| D-Link DPH-400S/SE VoIP Phone v1.01 contains hardcoded provisioning variables, including PROVIS_USER_PASSWORD, which may expose sensitive user credentials. An attacker with access to the firmware image can extract these credentials using static analysis tools such as strings or xxd, potentially leading to unauthorized access to device functions or user accounts. This vulnerability exists due to insecure storage of sensitive information in the firmware binary. |
| A vulnerability, which was classified as critical, has been found in LB-LINK BL-AC3600 1.0.22. Affected by this issue is some unknown functionality of the file /etc/shadow. The manipulation with the input root:blinkadmin leads to hard-coded credentials. Local access is required to approach this attack. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way. |
| A hardcoded secret in Ivanti DSM before 2024.2 allows an authenticated attacker on an adjacent network to decrypt sensitive data including user credentials. |
| A use of hard-coded cryptographic key vulnerability in FortiSIEM version 5.2.6 may allow a remote unauthenticated attacker to obtain SSH access to the supervisor as the restricted user "tunneluser" by leveraging knowledge of the private key from another installation or a firmware image. |
| Hard-coded JWT secret allows authentication bypass in Veeam Recovery Orchestrator |
| A vulnerability was found in i-Drive i11 and i12 up to 20250227 and classified as problematic. This issue affects some unknown processing of the component APK. The manipulation leads to hard-coded credentials. It is possible to launch the attack on the physical device. It was not possible to identify the current maintainer of the product. It must be assumed that the product is end-of-life. |
| CarlinKit CPC200-CCPA Wireless Hotspot Hard-Coded Credentials Authentication Bypass Vulnerability. This vulnerability allows network-adjacent attackers to bypass authentication on affected installations of CarlinKit CPC200-CCPA devices. Authentication is not required to exploit this vulnerability.
The specific flaw exists within the configuration of the wireless hotspot. The issue results from the use of hard-coded credentials. An attacker can leverage this vulnerability to bypass authentication on the system. Was ZDI-CAN-24349. |
| Logsign Unified SecOps Platform HTTP API Hard-coded Cryptographic Key Remote Code Execution Vulnerability. This vulnerability allows network-adjacent attackers to execute arbitrary code on affected installations of Logsign Unified SecOps Platform. Authentication is not required to exploit this vulnerability.
The specific flaw exists within the HTTP API. The issue results from using a hard-coded cryptographic key. An attacker can leverage this vulnerability to execute code in the context of root. Was ZDI-CAN-24170. |
| Incorrect access control in JMBroadcast JMB0150 Firmware v1.0 allows attackers to access hardcoded administrator credentials. |
| Voltronic Power ViewPower Pro MySQL Use of Hard-coded Credentials Local Privilege Escalation Vulnerability. This vulnerability allows local attackers to escalate privileges on affected installations of Voltronic Power ViewPower Pro. An attacker must first obtain the ability to execute low-privileged code on the target system in order to exploit this vulnerability.
The specific flaw exists within the configuration of a MySQL instance. The issue results from hardcoded database credentials. An attacker can leverage this vulnerability to escalate privileges and execute arbitrary code in the context of SYSTEM. Was ZDI-CAN-22075. |
| Azure Stack HCI Elevation of Privilege Vulnerability |
| Tenda G3 v15.01.0.5(2848_755)_EN was discovered to contain a hardcoded password vulnerability in /etc_ro/shadow, which allows attackers to log in as root |
| IBM Cognos Controller 11.0.0 through 11.0.1 and IBM Controller 11.1.0 is vulnerable to exposure of Artifactory API keys. This vulnerability allows users to publish code to private packages or repositories under the name of the organization. |
| The Carlo Gavazzi
EOS-Box
stores hard-coded passwords in the PHP file of
the device. By using the hard-coded passwords, attackers can log into
the device with administrative privileges. This could allow the attacker
to have unauthorized access. |
| A vulnerability in the Out-of-Band Access Point (AP) Image Download, the Clean Air Spectral Recording, and the client debug bundles features of Cisco IOS XE Software for Wireless LAN Controllers (WLCs) could allow an unauthenticated, remote attacker to upload arbitrary files to an affected system.
This vulnerability is due to the presence of a hard-coded JSON Web Token (JWT) on an affected system. An attacker could exploit this vulnerability by sending crafted HTTPS requests to the AP file upload interface. A successful exploit could allow the attacker to upload files, perform path traversal, and execute arbitrary commands with root privileges. |
| Netwrix Directory Manager (formerly Imanami GroupID) through v.10.0.7784.0 has a hard-coded password. |
| D-LINK Go-RT-AC750 GORTAC750_A1_FW_v101b03 has a hardcoded password for the Alphanetworks account, which allows remote attackers to obtain root access via a telnet session. |
| TOTOLINK A8000RU v7.1cu.643_B20200521 was discovered to contain a hardcoded password for root stored in /etc/shadow. |
| It is possible to download the configuration backup without authorization and decrypt included passwords using hardcoded static key. |
| Root user password is hardcoded into the device and cannot be changed in the user interface.
|