Search Results (3497 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2025-40671 2026-04-15 N/A
SQL injection vulnerability in AES Multimedia's Gestnet v1.07. This vulnerability allows an attacker to retrieve, create, update and delete databases via the ‘fk_remoto_central’ parameter on the ‘/webservices/articles.php’ endpoint.
CVE-2013-10047 3 Microsoft, Miniweb2, Miniweb Http Server Project 3 Windows, Miniweb, Miniweb Http Server 2026-04-15 N/A
An unrestricted file upload vulnerability exists in MiniWeb HTTP Server <= Build 300 that allows unauthenticated remote attackers to upload arbitrary files to the server’s filesystem. By abusing the upload handler and crafting a traversal path, an attacker can place a malicious .exe in system32, followed by a .mof file in the WMI directory. This triggers execution of the payload with SYSTEM privileges via the Windows Management Instrumentation service. The exploit is only viable on Windows versions prior to Vista.
CVE-2013-10049 2026-04-15 N/A
An OS command injection vulnerability exists in multiple Raidsonic NAS devices—specifically tested on IB-NAS5220 and IB-NAS4220—via the unauthenticated timeHandler.cgi endpoint exposed through the web interface. The CGI script fails to properly sanitize user-supplied input in the timeZone parameter of a POST request, allowing remote attackers to inject arbitrary shell commands.
CVE-2024-43648 2026-04-15 8.8 High
Command injection in the <redacted> parameter of a <redacted>.exe request leads to remote code execution as the root user. This issue affects Iocharger firmware for AC models before version 24120701. Likelihood: Moderate – This action is not a common place for command injection vulnerabilities to occur. Thus, an attacker will likely only be able to find this vulnerability by reverse-engineering the firmware or trying it on all <redacted> fields. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a payload. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services. CVSS clarification. The attack can be executed over any network connection the station is listening to and serves the web interface (AV:N), and there are no additional security measure sin place that need to be circumvented (AC:L), the attack does not rely on preconditions (AT:N). The attack does require authentication, but the level of authentication is irrelevant (PR:L), it does not require user interaction (UI:N). If is a full system compromise, potentially fully compromising confidentiality, integrity and availability of the devicer (VC:H/VI:H/VA:H).  A compromised charger can be used to "pivot" onto networks that should otherwise be closed, cause a low confidentiality and interity impact on subsequent systems. (SC:L/SI:L/SA:H). Because this device is an EV charger handing significant amounts of power, we suspect this vulnerability can have a safety impact (S:P). The attack can be automated (AU:Y).
CVE-2024-43650 2026-04-15 N/A
Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability in Iocharger firmware for AC models allows OS Command Injection as root This issue affects  firmware versions before 24120701. Likelihood: Moderate – The <redacted> binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a crafted HTTP request. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services. CVSS clarification: The attack can be executed over any network connection serving the web interface (AV:N). There are no additional measures that need to be circumvented (AC:L) or attack preconditions (AT:N). THe attack is privileged, but the level does not matter (PR:L) and does not require user interaction (UI:N). Attack leads to full system compromised (VC:H/VI:H/VA:H) and compromised devices can be used to "pivot" to other networks that should be unreachable (SC:L/SI:L/SA:H). Because this an EV charger using high power, there is a potential safety impact (S:P). The attack can be automated (AU:Y).
CVE-2024-43651 2026-04-15 N/A
Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability allows OS Command Injection as root This issue affects Iocharger firmware for AC models before version 241207101 Likelihood: Moderate – The <redacted> binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a crafted HTTP request. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services. CVSS clarification: Any network connection serving the web interface is vulnerable (AV:N) and there are no additional measures to circumvent (AC:L) nor does the attack require special conditions to be present (AT:N). The attack requires authentication, but the level does not matter (PR:L), nor is user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H) and a compromised device can be used to potentially "pivot" into a network that should nopt be reachable (SC:L/SI:L/SA:H). Because this is an EV charger handing significant power, there is a potential safety impact (S:P). THe attack can be autometed (AU:Y).
CVE-2024-43652 2026-04-15 8.8 High
Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability allows OS Command Injection as root This issue affects Iocharger firmware for AC model chargers before version 24120701 Likelihood: Moderate – The <redacted> binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a crafted HTTP request. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services.
