| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| A vulnerability has been identified in LOGO! 12/24RCE (6ED1052-1MD08-0BA2) (All versions < V1.84.05), LOGO! 12/24RCEo (6ED1052-2MD08-0BA2) (All versions < V1.84.05), LOGO! 230RCE (6ED1052-1FB08-0BA2) (All versions < V1.84.05), LOGO! 230RCEo (6ED1052-2FB08-0BA2) (All versions < V1.84.05), LOGO! 24CE (6ED1052-1CC08-0BA2) (All versions < V1.84.05), LOGO! 24CEo (6ED1052-2CC08-0BA2) (All versions < V1.84.05), LOGO! 24RCE (6ED1052-1HB08-0BA2) (All versions < V1.84.05), LOGO! 24RCEo (6ED1052-2HB08-0BA2) (All versions < V1.84.05), SIPLUS LOGO! 12/24RCE (6AG1052-1MD08-7BA2) (All versions < V1.84.05), SIPLUS LOGO! 12/24RCEo (6AG1052-2MD08-7BA2) (All versions < V1.84.05), SIPLUS LOGO! 230RCE (6AG1052-1FB08-7BA2) (All versions < V1.84.05), SIPLUS LOGO! 230RCEo (6AG1052-2FB08-7BA2) (All versions < V1.84.05), SIPLUS LOGO! 24CE (6AG1052-1CC08-7BA2) (All versions < V1.84.05), SIPLUS LOGO! 24CEo (6AG1052-2CC08-7BA2) (All versions < V1.84.05), SIPLUS LOGO! 24RCE (6AG1052-1HB08-7BA2) (All versions < V1.84.05), SIPLUS LOGO! 24RCEo (6AG1052-2HB08-7BA2) (All versions < V1.84.05). Affected devices do not conduct certain validations when interacting with them. This could allow an unauthenticated remote attacker to change time of the device, which means the device could behave differently. |
| A vulnerability has been identified in LOGO! 12/24RCE (6ED1052-1MD08-0BA2) (All versions < V1.84.05), LOGO! 12/24RCEo (6ED1052-2MD08-0BA2) (All versions < V1.84.05), LOGO! 230RCE (6ED1052-1FB08-0BA2) (All versions < V1.84.05), LOGO! 230RCEo (6ED1052-2FB08-0BA2) (All versions < V1.84.05), LOGO! 24CE (6ED1052-1CC08-0BA2) (All versions < V1.84.05), LOGO! 24CEo (6ED1052-2CC08-0BA2) (All versions < V1.84.05), LOGO! 24RCE (6ED1052-1HB08-0BA2) (All versions < V1.84.05), LOGO! 24RCEo (6ED1052-2HB08-0BA2) (All versions < V1.84.05), SIPLUS LOGO! 12/24RCE (6AG1052-1MD08-7BA2) (All versions < V1.84.05), SIPLUS LOGO! 12/24RCEo (6AG1052-2MD08-7BA2) (All versions < V1.84.05), SIPLUS LOGO! 230RCE (6AG1052-1FB08-7BA2) (All versions < V1.84.05), SIPLUS LOGO! 230RCEo (6AG1052-2FB08-7BA2) (All versions < V1.84.05), SIPLUS LOGO! 24CE (6AG1052-1CC08-7BA2) (All versions < V1.84.05), SIPLUS LOGO! 24CEo (6AG1052-2CC08-7BA2) (All versions < V1.84.05), SIPLUS LOGO! 24RCE (6AG1052-1HB08-7BA2) (All versions < V1.84.05), SIPLUS LOGO! 24RCEo (6AG1052-2HB08-7BA2) (All versions < V1.84.05). Affected devices do not conduct certain validations when interacting with them. This could allow an unauthenticated remote attacker to manipulate the devices IP address, which means the device would not be reachable. |
| A vulnerability has been identified in LOGO! 12/24RCE (6ED1052-1MD08-0BA2) (All versions < V1.84.05), LOGO! 12/24RCEo (6ED1052-2MD08-0BA2) (All versions < V1.84.05), LOGO! 230RCE (6ED1052-1FB08-0BA2) (All versions < V1.84.05), LOGO! 230RCEo (6ED1052-2FB08-0BA2) (All versions < V1.84.05), LOGO! 24CE (6ED1052-1CC08-0BA2) (All versions < V1.84.05), LOGO! 24CEo (6ED1052-2CC08-0BA2) (All versions < V1.84.05), LOGO! 24RCE (6ED1052-1HB08-0BA2) (All versions < V1.84.05), LOGO! 24RCEo (6ED1052-2HB08-0BA2) (All versions < V1.84.05), SIPLUS LOGO! 12/24RCE (6AG1052-1MD08-7BA2) (All versions < V1.84.05), SIPLUS LOGO! 12/24RCEo (6AG1052-2MD08-7BA2) (All versions < V1.84.05), SIPLUS LOGO! 230RCE (6AG1052-1FB08-7BA2) (All versions < V1.84.05), SIPLUS LOGO! 230RCEo (6AG1052-2FB08-7BA2) (All versions < V1.84.05), SIPLUS LOGO! 24CE (6AG1052-1CC08-7BA2) (All versions < V1.84.05), SIPLUS LOGO! 24CEo (6AG1052-2CC08-7BA2) (All versions < V1.84.05), SIPLUS LOGO! 24RCE (6AG1052-1HB08-7BA2) (All versions < V1.84.05), SIPLUS LOGO! 24RCEo (6AG1052-2HB08-7BA2) (All versions < V1.84.05). Affected devices do not properly validate the structure of TCP packets in several methods. This could allow an attacker to cause buffer overflows, get control over the instruction counter and run custom code. |
