In AutomationDirect C-MORE EA9 HMI,
credentials used by the platform are stored as plain text on the device.
|
| Clash Verge Rev thru 2.2.3 (fixed in 2.3.0) forces the installation of system services(clash-verge-service) by default and exposes key functions through the unauthorized HTTP API `/start_clash`, allowing local users to submit arbitrary bin_path parameters and pass them directly to the service process for execution, resulting in local privilege escalation. |
| calamares-nixos-extensions provides Calamares branding and modules for NixOS, a distribution of GNU/Linux. Users who installed NixOS through the graphical installer who used manual disk partitioning to create a setup where the system was booted via legacy BIOS rather than UEFI; some disk partitions are encrypted; but the partitions containing either `/` or `/boot` are unencrypted; have their LUKS disk encryption key file in plain text either in `/crypto_keyfile.bin`, or in a CPIO archive attached to their NixOS initrd. `nixos-install` is not affected, nor are UEFI installations, nor was the default automatic partitioning configuration on legacy BIOS systems. The problem has been fixed in calamares-nixos-extensions 0.3.17, which was included in NixOS. The current installer images for the NixOS 24.05 and unstable (24.11) channels are unaffected. The fix reached 24.05 at 2024-08-13 20:06:59 UTC, and unstable at 2024-08-15 09:00:20 UTC. Installer images downloaded before those times may be vulnerable. The best solution for affected users is probably to back up their data and do a complete reinstallation. However, the mitigation procedure in GHSA-3rvf-24q2-24ww should work solely for the case where `/` is encrypted but `/boot` is not. If `/` is unencrypted, then the `/crypto_keyfile.bin` file will need to be deleted in addition to the remediation steps in the previous advisory. This issue is a partial regression of CVE-2023-36476 / GHSA-3rvf-24q2-24ww, which was more severe as it applied to the default configuration on BIOS systems. |
| A privilege escalation vulnerability may enable a service account to elevate its privileges.
The sudo rules configured for a local service account were excessively permissive, potentially allowing administrative access if a malicious actor could execute arbitrary commands as that account.
It is important to note that no such vector has been identified in this instance. |
| A vulnerability has been found in FAST/TOOLS and CI Server. The affected products have built-in accounts with no passwords set. Therefore, if the product is operated without a password set by default, an attacker can break into the affected product.
The affected products and versions are as follows:
FAST/TOOLS (Packages: RVSVRN, UNSVRN, HMIWEB, FTEES, HMIMOB) R9.01 to R10.04
CI Server R1.01.00 to R1.03.00 |
| The Toshiba printers do not implement privileges separation. As for the affected products/models/versions, see the reference URL. |
| Screen 5.0.0 when it runs with setuid-root privileges does not drop privileges while operating on a user supplied path. This allows unprivileged users to create files in arbitrary locations with `root` ownership, the invoking user's (real) group ownership and file mode 0644. All data written to the Screen PTY will be logged into this file, allowing to escalate to root privileges |
| A vulnerability in the Incoming Goods Suite allows a user with unprivileged access to the underlying system (e.g. local or via SSH) a privilege escalation to the administrative level due to the usage of component vendor Docker images running with root permissions. Exploiting this misconfiguration leads to the fact that an attacker can gain administrative control. over the whole system. |
| NetSupport Manager < 14.12.0001 relies on a shared Gateway Key for authentication between Manager/Control, Client, and Connectivity Server components. The key is stored using a reversible encoding scheme. An attacker who obtains access to a deployed client configuration file can decode the stored value to recover the plaintext Gateway Key. Possession of the Gateway Key allows unauthorized access to NetSupport Manager connectivity services and enables remote control of systems managed through the same key. |
| An Execution with Unnecessary Privileges vulnerability has been identified in Moxa’s network security appliances and routers. A critical authorization flaw in the API allows an authenticated, low-privileged user to create a new administrator account, including accounts with usernames identical to existing users. In certain scenarios, this vulnerability could allow an attacker to gain full administrative control over the affected device, leading to potential account impersonation. While successful exploitation can severely impact the confidentiality, integrity, and availability of the affected device itself, there is no loss of confidentiality or integrity within any subsequent systems. |
| Command injection in the <redacted> parameter of a <redacted>.exe request leads to remote code execution as the root user.
