| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| The Ultimate Before After Image Slider & Gallery WordPress plugin before 4.7.1 does not escape the value of the BEAF Slider widget's shortcode field before outputting it on the front end (the value is passed through do_shortcode, which echoes non-shortcode content verbatim), allowing users with administrator-level access to store a script that executes in the browser of any visitor who loads a page displaying the widget. |
| Eclipse Grizzly in versions before 5.0.2, cannot properly parse the trailer section in malformed trailer header's line, which can be leveraged to perform HTTP request smuggling. Grizzly 5.0.1 supports system properties that enable the behavior that fixes the vulnerability - set org.glassfish.grizzly.http.STRICT_HEADER_NAME_VALIDATION_RFC_9110 and org.glassfish.grizzly.http.STRICT_HEADER_VALUE_VALIDATION_RFC_9110 system properties to "true". |
| In Eclipse Jetty, a first HTTP/1.1 request with trailers causes the server to retain the trailers in subsequent requests performed over the same connection.
Subsequent request that do not have trailers report the trailers of the first request.
Subsequent request that do have trailers report the union of trailers of the first request and the current request. |
| For requests that have a body, but reading the body may end up in reading 0 bytes, there is a buffer leak.
This is particularly the case for 100-Continue, but any request where the network is slow can leak. |
| A vulnerability has been identified in COMOS V10.4.5 (All versions < V10.4.5.0.2), COMOS V10.6 (All versions < V10.6.1), Designcenter NX (All versions < V2512.7000), Simcenter 3D (All versions < V2512.7000), Simcenter Femap V2506 (All versions < V2506.0003), Simcenter Femap V2512 (All versions < V2512.0002), Simcenter Nastran (All versions < V2606), Simcenter STAR-CCM+ (All versions < V2606), Solid Edge SE2025 (All versions < V225.0 Update 13), Solid Edge SE2026 (All versions < V226.0 Update 04), Teamcenter Visualization V2412 (All versions < V2412.0012), Teamcenter Visualization V2506 (All versions < V2506.0009), Teamcenter Visualization V2512 (All versions < V2512.2605), Tecnomatix Plant Simulation V2404 (All versions < V2404.0022), Tecnomatix Plant Simulation V2504 (All versions < V2504.0010), Tecnomatix Process Simulate (All versions < V2606). Untrusted search path in IAM Client SDK may allow an authenticated user to potentially enable escalation of privilege via local access. |
| A vulnerability has been identified in SIMATIC S7-PLCSIM Advanced (All versions). Affected devices do not properly handle high-volume multicast network traffic, which can exhaust available memory resources in the affected application. This could allow an unauthenticated attacker on the local network segment to cause a denial-of-service condition of the affected application. The affected application becomes inaccessible and requires a manual restart; no project data is lost. Successful exploitation requires a specific project configuration to be already active on the targeted instance. |
| A vulnerability has been identified in Opcenter X (All versions < V2604). Affected applications do not properly validate the algorithm specified in the JSON Web Token (JWT) header.
This could allow an unauthenticated remote attacker to forge arbitrary JWT, bypass authentication mechanisms and impersonate any user including administrative accounts, potentially gaining full unauthorized access to the application. |
| A flaw was found in 389 Directory Server. An unauthenticated remote attacker can inject LDAP search filters into the CleanAllRUV replication status-check extended operation. Because the handler performs the search against cn=config with elevated replication plugin privileges and returns a boolean match result, the attacker can extract sensitive server configuration metadata, including replication bind DNs and password storage scheme information. |
| A stack buffer overflow flaw was found in 389 Directory Server (389-ds-base). The get_ruvelement_from_berval() function in repl5_ruv.c copies digit characters from a network-supplied RUV berval into a fixed 16-byte stack buffer without bounds checking. A remote unauthenticated attacker can crash the LDAP server by sending a crafted StartNSDS50ReplicationRequest extended operation containing a replica ID field with more than 16 digit characters. The overflow occurs during payload decoding, before any authorization check. Stack protectors limit impact to denial of service. |
| A flaw was found in Red Hat Advanced Cluster Security for Kubernetes (RHACS). When processing Kubernetes Deployments, ACS replaces deployment identity metadata based on the openshift.io/encoded-deployment-config label. A user with permission to create Deployments can set this label to "null", causing ACS to treat the workload as having empty UID, name and labels and namespace "default". This bypasses deploy-time policy detection and enforcement visibility, prevents correct persistence in Central and breaks violation reporting and compliance correlation for the affected deployment. |
| The MailPress plugin for WordPress is vulnerable to unauthorized access in versions up to, and including, 1.5.0 via the campaign revision-restore REST endpoint (POST /wp-json/mailpress/v1/campaign/<id>/restore-revision/<revision_id>). The route in the vulnerable range was registered without a permissionCallback, allowing the restoreRevision() handler to run for unauthenticated requests and overwrite a campaign's content_html with any prior revision. This makes it possible for unauthenticated attackers to modify campaign content by restoring an arbitrary revision. |
| The MailerPress – Newsletter, email marketing & AI automation plugin for WordPress is vulnerable to unauthorized access due to a missing capability check on the `mailerpress/v1/contact` endpoint in all versions up to, and including, 1.5.0. This makes it possible for unauthenticated attackers to update contact details. |
| The BuddyPress WordPress plugin before 14.5.0 does not properly enforce authorization on its private messaging endpoints, allowing any authenticated user (Subscriber+) to read, modify, or delete other users' private messages. |
| The WP Go Maps WordPress plugin before 10.1.04 does not properly sanitise and escape a parameter before using it in a SQL query, allowing unauthenticated users to perform SQL injection attacks. |
| The GiveWP WordPress plugin before 4.16.3 does not properly restrict access to a REST API endpoint that returns recurring-donation records, allowing unauthenticated users to retrieve information about anonymous recurring donors, including their name and subscription details. |
| The Ultimate Member WordPress plugin before 2.12.1 does not filter administrator-level capabilities from the roles it makes selectable on its registration forms, and its post-registration safeguard against elevated accounts is disabled by default, allowing unauthenticated users to register with a site-defined role that carries administrator capabilities and gain administrative access, when such a role exists and a role-selection field is present on a published registration form. |
| The Academy LMS WordPress plugin through 3.8.2 does not restrict access to quiz attempt records to their owner, allowing any authenticated user with subscriber-level access and above (enrolled in any single course) to read every user's quiz attempts across the whole site, including personal data such as IP addresses, names, registration dates and quiz results. |
| The Realtyna Organic IDX plugin for WordPress is vulnerable to Arbitrary File Upload in versions up to, and including, 5.3.0. This is due to missing file extension and content validation in the saveLiveImages() function combined with an insufficient authorization check on the get_keys() AJAX handler and a missing authentication check on the REST API import endpoint. This makes it possible for authenticated attackers, with subscriber-level access and above, to upload arbitrary files on the affected site's server which may make remote code execution possible. |
| A provisioning script used when installing HIPASE-250 (formerly 250
SCALA) engineering workstations sets a fixed, hard-coded x11vnc
password. Because the same credential is applied to every workstation
provisioned this way, an attacker with adjacent-network access who
knows the password can gain VNC access to affected workstations. |
| The HTTP server component of ANDRITZ HIPASE-250 (formerly 250 SCALA)
in affected versions exposes an undocumented endpoint that changes
the server's logging level and target without requiring
authentication. A remote, unauthenticated attacker with network
access to the service may suppress audit logging, potentially
concealing other activity on the system. |