| A vulnerability has been identified in SIMATIC S7-PLCSIM V17 (All versions), SIMATIC S7-PLCSIM V18 (All versions), SIMATIC STEP 7 Safety V17 (All versions < V17 Update 9), SIMATIC STEP 7 Safety V18 (All versions < V18 Update 6), SIMATIC STEP 7 Safety V19 (All versions < V19 Update 4), SIMATIC STEP 7 V17 (All versions < V17 Update 9), SIMATIC STEP 7 V18 (All versions < V18 Update 6), SIMATIC STEP 7 V19 (All versions < V19 Update 4), SIMATIC WinCC Unified PC Runtime V18 (All versions), SIMATIC WinCC Unified PC Runtime V19 (All versions < V19 Update 4), SIMATIC WinCC Unified V17 (All versions < V17 Update 9), SIMATIC WinCC Unified V18 (All versions < V18 Update 6), SIMATIC WinCC Unified V19 (All versions < V19 Update 4), SIMATIC WinCC V17 (All versions < V17 Update 9), SIMATIC WinCC V18 (All versions < V18 Update 6), SIMATIC WinCC V19 (All versions < V19 Update 4), SIMOCODE ES V17 (All versions), SIMOCODE ES V18 (All versions), SIMOCODE ES V19 (All versions), SIMOTION SCOUT TIA V5.4 (All versions), SIMOTION SCOUT TIA V5.5 (All versions), SIMOTION SCOUT TIA V5.6 (All versions < V5.6 SP1 HF7), SINAMICS Startdrive V17 (All versions), SINAMICS Startdrive V18 (All versions), SINAMICS Startdrive V19 (All versions), SIRIUS Safety ES V17 (TIA Portal) (All versions), SIRIUS Safety ES V18 (TIA Portal) (All versions), SIRIUS Safety ES V19 (TIA Portal) (All versions), SIRIUS Soft Starter ES V17 (TIA Portal) (All versions), SIRIUS Soft Starter ES V18 (TIA Portal) (All versions), SIRIUS Soft Starter ES V19 (TIA Portal) (All versions), TIA Portal Cloud V17 (All versions), TIA Portal Cloud V18 (All versions), TIA Portal Cloud V19 (All versions < V5.2.1.1). The affected devices do not properly sanitize user-controllable input when parsing user settings. This could allow an attacker to locally execute arbitrary commands in the host operating system with the privileges of the user. |
| A flaw has been found in Wavlink WL-WN592AX6 250422. This issue affects the function system of the component wmapd Daemon. Executing a manipulation can lead to os command injection. It is possible to launch the attack remotely. The exploit has been published and may be used. The vendor was contacted early about this disclosure. |
| A flaw was found in the Client-Initiated Backchannel Authentication CIBA implementation within the keycloak-services component of Keycloak. This component handles advanced authentication flows where a client initiates a login on behalf of a user. The issue occurs because Keycloak fails to verify that a client is authorized to use the CIBA flow, allowing public clients to bypass security requirements. An attacker could use this flaw to trick a user into approving a login request, eventually gaining full access to the users account without needing a client secret. |
| Several administrative actions do not sufficiently validate whether a request was intentionally initiated by the authenticated user. In particular, the DBUpdateLogCleanUp action can be triggered through a GET request without validating a ChallengeToken. An unauthenticated remote attacker can therefore cause the browser of an authenticated administrator to execute the cleanup action by embedding a crafted request in a malicious web page. Successful exploitation can delete existing DBUpdate log entries. This may reduce the availability of diagnostic and historical information used for troubleshooting and auditing. The impact is limited to DBUpdate log entries that exist at the time the forged request is processed.