This issue affects Iocharger firmware for AC models before version 24120701.
Likelihood: Moderate – This action is not a common place for command injection vulnerabilities to occur. Thus, an attacker will likely only be able to find this vulnerability by reverse-engineering the firmware or trying it on all <redacted> fields. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a payload.
Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services.
CVSS clarification. The attack can be executed over any network connection the station is listening to and serves the web interface (AV:N), and there are no additional security measure sin place that need to be circumvented (AC:L), the attack does not rely on preconditions (AT:N). The attack does require authentication, but the level of authentication is irrelevant (PR:L), it does not require user interaction (UI:N). If is a full system compromise, potentially fully compromising confidentiality, integrity and availability of the devicer (VC:H/VI:H/VA:H). A compromised charger can be used to "pivot" onto networks that should otherwise be closed, cause a low confidentiality and interity impact on subsequent systems. (SC:L/SI:L/SA:H). Because this device is an EV charger handing significant amounts of power, we suspect this vulnerability can have a safety impact (S:P). The attack can be automated (AU:Y). |
| A vulnerability in the web API of HPE Aruba Networking EdgeConnect SD-WAN Gateways could allow an authenticated remote attacker to terminate arbitrary running processes. Successful exploitation could allow an attacker to disrupt system operations, potentially resulting in an unstable system state. |
| A vulnerability has been identified in SIMATIC BATCH V9.1 (All versions), SIMATIC Information Server 2020 (All versions < V2020 SP2 Update 5), SIMATIC Information Server 2022 (All versions < V2022 SP1 Update 2), SIMATIC PCS 7 V9.1 (All versions < V9.1 SP2 UC06), SIMATIC Process Historian 2020 (All versions < V2020 SP2 Update 5), SIMATIC Process Historian 2022 (All versions < V2022 SP1 Update 2), SIMATIC WinCC Runtime Professional V18 (All versions < V18 Update 5), SIMATIC WinCC Runtime Professional V19 (All versions < V19 Update 3), SIMATIC WinCC V7.4 (All versions), SIMATIC WinCC V7.5 (All versions < V7.5 SP2 Update 18), SIMATIC WinCC V8.0 (All versions < V8.0 Update 5). The affected products run their DB server with elevated privileges which could allow an authenticated attacker to execute arbitrary OS commands with administrative privileges. |
| The access control in CemiPark software stores integration (e.g. FTP or SIP) credentials in plain-text. An attacker who gained unauthorized access to the device can retrieve clear text passwords used by the system.This issue affects CemiPark software: 4.5, 4.7, 5.03 and potentially others. The vendor refused to provide the specific range of affected products.
|
| Incorrect Access Control vulnerability in ZLMediaKit versions 1.0 through 8.0, allows remote attackers to escalate privileges and obtain sensitive information. The application system enables the http API interface by default and uses the secret parameter method to authenticate the http restful api interface, but the secret is hardcoded by default. |
| WF2220 exposes endpoint /cgi-bin-igd/netcore_get.cgi that returns configuration of the device to unauthorized users. Returned configuration includes cleartext password.
The vendor was contacted early about this disclosure but did not respond in any way. |
| Bosscomm IF740 Firmware versions:11001.7078 & v11001.0000 and System versions: 6.25 & 6.00 were discovered to store passwords in cleartext. |
| The authenticated time setting capability of the firmware for Mennekes Smart / Premium Chargingpoints can be abused for command execution because OS command are improperly neutralized when certain fields are passed to the underlying OS. |
| Westermo EDW-100 devices through 2024-05-03 allow an unauthenticated user to download a configuration file containing a cleartext password. NOTE: this is a serial-to-Ethernet converter that should not be placed at the edge of the network. |
| A vulnerability exists in the VideONet product included in the listed System 800xA versions, where VideONet is used.
An attacker who successfully exploited the vulnerability could, in the worst case scenario, stop or manipulate the video feed.
This issue affects System 800xA: 5.1.X; System 800xA: 6.0.3.X; System 800xA: 6.1.1.X; System 800xA: 6.2.X. |