| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| In the Linux kernel, the following vulnerability has been resolved:
scsi: pm80xx: Avoid leaking tags when processing OPC_INB_SET_CONTROLLER_CONFIG command
Tags allocated for OPC_INB_SET_CONTROLLER_CONFIG command need to be freed
when we receive the response. |
| A vulnerability was identified in youlaitech youlai-mall 1.0.0/2.0.0. The impacted element is the function orderService.payOrder of the file mall-oms/oms-boot/src/main/java/com/youlai/mall/oms/controller/app/OrderController.java of the component Order Payment Handler. The manipulation leads to improper access controls. The attack can be initiated remotely. The attack is considered to have high complexity. The exploitability is regarded as difficult. The exploit is publicly available and might be used. The vendor was contacted early about this disclosure but did not respond in any way. |
| Tiny File Manager version 2.4.8 allows an unauthenticated remote attacker to access the application's internal files. This is possible because the application is vulnerable to broken access control.
|
| A privileged Vault operator with write permissions to the root namespace’s identity endpoint could escalate their own or another user’s privileges to Vault’s root policy. Fixed in Vault Community Edition 1.18.0 and Vault Enterprise 1.18.0, 1.17.7, 1.16.11, and 1.15.16. |
| A maliciously crafted STP file in ASMKERN228A.dll when parsed through Autodesk applications can be used to dereference an untrusted pointer. This vulnerability, along with other vulnerabilities, could lead to code execution in the current process. |
| Windows MSHTML Platform Spoofing Vulnerability |
| A vulnerability has been found in JeecgBoot up to 3.9.0. The affected element is the function getDeptRoleByUserId of the file /sys/sysDepartRole/getDeptRoleByUserId. Such manipulation of the argument departId leads to information disclosure. The vendor was contacted early about this disclosure but did not respond in any way. |
| Teltonika TRB1-series devices with firmware before TRB1_R_00.07.05.2 allow attackers to exploit a firmware vulnerability via Ethernet LAN or USB. |
| SolarEdge SE3680H has unauthenticated disclosure of sensitive information during the bootloader loop. While the device repeatedly initializes and waits for boot instructions, the bootloader emits diagnostic output this behavior can leak operating system information. |
| In the Linux kernel, the following vulnerability has been resolved:
regulator: core: fix use_count leakage when handling boot-on
I found a use_count leakage towards supply regulator of rdev with
boot-on option.
┌───────────────────┐ ┌───────────────────┐
│ regulator_dev A │ │ regulator_dev B │
│ (boot-on) │ │ (boot-on) │
│ use_count=0 │◀──supply──│ use_count=1 │
│ │ │ │
└───────────────────┘ └───────────────────┘
In case of rdev(A) configured with `regulator-boot-on', the use_count
of supplying regulator(B) will increment inside
regulator_enable(rdev->supply).
Thus, B will acts like always-on, and further balanced
regulator_enable/disable cannot actually disable it anymore.
However, B was also configured with `regulator-boot-on', we wish it
could be disabled afterwards. |
| In the Linux kernel, the following vulnerability has been resolved:
ARM: OMAP2+: pdata-quirks: Fix refcount leak bug
In pdata_quirks_init_clocks(), the loop contains
of_find_node_by_name() but without corresponding of_node_put(). |
| In the Linux kernel, the following vulnerability has been resolved:
ARM: OMAP2+: display: Fix refcount leak bug
In omapdss_init_fbdev(), of_find_node_by_name() will return a node
pointer with refcount incremented. We should use of_node_put() when
it is not used anymore. |
| In the Linux kernel, the following vulnerability has been resolved:
usb: renesas: Fix refcount leak bug
In usbhs_rza1_hardware_init(), of_find_node_by_name() will return
a node pointer with refcount incremented. We should use of_node_put()
when it is not used anymore. |
| In the Linux kernel, the following vulnerability has been resolved:
xtensa: xtfpga: Fix refcount leak bug in setup
In machine_setup(), of_find_compatible_node() will return a node
pointer with refcount incremented. We should use of_node_put() when
it is not used anymore. |
| In the Linux kernel, the following vulnerability has been resolved:
cpufreq: pmac32-cpufreq: Fix refcount leak bug
In pmac_cpufreq_init_MacRISC3(), we need to add corresponding
of_node_put() for the three node pointers whose refcount have
been incremented by of_find_node_by_name(). |
| In the Linux kernel, the following vulnerability has been resolved:
net: tipc: fix possible refcount leak in tipc_sk_create()
Free sk in case tipc_sk_insert() fails. |
| In the Linux kernel, the following vulnerability has been resolved:
ARM: versatile: Add missing of_node_put in dcscb_init
The device_node pointer is returned by of_find_compatible_node
with refcount incremented. We should use of_node_put() to avoid
the refcount leak. |
| In the Linux kernel, the following vulnerability has been resolved:
ARM: hisi: Add missing of_node_put after of_find_compatible_node
of_find_compatible_node will increment the refcount of the returned
device_node. Calling of_node_put() to avoid the refcount leak |
| In the Linux kernel, the following vulnerability has been resolved:
powerpc/xics: fix refcount leak in icp_opal_init()
The of_find_compatible_node() function returns a node pointer with
refcount incremented, use of_node_put() on it when done. |
| In the Linux kernel, the following vulnerability has been resolved:
mips: cpc: Fix refcount leak in mips_cpc_default_phys_base
Add the missing of_node_put() to release the refcount incremented
by of_find_compatible_node(). |