Additional administrative endpoints were identified that do not validate a ChallengeToken. Some of these endpoints can trigger administrative actions such as deploying or synchronizing already existing configuration. They do not allow an attacker to introduce arbitrary new configuration through the CSRF request itself.
Export and read-only endpoints were also identified without ChallengeToken validation. While these endpoints may be triggered through a forged cross-site request, the response content remains subject to the browser's same-origin restrictions and is not automatically exposed to the attacker. Therefore, no direct confidentiality impact has been demonstrated for these endpoints.
This issue affects OTRS:
* 7.0.X
* 8.0.X
* 2023.X
* 2024.X
* 2025.X
* 2026.X before 2026.7.X
Please note that ((OTRS)) Community Edition 6.x and before are vulnerable. Products based on the ((OTRS)) Community Edition also very likely to be affected |
| In Thelia v2.6.0, the document upload endpoint properly blocks the upload of executable file types, but the document update endpoint does not perform the same validation. An attacker with administrative Thelia permissions can exploit this vulnerability to upload arbitrary executable files, such as malicious PHP scripts, to achieve remote code execution on the underlying server. |
| In Thelia v2.6.0, the store banner upload feature performs insufficient filetype validation that relies exclusively on client‑supplied MIME types. An attacker with administrative access can upload a PHP file disguised as an image to bypass validation and achieve remote code execution on the underlying server. |
| In Thelia v2.6.0, both the administrative login and forgotten password endpoints return different responses for invalid usernames and incorrect passwords, allowing unauthenticated attackers to enumerate valid administrator accounts. Because the endpoint also lacks rate limiting or other protections against repeated authentication attempts, username enumeration can be performed efficiently at scale. |
| Path traversal in Smart Switch prior to version 3.7.73 allows physical attackers to access files with Smart Switch privilege. |
| User-controlled values are not sufficiently neutralized when included in CSV exports. Values originating from user input, including data submitted by authenticated users or received through external communication channels such as email, may be stored in fields that are later included in CSV exports. An attacker can therefore inject values beginning with spreadsheet formula characters such as =, +, -, or @. An attacker does not necessarily require an authenticated account if the affected field can be populated through an external input channel such as incoming email.
When an affected CSV file is opened in spreadsheet software, the application may interpret these values as formulas instead of plain text. Depending on the spreadsheet application and its security configuration, a malicious formula may cause unintended actions, disclose information, or invoke external functionality. Exploitation may require the user opening the exported CSV file to confirm one or more security warning dialogs. The vulnerability does not execute code on the OTRS server; any additional impact occurs in the spreadsheet application used to process the exported file.
This issue affects OTRS:
* 7.0.X
* 8.0.X
* 2023.X
* 2024.X
* 2025.X
* 2026.X before 2026.7.X
Please note that ((OTRS)) Community Edition 6.x and before are vulnerable. Products based on the ((OTRS)) Community Edition also very likely to be affected |
| Missing Authorization vulnerability in Arraytics Booktics booktics allows Exploiting Incorrectly Configured Access Control Security Levels.This issue affects Booktics: from n/a through 1.0.28. |
| This CVE ID has been rejected or withdrawn by its CVE Numbering Authority. False-positive. |
| Progress MarkLogic Server 12.x releases before 12.1.0 and 11.x releases before 11.3.7 contain a cross-site scripting vulnerability that could allow a remote attacker to execute script in the context of an authenticated user's browser session, which could result in unauthorized actions or disclosure of information accessible to that user. |
| Progress MarkLogic Server 12.x releases before 12.1.0 contain an out-of-bounds read vulnerability in certain query-processing functionality. A remote authenticated attacker could exploit this vulnerability to cause server instability or disclose limited information from process memory. |
| Progress MarkLogic Server 12.x releases before 12.1.0 and 11.x releases before 11.3.7 enable XML external entity processing by default in multiple server paths, which could allow crafted XML to cause server-side requests or disclosure of local files. |
| IBM Power Systems Firmware FW1110.00 through FW1110.31, FW1120.00 through FW1120.01, and FW1060.00 through FW1060.81 could allow a remote authenticated attacker to cause a denial of service by exhausting connection resources due to improper resource management. |
| Missing Authorization vulnerability in MultiVendorX MultiVendorX dc-woocommerce-multi-vendor allows Exploiting Incorrectly Configured Access Control Security Levels.This issue affects MultiVendorX: from n/a through 5.0.20. |
| Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability in Inisev Social Share Icons & Social Share Buttons ultimate-social-media-plus allows Reflected XSS.This issue affects Social Share Icons & Social Share Buttons: from n/a through 3.7.5. |