CVE-2024-43653 2026-04-15 8.8 High
Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability  allows OS Command Injection as root This issue affects Iocharger firmware for AC model chargers before version 24120701. Likelihood: Moderate – The <redacted> binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a crafted HTTP request. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services. CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y).
CVE-2024-43654 2026-04-15 8.8 High
Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability in Iocharger firmware for AC models allows OS Command Injection as root This issue affects all Iocharger AC EV charger models on a firmware version before 25010801. Likelihood: Moderate – The <redacted> binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a crafted HTTP request. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services. CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y).
CVE-2024-43655 2026-04-15 N/A
Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability allows OS Command Injection as root This issue affects Iocharger firmware for AC model chargers before version 24120701. Likelihood: Moderate – The attacker will first need to find the name of the script, and needs a (low privilege) account to gain access to the script, or convince a user with such access to execute a request to it. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and deletefiles and services. CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y).
CVE-2021-47900 1 Gilacms 1 Gila Cms 2026-04-15 9.8 Critical
Gila CMS versions prior to 2.0.0 contain a remote code execution vulnerability that allows unauthenticated attackers to execute arbitrary system commands through manipulated HTTP headers. Attackers can inject PHP code in the User-Agent header with shell_exec() to run system commands by sending crafted requests to the admin endpoint.
CVE-2025-20059 2026-04-15 9.1 Critical
Relative Path Traversal vulnerability in Ping Identity PingAM Java Policy Agent allows Parameter Injection.This issue affects PingAM Java Policy Agent: through 5.10.3, through 2023.11.1, through 2024.9.
CVE-2025-11900 1 Hgiga 1 Isherlock 2026-04-15 9.8 Critical
The iSherlock developed by HGiga has an OS Command Injection vulnerability, allowing unauthenticated remote attackers to inject arbitrary OS commands and execute them on the server.
CVE-2024-8525 1 Automatedlogic 1 Webctrl 2026-04-15 N/A
An unrestricted upload of file with dangerous type in Automated Logic WebCTRL 7.0 could allow an unauthenticated user to perform remote command execution via a crafted HTTP POST request which could lead to uploading a malicious file.
CVE-2025-0129 2026-04-15 N/A
An improper exception check in Palo Alto Networks Prisma Access Browser allows a low privileged user to prevent Prisma Access Browser from applying it's Policy Rules. This enables the user to use Prisma Access Browser without any restrictions.
CVE-2025-64119 1 Nuvation Energy 1 Battery Management System 2026-04-15 N/A
A vulnerability in Nuvation Battery Management System allows Authentication Bypass.This issue affects Battery Management System: through 2.3.9.
CVE-2024-9478 1 Upkeeper Solutions 1 Upkeeper Instant Privlege Access 2026-04-15 N/A
Improper Privilege Management vulnerability in upKeeper Solutions upKeeper Instant Privilege Access allows Privilege Escalation.This issue affects upKeeper Instant Privilege Access: before 1.2.
CVE-2025-34100 2026-04-15 N/A
An unrestricted file upload vulnerability exists in BuilderEngine 3.5.0 via the integration of the elFinder 2.0 file manager and its use of the jQuery File Upload plugin. The plugin fails to properly validate or restrict file types or locations during upload operations, allowing an attacker to upload a malicious .php file and subsequently execute arbitrary PHP code on the server under the context of the web server process. While the root vulnerability lies within the jQuery File Upload component, BuilderEngine’s improper integration and lack of access controls expose this functionality to unauthenticated users, resulting in full remote code execution.
CVE-2012-10038 2026-04-15 N/A
Auxilium RateMyPet contains an unauthenticated arbitrary file upload vulnerability in upload_banners.php. The banner upload feature fails to validate file types or enforce authentication, allowing remote attackers to upload malicious PHP files. These files are stored in a web-accessible /banners/ directory and can be executed directly, resulting in remote code execution.
CVE-2012-10037 2026-04-15 N/A
PhpTax version 0.8 contains a remote code execution vulnerability in drawimage.php. The pfilez GET parameter is unsafely passed to the exec() function without sanitization. A remote attacker can inject arbitrary shell commands, leading to code execution under the web server's context. No authentication is required.