to the root user within that pod. |
| A security issue was discovered in Kubernetes clusters with Windows nodes where BUILTIN\Users may be able to read container logs and NT AUTHORITY\Authenticated Users may be able to modify container logs. |
| When installing Nessus to a non-default location on a Windows host, Nessus versions prior to 10.8.4 did not enforce secure permissions for sub-directories. This could allow for local privilege escalation if users had not secured the directories in the non-default installation location. - CVE-2025-24914 |
| Attackers with local access to the medical office computer can
escalate their Windows user privileges to "NT AUTHORITY\SYSTEM" by
overwriting one of two Elefant service binaries with weak permissions. The default installation directory of Elefant is "C:\Elefant1" which is
writable for all users. In addition, the Elefant installer registers two
Firebird database services which are running as “NT AUTHORITY\SYSTEM”.
Path: C:\Elefant1\Firebird_2\bin\fbserver.exe
Path: C:\Elefant1\Firebird_2\bin\fbguard.exe
Both service binaries are user writable. This means that a local
attacker can rename one of the service binaries, replace the service
executable with a new executable, and then restart the system. Once the
system has rebooted, the new service binary is executed as "NT
AUTHORITY\SYSTEM". |
| Windows permissions for ASPECT configuration toolsets are not fully secured allow-ing exposure of configuration informationThis issue affects ASPECT-Enterprise: through 3.*; NEXUS Series: through 3.*; MATRIX Series: through 3.*. |
| A remote attacker using the insecure upload functionality will be able to overwrite any Python file and get Remote Code Execution. As for the affected products/models/versions, see the reference URL. |
| Toshiba printers use Sendmail to send emails to recipients. Sendmail is used with several insecure directories. A local attacker can inject a malicious Sendmail configuration file. As for the affected products/models/versions, see the reference URL. |
| Clario through 2024-04-11 for Desktop has weak permissions for %PROGRAMDATA%\Clario and tries to load DLLs from there as SYSTEM. |
| The application Faronics WINSelect (Standard + Enterprise) saves its configuration in an encrypted file on the file system which "Everyone" has read and write access to, path to file:
C:\ProgramData\WINSelect\WINSelect.wsd
The path for the affected WINSelect Enterprise configuration file is:
C:\ProgramData\Faronics\StorageSpace\WS\WINSelect.wsd |
| Coredump binaries in Toshiba printers have incorrect permissions. A local attacker can steal confidential information. As for the affected products/models/versions, see the reference URL. |
| Incorrect default permissions in some Intel(R) Xeon(R) processor memory controller configurations when using Intel(R) SGX may allow a privileged user to potentially enable escalation of privilege via local access. |
| Insecure Permission vulnerability in Agasta Sanketlife 2.0 Pocket 12-Lead ECG Monitor FW Version 3.0 allows a local attacker to cause a denial of service via the Bluetooth Low Energy (BLE) component. |
| Incorrect execution-assigned permissions for some Edge Orchestrator software for Intel(R) Tiber™ Edge Platform may allow an authenticated user to potentially enable escalation of privilege via local access. |
| Insecure inherited permissions in the NVM Update Utility for some Intel(R) Ethernet Network Adapter E810 Series before version 4.60 may allow an authenticated user to potentially enable escalation of privilege via local access. |
| Incorrect Default Permissions for some Intel(R) RealSense™ SDK software before version 2.56.2 may allow an authenticated user to potentially enable escalation of privilege via local access. |